53 resultados para Invisible brackets


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the study was to evaluate the biological effects of water eluents from polycarbonate based esthetic orthodontic brackets. METHODS: The composite polycarbonate brackets tested were Silkon Plus (SL, fiber-glass-reinforced), Elan ME (EL, ceramic particle-reinforced) and Elegance (EG, fiber-glass-reinforced). An unfilled polyoxymethylene bracket (Brilliant, BR) was used as control. The brackets' composition was analyzed by ATR-FTIR spectrometry. The cytotoxicity and estrogenicity of the eluents obtained after 3months storage of the brackets in water (37°C) were investigated in murine fibroblasts (NIH 3T3), breast (MCF-7) and cervical cancer (CCl-2/Hela) cell lines. RESULTS: SL and EG were based on aromatic-polycarbonate matrix, whereas EL consisted of an aromatic polycarbonate-polyethylene terepthalate copolymer. A significant induction of cell death and a concurrent decrease in cell proliferation was noted in the EG eluent-treated cells. Moreover, EG eluent significantly reduced the levels of the estrogen signaling associated gene pS2, specifically in MCF7 cells, suggesting that cell death induced by this material is associated with downregulation of estrogen signaling pathways. Even though oxidative stress mechanisms were equally activated by all eluents, the EG eluents induced expression of apoptosis inducing factor (AIF) and reduced Bcl-xL protein levels. SIGNIFICANCE: Some polycarbonate-based composite brackets when exposed to water release substances than activate mitochondrial apoptosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The objective of this systematic review was to assess the short- and long-term release of components of orthodontic adhesives and polycarbonate brackets in the oral environment. METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS No randomized controlled trial was identified. In the absence of randomized controlled trials, observational studies were included. Eleven studies met the inclusion criteria. All were observational studies conducted in vivo or in vitro. The bisphenol-A release from orthodontic bonding resins was found to be between 0.85 and 20.88 ng per milliliter in vivo, and from traces to 65.67 ppm in vitro. Polycarbonate brackets released amounts of 22.24 μg per gram in ethanol solution and 697 μg per gram after 40 months in water. Bis-GMA and TEGDMA leaching in vitro reached levels of 64 and 174 mg per 10 μL, respectively. Because of the heterogeneity in methodologies and reporting, only qualitative synthesis was performed. CONCLUSIONS The available evidence on this topic derived from observational in-vivo and in-vitro studies that represent a moderate level of evidence. The variety of setups and the different units allied to the diversity of reporting among studies did not allow calculation of pooled estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. RESULTS Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. CONCLUSIONS/IMPLICATIONS Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. MATERIALS AND METHODS The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. RESULTS The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. CONCLUSION The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dual-effects model of social control proposes that social control leads to increased psychological distress but also to better health practices. However, findings are inconsistent, and recent research suggests that the most effective control is unnoticed by the receiver (i. e., invisible). Yet, investigations of the influence of invisible control on daily negative affect and smoking have been limited. Using daily diaries, we investigated how invisible social control was associated with negative affect and smoking. Overall, 100 smokers (72.0 % men, age M = 40.48, SD = 9.82) and their nonsmoking partners completed electronic diaries from a self-set quit date for 22 consecutive days, reporting received and provided social control, negative affect, and daily smoking. We found in multilevel analyses of the within-person process that on days with higher-than-average invisible control, smokers reported more negative affect and fewer cigarettes smoked. Findings are in line with the assumptions of the dual-effects model of social control: Invisible social control increased daily negative affect and simultaneously reduced smoking at the within-person level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dual-effects model of social control not only assumes that social control leads to better health practices but also arouses psychological distress. However, findings are inconsistent. The present study advances the current literature by examining social control from a dyadic perspective in the context of smoking. In addition, the study examines whether control, continuous smoking abstinence, and affect are differentially related for men and women. Before and three weeks after a self-set quit attempt, we examined 106 smokers (77 men, mean age: 40.67, average number of cigarettes smoked per day: 16.59 [SD=8.52, range=1-40] at baseline and 5.27 [SD=6.97, range=0-40] at follow-up) and their nonsmoking heterosexual partners, assessing received and provided control, continuous abstinence, and affect. With regard to smoker's affective reactions, partner's provided control was related to an increase in positive and to a decrease in negative affect, but only for female smokers. Moreover, the greater the discrepancy between smoker received and partner's provided control was the more positive affect increased and the more negative affect decreased, but again only for female smokers. These findings demonstrate that female smokers' well-being was raised over time if they were not aware of the control attempts of their nonsmoking partners, indicating positive effects of invisible social control. This study's results emphasize the importance of applying a dyadic perspective and taking gender differences in the dual-effects model of social control into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Social support receipt from one's partner is assumed to be beneficial for successful smoking cessation. However, support receipt can have costs. Recent research suggests that the most effective support is unnoticed by the receiver (i.e., invisible). Therefore, this study examined the association between everyday levels of dyadic invisible emotional and instrumental support, daily negative affect, and daily smoking after a self-set quit attempt in smoker–non-smoker couples. Methods Overall, 100 smokers (72.0% men, mean age M = 40.48, SD = 9.82) and their non-smoking partners completed electronic diaries from a self-set quit date on for 22 consecutive days, reporting daily invisible emotional and instrumental social support, daily negative affect, and daily smoking. Results Same-day multilevel analyses showed that at the between-person level, higher individual mean levels of invisible emotional and instrumental support were associated with less daily negative affect. In contrast to our assumption, more receipt of invisible emotional and instrumental support was related to more daily cigarettes smoked. Conclusions The findings are in line with previous results, indicating invisible support to have beneficial relations with affect. However, results emphasize the need for further prospective daily diary approaches for understanding the dynamics of invisible support on smoking cessation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The dual-effects model of social control proposes that social control leads to better health practices, but also arouses psychological distress. However, findings are inconsistent in relation to health behavior and psychological distress. Recent research suggests that the most effective control is unnoticed by the receiver (i.e., invisible). There is some evidence that invisible social control is beneficial for positive and negative affective reactions. Yet, investigations of the influence of invisible social control on daily smoking and distress have been limited. In daily diaries, we investigated how invisible social control is associated with number of cigarettes smoked and negative affect on a daily basis. Methods: Overall, 99 smokers (72.0% men, mean age M = 40.48, SD = 9.82) and their non-smoking partners completed electronic diaries from a self-set quit date for 22 consecutive days within the hour before going to bed, reporting received and provided social control, daily number of cigarettes smoked, and negative affect. Results: Multilevel analyses indicated that between-person levels of invisible social control were associated with lower negative affect, whereas they were unrelated to number of cigarettes smoked. On days with higher-than-average invisible social control, smokers reported less cigarettes smoked and more negative affect. Conclusions: Between-person level findings indicate that invisible social control can be beneficial for negative affect. However, findings on the within-person level are in line with the assumptions of the dual-effects model of social control: Invisible social control reduced daily smoking and simultaneously increased daily negative affect within person.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for evidence of invisible-particle decay modes of a Higgs boson produced in association with a Z boson at the Large Hadron Collider is presented. No deviation from the standard model expectation is observed in 4.5 fb−1 (20.3 fb−1) of 7 (8) TeV pp collision data collected by the ATLAS experiment. Assuming the standard model rate for ZH production, an upper limit of 75%, at the 95% confidence level is set on the branching ratio to invisible-particle decay modes of the Higgs boson at a mass of 125.5 GeV. The limit on the branching ratio is also interpreted in terms of an upper limit on the allowed dark matter-nucleon scattering cross section within a Higgs-portal dark matter scenario. Within the constraints of such a scenario, the results presented in this Letter provide the strongest available limits for low-mass dark matter candidates. Limits are also set on an additional neutral Higgs boson, in the mass range 110 < mH < 400 GeV, produced in association with a Z boson and decaying to invisible particles.