16 resultados para SIMULATED BODY-FLUIDS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past two decades, chiral capillary electrophoresis (CE) emerged as a promising, effective and economic approach for the enantioselective determination of drugs and their metabolites in body fluids, tissues and in vitro preparations. This review discusses the principles and important aspects of CE-based chiral bioassays, provides a survey of the assays developed during the past 10 years and presents an overview of the key achievements encountered in that time period. Applications discussed encompass the pharmacokinetics of drug enantiomers in vivo and in vitro, the elucidation of the stereoselectivity of drug metabolism in vivo and in vitro, and bioanalysis of drug enantiomers of toxicological, forensic and doping interest. Chiral CE was extensively employed for research purposes to investigate the stereoselectivity associated with hydroxylation, dealkylation, carboxylation, sulfoxidation, N-oxidation and ketoreduction of drugs and metabolites. Enantioselective CE played a pivotal role in many biomedical studies, thereby providing new insights into the stereoselective metabolism of drugs in different species which might eventually lead to new strategies for optimization of pharmacotherapy in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: There is a high frequency of diarrhea and vomiting in childhood. As a consequence the focus of the present review is to recognize the different body fluid compartments, to clinically assess the degree of dehydration, to know how the equilibrium between extracellular fluid and intracellular fluid is maintained, to calculate the effective blood osmolality and discuss both parenteral fluid requirments and repair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the ranges of Hounsfield unit (HU) found in body fluids, putrefaction fluids, and blood on postmortem CT and how these ranges are affected by postmortem interval, temperatures, and CT beam energy. Body fluids, putrefaction fluids, and blood from a total of 53 corpses were analyzed to determine the ranges of HU values from postmortem CT images that were taken prior to autopsy. The fluids measured in CT images were obtained at autopsy and examined in terms of macroscopic and microscopic appearances. Body fluids and blood were also collected in plastic bottles, which were subjected to CT scans at different beam energies (80-130 kV) and at various fluid temperatures (4 to 40 °C). At a postmortem interval of 1 to 4 days, the ranges of HU values of the serous fluids (13-38 HU) and the nonsedimented blood (40-88 HU) did not overlap. In the sedimented blood, the upper serum layer exhibited HU value ranges that overlapped with those of the serous fluids. The putrefaction fluids exhibited a range of HU values between 80 and -130 HU. Elevated HU values were observed in fluids with accretive cell impurities. HU values decreased slightly with increasing temperature and CT beam energy. We concluded that serous fluids and blood in fresh corpses can be characterized and differentiated from each other based on HU value ranges. In contrast, body fluids in decomposed corpses cannot be differentiated by their HU value ranges. Different beam energies and corpse temperatures had only minor influences on HU value ranges and therefore should not be obstacles to the differentiation and characterization of body fluids and blood.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background During production and processing of multi-walled carbon nanotubes (MWCNTs), they may be inhaled and may enter the pulmonary circulation. It is essential that interactions with involved body fluids like the pulmonary surfactant, the blood and others are investigated, particularly as these interactions could lead to coating of the tubes and may affect their chemical and physical characteristics. The aim of this study was to characterize the possible coatings of different functionalized MWCNTs in a cell free environment. Results To simulate the first contact in the lung, the tubes were coated with pulmonary surfactant and subsequently bound lipids were characterized. The further coating in the blood circulation was simulated by incubating the tubes in blood plasma. MWCNTs were amino (NH2)- and carboxyl (-COOH)-modified, in order to investigate the influence on the bound lipid and protein patterns. It was shown that surfactant lipids bind unspecifically to different functionalized MWCNTs, in contrast to the blood plasma proteins which showed characteristic binding patterns. Patterns of bound surfactant lipids were altered after a subsequent incubation in blood plasma. In addition, it was found that bound plasma protein patterns were altered when MWCNTs were previously coated with pulmonary surfactant. Conclusions A pulmonary surfactant coating and the functionalization of MWCNTs have both the potential to alter the MWCNTs blood plasma protein coating and to determine their properties and behaviour in biological systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The strength decrease in magnesium implants was studied in vitro and in vivo, with and without a protective plasmaelectrolytic coating. In vivo, degradation was examined by implanting rectangular plates on top of the nasal bone of miniature pigs. The presence of gas pockets in the soft tissue surrounding the implants was evaluated with intermediate X-rays and computed X-ray tomography scans before euthanasia. After 12 and 24weeks of in vivo degradation, the large rectangular plates were removed and mechanically tested in three-point bending. In vitro, identical plates were immersed in simulated body fluid for 4, 8 and 12weeks. In vitro and in vivo results showed that onset of gas release can be delayed by the plasmaelectrolytic coating. Mass loss and strength retention during in vivo degradation is about four times slower than during in vitro degradation for the chosen test conditions. Despite the slow degradation of the investigated WE43 alloy, the occurrence of gas pockets could not be completely avoided. Nevertheless, uniformity of degradation and reliable strength retention make this alloy a prime candidate for the use of magnesium in cranio-maxillofacial surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CE with multiple isomer sulfated beta-CD as the chiral selector was assessed for the simultaneous analysis of the enantiomers of ketamine and metabolites in extracts of equine plasma and urine. Different lots of the commercial chiral selector provided significant changes in enantiomeric ketamine separability, a fact that can be related to the manufacturing variability. A mixture of two lots was found to provide high-resolution separations and interference-free detection of the enantiomers of ketamine, norketamine, dehydronorketamine, and an incompletely identified hydroxylated metabolite of norketamine in liquid/liquid extracts of the two body fluids. Ketamine, norketamine, and dehydronorketamine could be unambiguously identified via HPLC fractionation of urinary extracts and using LC-MS and LC-MS/MS with 1 mmu mass discrimination. The CE assay was used to characterize the stereoselectivity of the compounds' enantiomers in the samples of five ponies anesthetized with isoflurane in oxygen and treated with intravenous continuous infusion of racemic ketamine. The concentrations of the ketamine enantiomers in plasma are equal, whereas the urinary amount of R-ketamine is larger than that of S-ketamine. Plasma and urine contain higher S- than R-norketamine levels and the mean S-/R-enantiomer ratios of dehydronorketamine in plasma and urine are lower than unity and similar.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aldosterone is a key regulator of electrolyte and water homeostasis and plays a central role in blood pressure regulation. Hormonal changes during pregnancy, among them increased progesterone and aldosterone production, lead to the required plasma volume expansion of the maternal body as an accommodation mechanism for fetus growth. This review discusses the regulation of aldosterone production by aldosterone synthase (CYP11B2); the impact on aldosterone secretion due to the presence of a chimeric gene originating from a crossover between CYP11B1 and CYP11B2 in glucocorticoid remediable aldosteronism (GRA) - the inherited form of hypertension; enhanced aldosterone production in aldosterone-producing adenoma (APA); and idiopathic hyperaldosteronism (IHA). Features of hyperaldosteronism are also found in patients with apparent mineralocorticoid excess (AME), in which glucocorticoids exacerbate activation of the mineralocorticoid receptor (MR) because of a defect in the 11beta-hydroxysteroid dehydrogenase type 2 enzyme. Regulation of aldosterone production and tissue-specific activation of the mineralocorticoid receptor are prerequisites for optimal control of body fluids and blood pressure during pregnancy and contribute largely to the wellbeing of the mother-to-be.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A comprehensive genetic analysis of 60 Mycoplasma sp. bovine group 7 isolates from different geographic origins and epidemiological settings is presented. Twenty-four isolates were recovered from the joints of calves during sporadic episodes of polyarthritis in geographically distinct regions of Queensland and New South Wales, Australia, including two clones of the type strain PG5O. A further three Australian isolates were also recovered from the tympanic bulla, retropharyngeal lymph node and the lung and another three isolates had unconfirmed histories. Six isolates originated from Germany, Portugal, Nigeria, and France. Twenty-four epidemiologically related isolates of Mycoplasma sp. bovine group 7 were recovered from multiple tissue sites and body fluids of infected calves with polyarthritis, mastitic milk, and from the stomach contents, lung and liver from aborted foetuses in three large, centrally managed dairy herds in New South Wales, Australia. Restriction endonuclease analysis (REA) of genomic DNA differentiated 29 Cfol profiles among these 60 isolates and grouped all 24 epidemiologically related isolates in a defined pattern showing a clonal origin. Three isolates of this clonal cluster were recovered from mastitic milk and the synovial exudate of clinically-affected calves and appeared sporadically for periods up to 18 months after the initial outbreak of polyarthritis indicating a persistent, close association of the organism with cattle in these herds. The Cfol profile representative of the clonal cluster was distinguishable from profiles of isolates recovered from multiple, unrelated cases of polyarthritis in Queensland and New South Wales and from other countries. All 24 isolates from the clonal cluster possessed a plasmid (pBG7AU) with a molecular size of 1022 bp. DNA sequence analysis of pBG7AU identified two open reading frames sharing 81 and 99% DNA sequence similarity with hypothetical replication control proteins A and B respectively, previously described in plasmid pADB201 isolated from M. mycoides subspecies mycoides. Other isolates of bovine group 7, epidemiologically unrelated to the clonal cluster, including two clones of the type strain PG5O, possessed a similar-sized plasmid. These data confirm that Mycoplasma sp. bovine group 7 is capable of migrating to, and multiplying within, different tissue sites within a single animal and among different animals within a herd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Control of metabolic pathways is a major task of the somatotropic axis and its constituents. Insulinlike growth-factor binding proteins (IGFBPs) bind IGF-I and -II and act as carriers and regulators of their activities in blood, body fluids and tissues. Over two periods of physiological adaptation, this study investigated the binding pattern of IGF-I to IGFBPs in the plasma of 50 multiparous Holstein dairy cows and identified relationships with the hepatic mRNA abundance of IGFBPs and plasma IGF-I during the lactational negative energy balance (NEB) and during a deliberately induced NEB by feed restriction. Period 1 lasted from week 3 antepartum (a.p.) to week 12 postpartum (p.p.) and period 2, the period of feed restriction, started at around 100 DIM and lasted for three weeks with a control (C) and a restricted group (R). Blood samples and liver biopsies were collected in week 3 a.p., and in weeks 1 and 4 p.p. of period 1 and in weeks 0 and 3 of period 2. For column chromatography of IGFBPs, plasma samples of all animals were pooled by group and time points of sampling. Plasma IGF-I dropped from week 3 a.p. to week 1 p.p. and thereafter increased until week 0 (period 2) and did not change up to week 3 of period 2. The binding of IGF-I to plasma IGFBP-1 and -2 increased in period 1 from week 3 a.p. to week 4 p.p., while at the same time it decreased for IGFBP-3. During period 2, the binding of IGF-I to plasma IGFBP-1 and -2 decreased for both groups, but less for R cows. In C cows, the IGF-I binding to IGFBP-3 in plasma increased from week 0 to week 3 of period 2, whereas R cows showed a slight decrease. In period 1, hepatic mRNA abundance of IGFBP-3 followed the plasma IGFBP-3 binding in contrast to the mRNA abundances of IGFBP-1 and -2. The latter increased from week 3 a.p. to week 1 p.p. and decreased afterwards whereas IGF-I binding to IGFBP-1 and -2 increased. In week 3 of period 2, the binding of IGF-I to IGFBP-1 and -2 and their hepatic mRNA abundance were higher in R cows compared to C cows. Hepatic mRNA abundance of IGF-I was consistently positively correlated with plasma IGF-I, especially pronounced during the NEBs in week 1 p.p. (period 1) and in week 3 (period 2) in R cows. While no distinct relation between mRNA abundance of IGFBP-1 and plasma IGF-I was evident, the mRNA abundance of IGFBP-2 was inversely related to plasma IGF-I over all experimental time points independent of treatment. The mRNA abundance of IGFBP-3 was particularly correlated with plasma IGF-I during the 2 experimental stages of a NEB. Obviously IGFBP-3, but not IGFBP-1 and -2, binding in plasma closely followed the respective pattern of hepatic mRNA abundance during the entire experimental period. The fact that changes in the different plasma IGFBPs during altering metabolic stages in different stages of lactation do not always strictly follow their mRNA abundance in liver suggests tissues other than the liver flexibly contributing to the IGFBP pool in plasma as well as a partially post-transcriptional regulation of IGFBP synthesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Work dealing with the monitoring of alcohol markers by CE performed during the past two decades led to the development of assays for carbohydrate-deficient transferrin (CDT), ethyl sulfate, ethyl glucuronide, and phosphatidylethanol in body fluids and first attempts for the detection of the urinary 5-hydroxytryptophol/5-hydroxyindoleacetic acid ratio and stable hemoglobin acetaldehyde adducts. Most notably are assays for CDT that have been commercialized and are being used in many laboratories under routine conditions. This paper provides insight into the development, specifications, and use of the currently known CE-based assays suitable to detect alcohol markers. The achievements reached so far indicate that CE is an attractive technology for monitoring alcohol markers. This is particularly seen with the CDT assays that do not require an elaborate sample pretreatment and thus could be fully automated for high-throughput analyses on multicapillary instruments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To measure nitric oxide (NO) concentrations in serum, urine, and synovial fluid (SF) of dogs with naturally occurring cranial cruciate ligament (CCL) rupture and normal dogs, and to compare these with clinical and histologic changes of osteoarthritis (OA). STUDY DESIGN Prospective clinical study including 2 groups of animals selected from the hospital population. ANIMALS Forty-three dogs (CCL group) with OA secondary to CCL rupture; 30 healthy dogs (control group) without CCL rupture. METHODS Serum, urine, and SF were collected before and during surgery in the CCL group or immediately after euthanasia in the control group. Articular cartilage and synovial membrane tissue specimens were prepared for routine histologic examination. The stable end products of NO, total nitrite and nitrate (NOt) activity, were measured in body fluids and compared with macroscopic and histologic degrees of OA. Urinary NOt concentration was compared with urinary creatinine concentration and stated as urinary NOt:creatinine ratio (UNCR). RESULTS-SF NOt concentrations were not significantly different between the 2 groups. Serum NOt concentrations (45.6 vs 28.9 micromol/L; P =.042) and the UNCR (0.007 vs 0.004; P =.035) were significantly higher in dogs of the CCL group compared with the control population. An association between UNCR and histologic and macroscopical OA grades could be demonstrated. CONCLUSION UNCR might be a useful indicator of nitrite and nitrate production and, therefore, osteoarthritic changes in joints. CLINICAL RELEVANCE UNCR could be used as a tool to evaluate the NOt production by joint tissues over time and might therefore provide a method of evaluating the effects of drugs in the control of osteoarthritis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Circulating miRNAs in body fluids, particularly serum, are promising candidates for future routine biomarker profiling in various pathologic conditions in human and veterinary medicine. However, reliable standardized methods for miRNA extraction from equine serum and fresh or archived whole blood are sorely lacking. We systematically compared various miRNA extraction methods from serum and whole blood after short and long-term storage without addition of RNA stabilizing additives prior to freezing. Time of storage at room temperature prior to freezing did not affect miRNA quality in serum. Furthermore, we showed that miRNA of NGS-sufficient quality can be recovered from blood samples after >10 years of storage at -80 °C. This allows retrospective analyses of miRNAs from archived samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.