20 resultados para PHOTON IMAGING CAMERA
Resumo:
We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.
Resumo:
PURPOSE Despite different existing methods, monitoring of free muscle transfer is still challenging. In the current study we evaluated our clinical setting regarding monitoring of such tissues, using a recent microcirculation-imaging camera (EasyLDI) as an additional tool for detection of perfusion incompetency. PATIENTS AND METHODS This study was performed on seven patients with soft tissue defect, who underwent reconstruction with free gracilis muscle. Beside standard monitoring protocol (clinical assessment, temperature strips, and surface Doppler), hourly EasyLDI monitoring was performed for 48 hours. Thereby a baseline value (raised flap but connected to its vascular bundle) and an ischaemia perfusion value (completely resected flap) were measured at the same point. RESULTS The mean age of the patients, mean baseline value, ischaemia value perfusion were 48.00 ± 13.42 years, 49.31 ± 17.33 arbitrary perfusion units (APU), 9.87 ± 4.22 APU, respectively. The LDI measured values in six free muscle transfers were compatible with hourly standard monitoring protocol, and normalized LDI values significantly increased during time (P < 0.001, r = 0.412). One of the flaps required a return to theatre 17 hours after the operation, where an unsalvageable flap loss was detected. All normalized LDI values of this flap were under the ischaemia perfusion level and the trend was significantly descending during time (P < 0.001, r = -0.870). CONCLUSION Due to the capability of early detection of perfusion incompetency, LDI may be recommended as an additional post-operative monitoring device for free muscle flaps, for early detection of suspected failing flaps and for validation of other methods.
Resumo:
During the generalization of epileptic seizures, pathological activity in one brain area recruits distant brain structures into joint synchronous discharges. However, it remains unknown whether specific changes in local circuit activity are related to the aberrant recruitment of anatomically distant structures into epileptiform discharges. Further, it is not known whether aberrant areas recruit or entrain healthy ones into pathological activity. Here we study the dynamics of local circuit activity during the spread of epileptiform discharges in the zero-magnesium in vitro model of epilepsy. We employ high-speed multi-photon imaging in combination with dual whole-cell recordings in acute thalamocortical (TC) slices of the juvenile mouse to characterize the generalization of epileptic activity between neocortex and thalamus. We find that, although both structures are exposed to zero-magnesium, the initial onset of focal epileptiform discharge occurs in cortex. This suggests that local recurrent connectivity that is particularly prevalent in cortex is important for the initiation of seizure activity. Subsequent recruitment of thalamus into joint, generalized discharges is coincident with an increase in the coherence of local cortical circuit activity that itself does not depend on thalamus. Finally, the intensity of population discharges is positively correlated between both brain areas. This suggests that during and after seizure generalization not only the timing but also the amplitude of epileptiform discharges in thalamus is entrained by cortex. Together these results suggest a central role of neocortical activity for the onset and the structure of pathological recruitment of thalamus into joint synchronous epileptiform discharges.
Resumo:
The histological status of the sentinel lymph node (SLN) is one of the most relevant prognostic factors for the overall survival of patients with cutaneous malignancies, independent of tumour depth of the primary tumour.
Resumo:
AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.
Resumo:
Imaging of biological samples has been performed with a variety of techniques for example electromagnetic waves, electrons, neutrons, ultrasound and X-rays. Also conventional X-ray imaging represents the basis of medical diagnostic imaging, it remains of limited use in this application because it is based solely on the differential absorption of X-rays by tissues. Coherent and bright photon beams, such as those produced by third-generation synchrotron X-ray sources, provide further information on subtle X-ray phase changes at matter interfaces. This complements conventional X-ray absorption by edge enhancement phenomena. Thus, phase contrast imaging has the potential to improve the detection of structures on images by detecting those structures that are invisible with X-ray absorption imaging. Images of a weakly absorbing nylon fibre were recorded in in-line holography geometry using a high resolution low-noise CCD camera at the ESRF in Grenoble. The method was also applied to improve image contrast for images of biological tissues. This paper presents phase contrast microradiographs of vascular tree casts and images of a housefly. These reveal very fine structures, that remain invisible with conventional absorption contrast only.
Resumo:
Deposition and clearance studies are used during product development and in fundamental research. These studies mostly involve radionuclide imaging, but pharmacokinetic methods are also used to assess the amount of drug absorbed through the lungs, which is closely related to lung deposition. Radionuclide imaging may be two-dimensional (gamma scintigraphy or planar imaging), or three-dimensional (single photon emission computed tomography and positron emission tomography). In October 2009, a group of scientists met at the "Thousand Years of Pharmaceutical Aerosols" conference in Reykjavik, Iceland, to discuss future research in key areas of pulmonary drug delivery. This article reports the session on "Deposition, imaging and clearance." The objective was partly to review our current understanding, but more importantly to assess "what remains to be done?" A need to standardize methodology and provide a regulatory framework by which data from radionuclide imaging methods could be compared between centers and used in the drug approval process was recognized. There is also a requirement for novel radiolabeling methods that are more representative of production processes for dry powder inhalers and pressurized metered dose inhalers. A need was identified for studies to aid our understanding of the relationship between clinical effects and regional deposition patterns of inhaled drugs. A robust methodology to assess clearance from small conducting airways should be developed, as a potential biomarker for therapies in cystic fibrosis and other diseases. The mechanisms by which inhaled nanoparticles are removed from the lungs, and the factors on which their removal depends, require further investigation. Last, and by no means least, we need a better understanding of patient-related factors, including how to reduce the variability in pulmonary drug delivery, in order to improve the precision of deposition and clearance measurements.
Resumo:
The low-energy β− emitter 161Tb is very similar to 177Lu with respect to half-life, beta energy and chemical properties. However, 161Tb also emits a significant amount of conversion and Auger electrons. Greater therapeutic effect can therefore be expected in comparison to 177Lu. It also emits low-energy photons that are useful for gamma camera imaging. The 160Gd(n,γ)161Gd→161Tb production route was used to produce 161Tb by neutron irradiation of massive 160Gd targets (up to 40 mg) in nuclear reactors. A semiautomated procedure based on cation exchange chromatography was developed and applied to isolate no carrier added (n.c.a.) 161Tb from the bulk of the 160Gd target and from its stable decay product 161Dy. 161Tb was used for radiolabeling DOTA-Tyr3-octreotate; the radiolabeling profile was compared to the commercially available n.c.a. 177Lu. A 161Tb Derenzo phantom was imaged using a small-animal single-photon emission computed tomography camera. Up to 15 GBq of 161Tb was produced by long-term irradiation of Gd targets. Using a cation exchange resin, we obtained 80%–90% of the available 161Tb with high specific activity, radionuclide and chemical purity and in quantities sufficient for therapeutic applications. The 161Tb obtained was of the quality required to prepare 161Tb–DOTA-Tyr3-octreotate. We were able to produce 161Tb in n.c.a. form by irradiating highly enriched 160Gd targets; it can be obtained in the quantity and quality required for the preparation of 161Tb-labeled therapeutic agents.
Resumo:
The synthesis of a photolabile derivative of inositol-1,4,5-trisphosphate (IP3) is described. This new caged second messenger (6-ortho-nitroveratryl)-IP3 (6-NV-IP3) has an extinction coefficient of 5000 M(-1) cm(-1) at 350 nm, and a quantum yield of photolysis of 0.12. Therefore, 6-NV-IP3 is photolyzed with UV light about three times more efficiently than the widely used P(4(5))-1-(2-nitrophenyl)ethyl-caged IP3 (NPE-IP3). 6-NV-IP3 has a two-photon cross-section of about 0.035 GM at 730 nm. This absorbance is sufficiently large for effective two-photon excitation in living cells at modest power levels. Using near-IR light (5 mW, 710 nm, 80 MHz, pulse-width 70 fs), we produced focal bursts of IP3 in HeLa cells, as revealed by laser-scanning confocal imaging of intracellular Ca2+ concentrations. Therefore, 6-NV-IP3 can be used for efficient, subcellular photorelease of IP3, not only in cultured cells but also, potentially, in vivo. It is in the latter situation that two-photon photolysis should reveal its true forte.
Resumo:
PURPOSE: It has been shown that some primary human tumours and their metastases, including prostate and breast tumours, overexpress gastrin-releasing peptide (GRP) receptors. Bombesin (BN) is a neuropeptide with a high affinity for these GRP receptors. We demonstrated successful scintigraphic visualisation of BN receptor-positive tumours in preclinical studies using the radiolabelled BN analogue [(111)In-DTPA-Pro(1),Tyr(4)]BN. However, the receptor affinity as well as the serum stability of this analogue leave room for improvement. Therefore new (111)In-labelled BN analogues were synthesised and evaluated in vitro and in vivo. METHODS AND RESULTS: The receptor affinity of the new BN analogues was tested on human GRP receptor-expressing prostate tumour xenografts and rat colon sections. Analogues with high receptor affinity (low nM range) were selected for further evaluation. Incubation in vitro of GRP receptor-expressing rat CA20948 and human PC3 tumour cells with the (111)In-labelled analogues resulted in rapid receptor-mediated uptake and internalisation. The BN analogue with the best receptor affinity and in vitro internalisation characteristics, Cmp 3 ([(111)In-DTPA-ACMpip(5),Tha(6),betaAla(11),Tha(13),Nle(14)]BN(5-14)), was tested in vivo in biodistribution studies using rats bearing GRP receptor-expressing CA20948 tumours, and nude mice bearing human PC3 xenografts. Injection of (111)In-labelled Cmp 3 in these animals showed high, receptor-mediated uptake in receptor-positive organs and tumours which could be visualised using planar gamma camera and microSPECT/CT imaging. CONCLUSION: With their enhanced receptor affinity and their rapid receptor-mediated internalisation in vitro and in vivo, the new BN analogues, and especially Cmp 3, are promising candidates for use in diagnostic molecular imaging and targeted radionuclide therapy of GRP receptor-expressing cancers.
Resumo:
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.
Resumo:
The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.
Resumo:
OBJECTIVES: To evaluate the feasibility of fusion imaging compound tomography (FICT) of CT/MRI and single photon emission tomography (SPECT) versus planar scintigraphy only (plSc) in pre-surgical staging for vulvar cancer. MATERIALS AND METHODS: Analysis of consecutive patients with vulvar cancer who preoperatively underwent sentinel scintigraphy (planar and 3D-SPECT imaging) and CT or MRI. Body markers were used for exact anatomical co-registration and fusion datasets were reconstructed using SPECT and CT/MRI. The number and localisation of all intraoperatively identified and resected sentinel lymph nodes (SLN) were compared between planar and 3D fusion imaging. RESULTS: Twenty six SLN were localized on planar scintigraphy. Twelve additional SLN were identified after SPECT and CT/MRI reconstruction, all of them were confirmed intraoperatively. In seven cases where single foci were identified at plSc, fusion imaging revealed grouped individual nodes and five additional localisations were discovered at fusion imaging. In seven patients both methods identified SLN contra lateral to the primary tumor site, but only fusion imaging allowed to localise iliac SLN in four patients. All SLN predicted on fusion imaging could be localised and resected during surgery. CONCLUSIONS: Fusion imaging using SPECT and CT/MRI can detect SLN in vulvar cancer more precisely than planar imaging regarding number and anatomical localisation. FICT revealed additional information in seven out of ten cases (70%).