228 resultados para MINIMALLY INVASIVE SURGICAL PROCEDURES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY QUESTION: What is the effect of the minimally invasive surgical treatment of endometriosis on health and on quality of work life (e.g. working performance) of affected women? SUMMARY ANSWER: Absence from work, performance loss and the general negative impact of endometriosis on the job are reduced significantly by the laparoscopic surgery. WHAT IS KNOWN ALREADY: The benefits of surgery overall and of the laparoscopic method in particular for treating endometriosis have been described before. However, previous studies focus on medical benchmarks without including the patient's perspective in a quantitative manner. STUDY DESIGN, SIZE, DURATION: A retrospective questionnaire-based survey covering 211 women with endometriosis and a history of specific laparoscopic surgery in a Swiss university hospital, tertiary care center. Data were returned anonymously and were collected from the beginning of 2012 until March 2013. PARTICIPANTS/MATERIALS, SETTING, METHODS: Women diagnosed with endometriosis and with at least one specific laparoscopic surgery in the past were enrolled in the study. The study investigated the effect of the minimally invasive surgery on health and on quality of work life of affected women. Questions used were obtained from the World Endometriosis Research Foundation (WERF) Global Study on Women's Health (GSWH) instrument. The questionnaire was shortened and adapted for the purpose of the present study. MAIN RESULTS AND THE ROLE OF CHANCE: Of the 587 women invited to participate in the study, 232 (232/587 = 40%) returned the questionnaires. Twenty-one questionnaires were excluded due to incomplete data and 211 sets (211/587 = 36%) were included in the study. Our data show that 62% (n = 130) of the study population declared endometriosis as influencing the job during the period prior to surgery, compared with 28% after surgery (P < 0.001). The mean (maximal) absence from work due to endometriosis was reduced from 2.0 (4.9) to 0.5 (1.4) hours per week (P < 0.001). The mean (maximal) loss in working performance after the surgery averaged out at 5.7% (12.6%) compared with 17.5% (30.5%) before this treatment (P < 0.001). LIMITATIONS, REASONS FOR CAUTION: The mediocre response rate of the study weakens the representativeness of the investigated population. Considering the anonymous setting a non-responder investigation was not performed. A bias due to selection, information and negativity effects within a retrospective survey cannot be excluded, although study-sensitive questions were provided in multiple ways. The absence of a control group (sham group; e.g. patients undergoing specific diagnostic laparoscopy without treatment) is a further limitation of the study. WIDER IMPLICATIONS OF THE FINDINGS: Our study shows that indicated minimally invasive surgery has a clear positive effect on the wellbeing and working performance of women suffering from moderate to severe endometriosis. Furthermore, national net savings in indirect costs with the present number of surgeries is estimated to be €10.7 million per year. In an idealized setting (i.e. without any diagnosis delay) this figure could be more than doubled. STUDY FUNDING/COMPETING INTERESTS: The study was performed on behalf of the University Hospital of Bern (Inselspital) as one of the leading Swiss tertiary care centers. The authors do not declare any competing interests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heavy menstrual bleeding (HMB) has significant adverse effects on the quality of life of many women, placing an economic burden on both health services and society at large. Thus, it is essential that all women with HMB have easy access to the proper diagnostic and therapeutic work-up in an outpatient fashion, avoiding the more time-consuming inpatient management. This new outpatient approach for HMB is one of the latest development of gynecological practice and can offer both diagnostic and therapeutic procedures. This manuscript aims to show the current possibilities of the modern management of HMB, which can be safely and effectively accomplished in the outpatient setting: global and directed endometrial biopsy, levonorgestrel intrauterine system insertion as well as minimally invasive surgical procedures (encompassing a variety of operative hysteroscopic procedures and second-generation endometrial ablation) are described below.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe (1) preoperative findings and surgical technique, (2) intraoperative difficulties, and (3) postoperative complications and long-term outcome of equine cheek tooth extraction using a minimally invasive transbuccal screw extraction (MITSE) technique. STUDY DESIGN: Retrospective case series. ANIMALS: Fifty-four equids; 50 horses, 3 ponies, and 1 mule. METHODS: Fifty-eight MITSE procedures were performed to extract cheek teeth in 54 equids. Peri- and intraoperative difficulties, as well as short- (<1 month) and long-term (>6 months) postoperative complications were recorded. Followup information was obtained through telephone interviews, making specific inquiries about nasal discharge, facial asymmetry, and findings consistent with surgical site infection. RESULTS: Preoperative findings that prompted exodontia included 50 cheek teeth with apical infections, 48 fractures, 4 neoplasia, 2 displacements, and 1 supernumerary tooth. Previous oral extraction was attempted but had failed in 55/58 (95%) animals because of cheek tooth fracture in 28, or insufficient clinical crown for extraction with forceps in 27. MITSE was successful in removing the entire targeted dental structure in 47/58 (81%) procedures. However, MITSE failed to remove the entire targeted dental structure in 11/58 (19%) procedures and was followed by repulsion in 10/11 (91%). Short-term postoperative complications included bleeding (4/58 procedures, 7%) and transient facial nerve paralysis (4/58 procedures, 7%). Owners were satisfied with the functional and cosmetic outcome for 40/41 (98%) animals with followup. CONCLUSION: MITSE offers an alternate for cheek tooth extraction in equids, where conventional oral extraction is not possible or has failed. Overall, there was low morbidity, which compares favorably with invasive buccotomy or repulsion techniques

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although postmortem CT suffices for diagnosing most forms of traumatic death, the examination of natural death is, to date, very difficult and error prone. The introduction of postmortem angiography has led to improved radiologic diagnoses of natural deaths. Nevertheless, histologic changes to tissues, an important aspect in traditional examination procedures, remain obscure even with CT and CT angiography. For this reason, we examined the accuracy of a minimally invasive procedure (i.e., CT angiography combined with biopsy) in diagnosing major findings and the cause of death in natural deaths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In a prospective, nonrandomized study the outcome in terms of rehabilitation and complications of total hip arthroplasty (THA) through a superior capsulotomy exposure (study group) was compared to THA performed through a direct lateral exposure (control group). PATIENTS AND METHODS: The study group (106 THA) and the control group (107 THA) were controlled for complexity and had no significant differences in age, sex, diagnosis, or body mass index. RESULTS: The study group had improved recovery at 6 weeks after surgery which was statistically significant (p<0.001). In addition, the study group had a lower incidence of perioperative complications. CONCLUSION: The current study demonstrates the potential that less-invasive surgical techniques with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with an accelerated recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Robotic assistance in the context of lateral skull base surgery, particularly during cochlear implantation procedures, has been the subject of considerable research over the last decade. The use of robotics during these procedures has the potential to provide significant benefits to the patient by reducing invasiveness when gaining access to the cochlea, as well as reducing intracochlear trauma when performing a cochleostomy. Presented herein is preliminary work on the combination of two robotic systems for reducing invasiveness and trauma in cochlear implantation procedures. A robotic system for minimally invasive inner ear access was combined with a smart drilling tool for robust and safe cochleostomy; evaluation was completed on a single human cadaver specimen. Access to the middle ear was successfully achieved through the facial recess without damage to surrounding anatomical structures; cochleostomy was completed at the planned position with the endosteum remaining intact after drilling as confirmed by microscope evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical robots have been proposed ex vivo to drill precise holes in the temporal bone for minimally invasive cochlear implantation. The main risk of the procedure is damage of the facial nerve due to mechanical interaction or due to temperature elevation during the drilling process. To evaluate the thermal risk of the drilling process, a simplified model is proposed which aims to enable an assessment of risk posed to the facial nerve for a given set of constant process parameters for different mastoid bone densities. The model uses the bone density distribution along the drilling trajectory in the mastoid bone to calculate a time dependent heat production function at the tip of the drill bit. Using a time dependent moving point source Green's function, the heat equation can be solved at a certain point in space so that the resulting temperatures can be calculated over time. The model was calibrated and initially verified with in vivo temperature data. The data was collected in minimally invasive robotic drilling of 12 holes in four different sheep. The sheep were anesthetized and the temperature elevations were measured with a thermocouple which was inserted in a previously drilled hole next to the planned drilling trajectory. Bone density distributions were extracted from pre-operative CT data by averaging Hounsfield values over the drill bit diameter. Post-operative [Formula: see text]CT data was used to verify the drilling accuracy of the trajectories. The comparison of measured and calculated temperatures shows a very good match for both heating and cooling phases. The average prediction error of the maximum temperature was less than 0.7 °C and the average root mean square error was approximately 0.5 °C. To analyze potential thermal damage, the model was used to calculate temperature profiles and cumulative equivalent minutes at 43 °C at a minimal distance to the facial nerve. For the selected drilling parameters, temperature elevation profiles and cumulative equivalent minutes suggest that thermal elevation of this minimally invasive cochlear implantation surgery may pose a risk to the facial nerve, especially in sclerotic or high density mastoid bones. Optimized drilling parameters need to be evaluated and the model could be used for future risk evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS To determine efficacy of a minimally invasive (MI) surgical approach using a human MI lumbar retractor for canine lumbosacral dorsal laminectomy and partial discectomy and to compare this technique to the standard open surgical (OS) approach. METHODS Lumbosacral dorsal laminectomy and partial discectomy was performed on 16 large-breed canine cadavers using either a standard OS (n=8) or MI (n=8) approach. Skin and fascial incision length, procedure time, and intraoperative complications were recorded. Postoperatively specimens were evaluated for laminectomy and discectomy dimensions, and visible damage to the cauda equina and exiting nerve roots. RESULTS Median length of skin and fascial incisions in the OS group were longer than in the MI group (p<0.001). Median laminectomy length was similar between both approaches (p=0.234) but width was greater for the MI than OS approach (p=0.002). Both approaches achieved similar partial discectomy width (p=0.279). Overall surgical time was longer for MI approaches compared to OS, with a median of 18.5 (min 15.5, max 21.8) minutes for MI compared to 14.6 (min 13.1, max 16.9) minutes for OS (p=0.001). CONCLUSIONS The MI approach reduced incision lengths while retaining comparable laminectomy and discectomy dimensions. For this in vitro model the MI approach required more time to complete, but this difference may not be relevant in clinical cases. CLINICAL RELEVANCE Dogs undergoing lumbosacral dorsal laminectomy are commonly large-breed dogs. The traditional open approach requires a large skin incision and soft tissue dissection, especially in overweight animals. A MI approach accomplishing the same surgical result while minimising soft tissue trauma could reduce post-operative pain and recovery time, and may lower wound-related complications. Clinical studies are needed to confirm postoperative benefit and assess operating times in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Nail unit melanoma (NUM) is a variant of acral lentiginous melanoma. The differential diagnosis is wide but an acquired brown streak in the nail of a fair-skinned adult person must be considered a potential melanoma. Dermoscopy helps clinicians to more accurately decide if a nail apparatus biopsy is necessary. OBJECTIVE Detailed evaluation of clinical and dermoscopy features and description of conservative surgery of in situ NUM. METHODS Retrospective study of in situ NUM diagnosed and treated with conservative surgical management in the authors' center from 2008 to 2013. RESULTS Six cases of NUM were identified: 2 male and 4 female patients, age range at diagnosis of 44 to 76 years. All patients underwent complete nail unit removal with at least 6-mm security margins around the anatomic boundaries of the nail. The follow-up varies from 4 to 62 months. CONCLUSION Nail unit melanomas pose a difficult diagnostic and therapeutic challenge. Wide excision is sufficient, whereas phalanx amputation is unnecessary and associated with significant morbidity for patients with in situ or early invasive melanoma. Full-thickness skin grafting or second-intention healing after total nail unit excision is a simple procedure providing a good functional and cosmetic outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare intraoperative cerebral microembolic load between minimally invasive extracorporeal circulation (MiECC) and conventional extracorporeal circulation (CECC) during isolated surgical aortic valve replacement (SAVR), we conducted a randomized trial in patients undergoing primary elective SAVR at a tertiary referral hospital. The primary outcome was the procedural phase-related rate of high-intensity transient signals (HITS) on transcranial Doppler ultrasound. HITS rate was used as a surrogate of cerebral microembolism in pre-defined procedural phases in SAVR using MiECC or CECC with (+F) or without (-F) an oxygenator with integrated arterial filter. Forty-eight patients were randomized in a 1:1 ratio to MiECC or CECC. Due to intraprocedural Doppler signal loss (n = 3), 45 patients were included in final analysis. MiECC perfusion regimen showed a significantly increased HITS rate compared to CECC (by a factor of 1.75; 95% confidence interval, 1.19-2.56). This was due to different HITS rates in procedural phases from aortic cross-clamping until declamping [phase 4] (P = 0.01), and from aortic declamping until stop of extracorporeal perfusion [phase 5] (P = 0.05). Post hoc analysis revealed that MiECC-F generated a higher HITS rate than CECC+F (P = 0.005), CECC-F (P = 0.05) in phase 4, and CECC-F (P = 0.03) in phase 5, respectively. In open-heart surgery, MiECC is not superior to CECC with regard to gaseous cerebral microembolism. When using MiECC for SAVR, the use of oxygenators with integrated arterial line filter appears highly advisable. Only with this precaution, MiECC confers a cerebral microembolic load comparable to CECC during this type of open heart surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-contrast post-mortem computed tomography (pm-CT) is useful in the evaluation of bony pathologies, whereas minimally invasive pm-CT-angiography allows for the detection of subtle vascular lesions. We present a case of an accidentally self-inflicted fatal bullet wound to the chest where pm-CT-angiography revealed a small laceration of the anterior interventricular branch of the left coronary artery and a tiny disruption of the right ventricle with pericardial and pleural effusion. Subsequent autopsy confirmed our radiological findings. Post-mortem CT-angiography has a great potential for the detection of vascular lesions and can be considered equivalent to autopsy for selected cases in forensic medicine.