46 resultados para Low-index surfaces


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a voltammetric and in situ STM study of 11-ferrocenyl-1-undecanethiol (FcC11) assembled on low-index single crystal and polycrystalline gold electrodes. The influence of electrode surface structure as well as of structure defects in the self-assembled FcC11 monolayers on the electrochemical response during the oxidation and reduction of the terminal ferrocene group is explored. The nature of the redox peaks is discussed in detail. We identified the coexistence of disordered FcC11 regions with 2D patches of “locally ordered” FcC11 species. We demonstrate that close-packed domains are preferentially formed at atomically flat terraces. Increasing the defect density of the substrate surface leads to a decreasing amount of locally ordered FcC11 molecules.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have studied Au(55 nm)@SiO2 nanoparticles (NPs) on two low-index phases of gold and platinum single crystal electrodes in ClO4– and SO42– ion-containing electrolytes by both electrochemical methods and in-situ shell-isolated nanoparticle enhanced Raman spectroscopy (SHINERS). We showed the blocking of the electrode with surfactants originating from the synthesis of as-prepared SHINERS NPs. We introduce an efficient procedure to overcome this problem, which provides a fundamental platform for the application of SHINERS in surface electrochemistry and beyond. Our method is based on a hydrogen evolution treatment of the SHINERS-NP-modified single-crystal surfaces. The reliability of our preparation strategy is demonstrated in electrochemical SHINERS experiments on the potential-controlled adsorption and phase formation of pyridine on Au(hkl) and Pt(hkl). We obtained high-quality Raman spectra on these well-defined and structurally carefully characterized single-crystal surfaces. The analysis of the characteristic A1 vibrational modes revealed perfect agreement with the interpretation of single-crystal voltammetric and chronoamperometric experiments. Our study demonstrates that the SHINERS protocol developed in this work qualifies this Raman method as a pioneering approach with unique opportunities for in situ structure and reactivity studies at well-defined electrochemical solid/liquid interfaces.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The risk to have a stroke during childhood is at least as frequent as to suffer from a brain tumour. Unlike adults, in whom ischaemic strokes overweigh haemorrhagic strokes, ischaemic and haemorrhagic strokes are equally frequent in children, occurring with an incidence of 2 - 3/100'000 children/year. Even though the clinical presentation of arterial-ischaemic stroke in children (pedAIS) is similar to adults, time to diagnosis is longer. The delay to diagnosis is mainly explained by the low index of suspicion of both the general population and the medical personnel, a broad range of differential diagnoses, and the fact that diagnostic imaging in children often requires sedation, which is not always readily available. PedAIS is a multiple risk problem, usually occurring due to a combination of risk factors, such as infectious diseases, dehydration, trauma or an underlying condition such as congenital heart disease. Still little is known about the appropriate management of pedAIS. Supportive measures are considered to be the mainstay of therapy. The use of antithrombotic medication depends on pedAIS aetiology. In an ongoing multicenter trial, the safety and effectiveness of thrombolysis are currently being investigated. PedAIS carries an important mortality and morbidity, with neurological and neuropsychological deficits persisting in two thirds of the affected children.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The presence of liquid water is a requirement of habitability on a planet. Possible indicators of liquid surface water on Mars include intermittent flow-like features observed on sloping terrains. These recurring slope lineae are narrow, dark markings on steep slopes that appear and incrementally lengthen during warm seasons on low-albedo surfaces. The lineae fade in cooler seasons and recur over multiple Mars years. Recurring slope lineae were initially reported to appear and lengthen at mid-latitudes in the late southern spring and summer and are more common on equator-facing slopes where and when the peak surface temperatures are higher. Here we report extensive activity of recurring slope lineae in equatorial regions of Mars, particularly in the deep canyons of Valles Marineris, from analysis of data acquired by the Mars Reconnaissance Orbiter. We observe the lineae to be most active in seasons when the slopes often face the sun. Expected peak temperatures suggest that activity may not depend solely on temperature. Although the origin of the recurring slope lineae remains an open question, our observations are consistent with intermittent flow of briny water. Such an origin suggests surprisingly abundant liquid water in some near-surface equatorial regions of Mars.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the test characteristics of the shock index (SI) and the simplified pulmonary embolism severity index (sPESI) for predicting 30-day outcomes in a cohort of 1,206 patients with objectively confirmed pulmonary embolism (PE). The primary outcome of the study was all-cause mortality. The secondary outcome was nonfatal symptomatic recurrent venous thromboembolism (VTE) or nonfatal major bleeding. Overall, 119 (9.9%) out of 1,206 patients died (95% CI 8.2-11.5%) during the first month of follow-up. The sPESI classified fewer patients as low-risk (369 (31%) out of 1,206 patients, 95% CI 28-33%) compared to the SI (1,024 (85%) out of 1,206 patients, 95% CI 83-87%) (p<0.001). Low-risk patients based on the sPESI had a lower 30-day mortality than those based on the SI (1.6% (95% CI 0.3-2.9%) versus 8.3% (95% CI 6.6-10.0%)), while the 30-day rate of nonfatal recurrent VTE or major bleeding was similar (2.2% (95%CI 0.7-3.6%) versus 3.3% (95%CI 2.2-4.4%)). The net reclassification improvement with the sPESI was 13.4% (p = 0.07). The integrated discrimination improvement was estimated as 1.8% (p<0.001). The sPESI quantified the prognosis of patients with PE better than the SI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two polycrystalline diamond surfaces, manufactured by chemical vapour deposition (CVD) technique, are investigated regarding their applicability as charge state conversion surfaces (CS) for use in a low energy neutral atom imaging instrument in space research. The capability of the surfaces for converting neutral atoms into negative ions via surface ionisation processes was measured for hydrogen and oxygen with particle energies in the range from 100 eV to 1 keV and for angles of incidence between 6 deg and 15 deg. We observed surface charging during the surface ionisation processes for one of the CVD samples due to low electrical conductivity of the material. Measurements on the other CVD diamond sample resulted in ionisation efficiencies of ~2 % for H and up to 12 % for O. Analysis of the angular scattering revealed very narrow and almost circular scattering distributions. Comparison of the results with the data of the CS of the IBEX-Lo sensor shows that CVD diamond has great potential as CS material for future space missions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To develop a minimally destructive technique for removing the smear layer produced by cutting and polishing specimens of dentine prepared for use in experimental studies, e.g. on occlusion of dentinal tubules by oral health products. The aim was to avoid the damage caused by conventional techniques utilising short exposures to solutions with very low pH. METHODS: Two acetate buffers, pH 5.5, containing different concentrations of calcium and phosphate, with -log(ion activity product with respect to hydroxyapatite) (pI(HA)) of 55 or 56, were tested on slices of dentine using scanning electron microscopy (SEM). RESULTS: A solution which, from previous work, was slightly undersaturated with respect to dentine mineral, with a pI(HA) of 56, was found to remove smear layers produced by cutting and/or polishing after 15 min. However, to reliably remove debris occluding the tubules an exposure time of 2h, followed by brief ultrasonication, was necessary. After 2h treatment with this buffer, only a small amount of demineralization of the surface was detectable by SEM, while calcium and phosphorus were detectable by X-ray dispersive spectroscopy. CONCLUSION: It is possible to remove smear layers, and to open dentinal tubules, by a reasonably short exposure to an acidic buffer which is undersaturated with respect to dentine mineral.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa ( ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment ( : 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk ( : 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: As a previous study revealed, arts speech therapy (AST) affects cardiorespiratory interaction [1]. The aim of the present study was to investigate whether AST also has effects on brain oxygenation and hemodynamics measured non-invasively using near-infrared spectroscopy (NIRS). Material and methods: NIRS measurements were performed on 17 subjects (8 men and 9 women, mean age: 35.6 ± 12.7 y) during AST. Each measurement lasted 35 min, comprising 8 min pre-baseline, 10 min recitation and 20 min post-baseline. For each subject, measurements were performed for three different AST recitation tasks (recitation of alliterative, hexameter and prose verse). Relative concentration changes of oxyhemoglobin (Δ[O2Hb]) and deoxyhemoglobin (Δ[HHb]) as well as the tissue oxygenation index (TOI) were measured using a Hamamatsu NIRO300 NIRS device and a sensor placed on the subjects forehead. Movement artifacts were removed using a novel method [2]. Statistical analysis (Wilcoxon test) was applied to the data to investigate (i) if the recitation causes changes in the median values and/or in the Mayer wave power spectral density (MW-PSD, range: 0.07–0.13 Hz) of Δ[O2Hb], Δ[HHb] or TOI, and (ii) if these changes vary between the 3 recitation forms. Results: For all three recitation styles a significant (p < 0.05) decrease in Δ[O2Hb] and TOI was found, indicating a decrease in blood flow. These decreases did not vary significantly between the three styles. MW-PSD increased significantly for Δ[O2Hb] when reciting the hexameter and prose verse, and for Δ[HHb] and TOI when reciting alliterations and hexameter, representing an increase in Mayer waves. The MW-PSD increase for Δ[O2Hb] was significantly larger for the hexameter verse compared to alliterative and prose verse Conclusion: The study showed that AST affects brain hemodynamics (oxygenation, blood flow and Mayer waves). Recitation caused a significant decrease in cerebral blood flow for all recitation styles as well as an increase in Mayer waves, particularly for the hexameter, which may indicate a sympathetic activation. References 1. D. Cysarz, D. von Bonin, H. Lackner, P. Heusser, M. Moser, H. Bettermann. Am J Physiol Heart Circ Physiol, 287 (2) (2004), pp. H579–H587 2. F. Scholkmann, S. Spichtig, T. Muehlemann, M. Wolf. Physiol Meas, 31 (5) (2010), pp. 649–662

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low simplified Pulmonary Embolism Severity Index (sPESI), defined as age ≤80 years and absence of systemic hypotension, tachycardia, hypoxia, cancer, heart failure, and lung disease, identifies low-risk patients with acute pulmonary embolism (PE). It is unknown whether cardiac troponin testing improves the prediction of clinical outcomes if the sPESI is not low. In the prospective Swiss Venous Thromboembolism Registry, 369 patients with acute PE and a troponin test (conventional troponin T or I, highly sensitive troponin T) were enrolled from 18 hospitals. A positive test result was defined as a troponin level above the manufacturers assay threshold. Among the 106 (29%) patients with low sPESI, the rate of mortality or PE recurrence at 30 days was 1.0%. Among the 263 (71%) patients with high sPESI, 177 (67%) were troponin-negative and 86 (33%) troponin-positive; the rate of mortality or PE recurrence at 30 days was 4.6% vs. 12.8% (p=0.015), respectively. Overall, risk assessment with a troponin test (hazard ratio [HR] 3.39, 95% confidence interval [CI] 1.38-8.37; p=0.008) maintained its prognostic value for mortality or PE recurrence when adjusted for sPESI (HR 5.80, 95%CI 0.76-44.10; p=0.09). The combination of sPESI with a troponin test resulted in a greater area under the receiver-operating characteristic curve (HR 0.72, 95% CI 0.63-0.81) than sPESI alone (HR 0.63, 95% CI 0.57-0.68) (p=0.023). In conclusion, although cardiac troponin testing may not be required in patients with a low sPESI, it adds prognostic value for early death and recurrence for patients with a high sPESI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Most people experience low back pain (LBP) at least once in their lifetime. Only a minority of them go on to develop persistent LBP. However, the socioeconomic costs of persistent LBP significantly exceed the costs of the initial acute LBP episode. AIMS: To identify factors that influence the progression of acute LBP to the persistent state at an early stage. METHODS: Prospective inception cohort study of patients attending a health practitioner for their first episode of acute LBP or recurrent LBP after a pain free period of at least 6 months. Patients were assessed at baseline addressing occupational and psychological factors as well as pain, disability, quality of life and physical activity and followed up at 3, 6, 12 weeks and 6 months. Variables were combined to the three indices 'working condition', 'depression and maladaptive cognitions' and 'pain and quality of life'. RESULTS: The index 'depression and maladaptive cognitions' was found to be a significant baseline predictor for persistent LBP up to 6 months (OR 5.1; 95% CI: 1.04-25.1). Overall predictive accuracy of the model was 81%. CONCLUSIONS: In this study of patients with acute LBP in a primary care setting psychological factors at baseline correlated with a progression to persistent LBP up to 6 months. The benefit of including factors such as 'depression and maladaptive cognition' in screening tools is that these factors can be addressed in primary and secondary prevention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Most people experience low back pain (LBP) at least once in their lifetime. Only a minority of them go on to develop persistent LBP. However, the socioeconomic costs of persistent LBP significantly exceed the costs of the initial acute LBP episode. AIMS: To identify factors that influence the progression of acute LBP to the persistent state at an early stage. METHODS: Prospective inception cohort study of patients attending a health practitioner for their first episode of acute LBP or recurrent LBP after a pain free period of at least 6 months. Patients were assessed at baseline addressing occupational and psychological factors as well as pain, disability, quality of life and physical activity and followed up at 3, 6, 12 weeks and 6 months. Variables were combined to the three indices 'working condition', 'depression and maladaptive cognitions' and 'pain and quality of life'. RESULTS: The index 'depression and maladaptive cognitions' was found to be a significant baseline predictor for persistent LBP up to 6 months (OR 5.1; 95% CI: 1.04-25.1). Overall predictive accuracy of the model was 81%. CONCLUSIONS: In this study of patients with acute LBP in a primary care setting psychological factors at baseline correlated with a progression to persistent LBP up to 6 months. The benefit of including factors such as 'depression and maladaptive cognition' in screening tools is that these factors can be addressed in primary and secondary prevention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with pulmonary embolism (PE). Recently, a simplified version of the PESI was developed. We sought to compare the prognostic performance of the original and simplified PESI. Using data from 15,531 patients with PE, we compared the proportions of patients classified as low versus higher risk between the original and simplified PESI and estimated 30-day mortality within each risk group. To assess the models' accuracy to predict mortality, we calculated sensitivity, specificity, and predictive values and likelihood ratios for low- versus higher-risk patients. We also compared the models' discriminative power by calculating the area under the receiver-operating characteristic curve. The overall 30-day mortality was 9.3%. The original PESI classified a significantly greater proportion of patients as low-risk than the simplified PESI (40.9% vs. 36.8%; p<0.001). Low-risk patients based on the original and simplified PESI had a mortality of 2.3% and 2.7%, respectively. The original and simplified PESI had similar sensitivities (90% vs. 89%), negative predictive values (98% vs. 97%), and negative likelihood ratios (0.23 vs. 0.28) for predicting mortality. The original PESI had a significantly greater discriminatory power than the simplified PESI (area under the ROC curve 0.78 [95% CI: 0.77-0.79] vs. 0.72 [95% CI: 0.71-0.74]; p<0.001). In conclusion, even though the simplified PESI accurately identified patients at low-risk of adverse outcomes, the original PESI classified a higher proportion of patients as low-risk and had a greater discriminatory power than the simplified PESI.