59 resultados para Month
Resumo:
OBJECTIVE: To determine the prevalence and independent predictors of significant atherosclerotic renal artery stenosis (RAS) in unselected hypertensive patients undergoing coronary angiography and to assess the 6-month outcome of those patients with a significant RAS. METHODS: One thousand, four hundred and three consecutive hypertensive patients undergoing drive-by renal arteriography were analyzed retrospectively. Univariate and multivariate logistic regression analyses were performed to identify independent predictors of RAS. In patients with significant RAS (>or=50% luminal narrowing), 6-month follow-up was assessed and outcome was compared between patients with or without renal revascularization. RESULTS: The prevalence of significant RAS was 8%. After multivariate analysis, coronary [odds ratio 5.3; 95% confidence interval (CI) 2.7-10.3; P < 0.0001], peripheral (odds ratio 3.3; 95% CI 2.0-5.5; P < 0.0001), and cerebral artery (odds ratio 2.8; 95% CI 1.5-5.3; P = 0.001) diseases, and impaired renal function (odds ratio 2.9; 95% CI 1.8-4.5; P < 0.0001) were found as independent predictors. At least one of these predictors was present in 96% of patients with RAS. In 74 patients (66%) with significant RAS, an ad hoc revascularization was performed. At follow-up, creatinine clearance was significantly higher in revascularized than in nonrevascularized patients (69.2 vs. 55.5 ml/min per 1.73 m, P = 0.029). By contrast, blood pressure was comparable between both groups, but nonrevascularized patients were taking significantly more antihypertensive drugs as compared with baseline (2.7 vs. 2.1, follow-up vs. baseline; P = 0.0066). CONCLUSION: The prevalence of atherosclerotic RAS in unselected hypertensive patients undergoing coronary angiography was low. Coronary, peripheral, and cerebral artery diseases, and impaired renal function were independent predictors of RAS. Ad hoc renal revascularization was associated with better renal function and fewer intake of antihypertensive drugs at follow-up.
Resumo:
The expression of vascular endothelial growth factor (VEGF) is elevated in diabetic macular edema (DME). Ranibizumab binds to and inhibits multiple VEGF variants. We investigated the safety and efficacy of ranibizumab in DME involving the foveal center.
Resumo:
The purpose of this study is to compare the healing of deep, non-contained intrabony defects (i.e., with a ?80% 1-wall component and a residual 2- to 3-wall component in the most apical part) treated with either an enamel matrix derivative (EMD) or guided tissue regeneration (GTR) after 12 months.
Resumo:
This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).
Resumo:
The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.
Resumo:
Novolimus, a macrocyclic lactone with anti-proliferative properties, has a similar efficacy to currently available agents; however it requires a lower dose, and less polymer, and is therefore conceivably safer.
Resumo:
The ACCESS trial examined the 12-month effectiveness of continuous therapeutic assertive community treatment (ACT) as part of integrated care compared to standard care in a catchment area comparison design in patients with schizophrenia spectrum disorders treated with quetiapine immediate release.
Resumo:
Intra-arterial thrombolysis can be used for treatment of basilar artery occlusion. Predictors of outcome before initiation of treatment are of special interest.
Resumo:
The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely for patients undergoing coronary surgery with at least one venous graft. Graft patency and clinical results were evaluated, respectively, at 6 months and 5 years after surgery.
Resumo:
Airway management for successful ventilation by laypersons and inexperienced healthcare providers is difficult to achieve. Bag-valve mask (BVM) ventilation requires extensive training and is performed poorly. Supraglottic airway devices (SADs) have been successfully introduced to clinical resuscitation practice as an alternative. We evaluated recently introduced (i-gel™ and LMA-Supreme™) and established SADs (LMA-Unique™, LMA-ProSeal™) and BVM used by laypeople in training sessions on manikins.
Resumo:
The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months.
Resumo:
We investigated the 6-month clinical outcomes after implantation of second-generation 3.0-mm bioresorbable everolimus-eluting vascular scaffolds (BVS) in small coronary vessels (<2.5 mm).
Resumo:
Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas–volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.
Resumo:
To compare the intravascular ultrasound virtual histology (IVUS-VH) appearance of the polymeric struts of the first (Revision 1.0) and the second (Revision 1.1) generation bioresorbable vascular scaffold (BVS).