205 resultados para Reatividade vascular
Resumo:
Our previous data suggested that angiopoietin-2 (Ang-2) is linked to pericyte loss, thereby playing an important role in diabetic retinopathy. In this study, we investigated the effect of retinal overexpression of human Ang-2 (mOpsinhAng2 mouse) on vascular morphology in non-diabetic and streptozotozin-induced diabetic animals. Pericyte (PC) coverage and acellular capillary (AC) formation were quantitated in retinal digest preparations after 3 and 6 months of diabetes duration. The degree of retinopathy in non-diabetic mOpsinhAng2 mice at 3 months (-21% PC, +49% AC) was comparable to age-matched diabetic wild type mice. Diabetic mOpsinhAng2 mice exhibited significantly worse vascular pathology than wild type counterparts at 6 months. Quantitative PCR revealed that human Ang-2 mRNA was highly overexpressed in retinas of transgenic mice. Our data demonstrate that overexpression of Ang-2 in the retina enhances vascular pathology, indicating that Ang-2 plays an essential role in diabetic vasoregression via destabilization of pericytes.
Resumo:
In addition to the increasingly significant role of multislice computed tomography in forensic pathology, the performance of whole-body computed tomography angiography provides outstanding results. In this case, we were able to detect multiple injuries of the parenchymal organs in the upper abdomen as well as lesions of the brain parenchyma and vasculature of the neck. The radiologic findings showed complete concordance with the autopsy and even supplemented the autopsy findings in areas that are difficult to access via a manual dissection (such as the vasculature of the neck). This case shows how minimally invasive computed tomography angiography can serve as an invaluable adjunct to the classic autopsy procedure.
Resumo:
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.
Resumo:
To report the use of the second-generation Amplatzer Vascular Plug II (AVP II) for the treatment of a posttraumatic type A carotid-cavernous fistula (CCF).
Resumo:
Delayed occlusion time in parent artery occlusion of brain-supplying vessels might carry risk for thromboembolic complications. Vascular plug devices are successfully used in cardiopulmonary and peripheral interventions to occlude high-flow lesions and have been adapted for use in neurointerventions. The purpose of the present study was to experimentally evaluate the immediate occlusion time of the AMPLATZER vascular plug (AVP) II-a second-generation cylindrical, self-expandable, resheathable nitinol wire mesh consisting of three lobes-in the carotid artery.
Resumo:
BACKGROUND: Peripheral artery disease (PAD) is common and imposes a high risk of major systemic and limb ischemic events. The REduction of Atherothrombosis for Continued Health (REACH) Registry is an international prospective registry of patients at risk of atherothrombosis caused by established arterial disease or the presence of 3 atherothrombotic risk factors. METHODS AND RESULTS: We compared the 2-year rates of vascular-related hospitalizations and associated costs in US patients with established PAD across patient subgroups. Symptomatic PAD at enrollment was identified on the basis of current intermittent claudication with an ankle-brachial index (ABI) <0.90 or a history of lower-limb revascularization or amputation. Asymptomatic PAD was diagnosed on the basis of an enrollment ABI <0.90 in the absence of symptoms. Overall, 25 763 of the total 68 236-patient REACH cohort were enrolled from US sites; 2396 (9.3%) had symptomatic and 213 (0.8%) had asymptomatic PAD at baseline. One- and cumulative 2-year follow-up data were available for 2137 (82%) and 1677 (64%) of US REACH patients with either symptomatic or asymptomatic PAD, respectively. At 2 years, mean cumulative hospitalization costs, per patient, were $7445, $7000, $10 430, and $11 693 for patients with asymptomatic PAD, a history of claudication, lower-limb amputation, and revascularization, respectively (P=0.007). A history of peripheral intervention (lower-limb revascularization or amputation) was associated with higher rates of subsequent procedures at both 1 and 2 years. CONCLUSIONS: The economic burden of PAD is high. Recurring hospitalizations and repeat revascularization procedures suggest that neither patients, physicians, nor healthcare systems should assume that a first admission for a lower-extremity PAD procedure serves as a permanent resolution of this costly and debilitating condition.
Resumo:
The acetabular labrum plays an important role in hip joint stability and protection of the articular cartilage of the hip. Despite this, few investigators have evaluated its microscopic vasculature and, to our knowledge, none has assessed its macroscopic blood supply. The purposes of this study were to identify the origin and course of the vascular supply to the acetabular labrum to determine if this blood supply is affected by a labral tear.
Resumo:
Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure.
Resumo:
Adverse events in utero may predispose to cardiovascular disease in adulthood. The underlying mechanisms are unknown. During preeclampsia, vasculotoxic factors are released into the maternal circulation by the diseased placenta. We speculated that these factors pass the placental barrier and leave a defect in the circulation of the offspring that predisposes to a pathological response later in life. The hypoxia associated with high-altitude exposure is expected to facilitate the detection of this problem.
Resumo:
The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT).
Resumo:
The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.
Resumo:
The aim of this study was to assess the differences in terms of curvature and angulation of the treated vessel after the deployment of either a metallic stent or a polymeric scaffold device.
Resumo:
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.
Resumo:
The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction.