164 resultados para Intracardiac Echocardiography


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: We sought to assess the safety and clinical efficacy of patent foramen ovale (PFO) closure under fluoroscopic guidance only, without intraprocedural echocardiography. BACKGROUND: Percutaneous PFO closure has been shown to be safe and feasible using several devices. It is generally performed using simultaneously fluoroscopic and transesophageal or intracardiac echocardiographic guidance. Transesophageal echocardiography requires sedation or general anesthesia and intubation to avoid aspiration. Intracardiac echocardiography is costly and has inherent risks. Both lengthen the procedure. The Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, Minnesota) can be safely implanted without echocardiographic guidance. METHODS: A total of 620 patients (51 +/- 12 years; 66% male) underwent PFO closure using the Amplatzer PFO Occluder for secondary prevention of presumed paradoxical embolism. Based on size and mobility of the PFO and the interatrial septum, an 18-mm device was used in 50 patients, a 25-mm device in 492, and a 35-mm device in 78. RESULTS: All procedures were successful, with 5 procedural complications (0.8%): 4 arteriovenous fistulae requiring elective surgical correction, and 1 transient ischemic attack. Contrast transesophageal echocardiography at 6 months showed complete closure in 91% of patients, whereas a minimal, moderate, or large residual shunt persisted in 6%, 2%, and 1%, respectively. During a mean follow-up period of 3.0 +/- 1.9 years (median: 2.6 years; total patient-years: 1,871), 5 ischemic strokes, 8 transient ischemic attacks, and no peripheral emboli were reported. Freedom from recurrent ischemic stroke, transient ischemic attack, or peripheral embolism was 99% at 1 year, 99% at 2 years, and 97% at 5 years. CONCLUSIONS: The Amplatzer PFO Occluder affords excellent safety and long-term clinical efficacy of percutaneous PFO closure without intraprocedural echocardiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES We sought to assess the safety and efficacy of percutaneous closure of atrial septal defects (ASDs) under fluoroscopic guidance only, without periprocedural echocardiographic guidance. BACKGROUND Percutaneous closure of ASDs is usually performed using simultaneous fluoroscopic and transthoracic, transesophageal (TEE), or intracardiac echocardiographic (ICE) guidance. However, TEE requires deep sedation or general anesthesia, which considerably lengthens the procedure. TEE and ICE increase costs. METHODS Between 1997 and 2008, a total of 217 consecutive patients (age, 38 ± 22 years; 155 females and 62 males), of whom 44 were children ≤16 years, underwent percutaneous ASD closure with an Amplatzer ASD occluder (AASDO). TEE guidance and general anesthesia were restricted to the children, while devices were implanted under fluoroscopic guidance only in the adults. For comparison of technical safety and feasibility of the procedure without echocardiographic guidance, the children served as a control group. RESULTS The implantation procedure was successful in all but 3 patients (1 child and 2 adults; 1.4%). Mean device size was 23 ± 8 mm (range, 4-40 mm). There was 1 postprocedural complication (0.5%; transient perimyocarditis in an adult patient). At last echocardiographic follow-up, 13 ± 23 months after the procedure, 90% of patients had no residual shunt, whereas a minimal, moderate, or large shunt persisted in 7%, 1%, and 2%, respectively. Four adult patients (2%) underwent implantation of a second device for a residual shunt. During a mean follow-up period of 3 ± 2 years, 2 deaths and 1 ischemic stroke occurred. CONCLUSION According to these results, percutaneous ASD closure using the AASDO without periprocedural echocardiographic guidance seems safe and feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present the case of an 81-year-old patient with severe aortic stenosis who experienced left ventricular embolization of an aortic bioprosthesis during transapical aortic valve implantation. The authors discuss reasons for prosthesis embolization and reinforce the attention to technical details and the widespread use of multimodality imaging techniques. In this context, transesophageal echocardiography appears indispensable in the detection and management of procedure-related complications.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rhythm analysis of the fetal heart is hampered by the inability to routinely obtain electrocardiographic recordings of the fetus. Doppler studies of fetal cardiac tissue movements, assessing cardiac movements both qualitatively and quantitatively, have recently been described. We used a conventional high-resolution ultrasound system to obtain rhythm data from pulsed-wave tissue Doppler signals of the fetal heart in normal cardiac rhythm and in a variety of fetal cardiac arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac biomarkers and echocardiography for assessing right ventricular function are recommended to risk stratify patients with acute non-massive pulmonary embolism (PE), but it remains unclear if these tests are performed systematically in daily practice. Design and methods: Overall, 587 patients with acute non-massive PE from 18 hospitals were enrolled in the Swiss Venous Thromboembolism Registry (SWIVTER): 178 (30%) neither had a biomarker test nor an echocardiographic evaluation, 196 (34%) had a biomarker test only, 47 (8%) had an echocardiogram only and 166 (28%) had both tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recently, several cases of symptomatic and/or electrically detectable intracardiac inside-out abrasions in silicon-coated Riata® and Riata® ST leads have been described. However, the prevalence in asymptomatic patients with unremarkable implantable cardioverter defibrillator (ICD) interrogation is unknown. The aim of this study was to determine the prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads. METHODS: All 52 patients with an active silicone-coated Riata® and Riata® ST lead followed up in our outpatient clinic were scheduled for a premature ICD interrogation and a biplane chest radiograph. When an intracardiac inside-out abrasion was suspected, this finding was confirmed by fluoroscopy. RESULTS: Mean time since implantation was 71±18months. An intracardiac inside-out abrasion was confirmed by fluoroscopy in 6 patients (11.5%). Mean time from lead implantation to detection of intracardiac inside-out abrasion was 79±14months. In all patients with an intracardiac inside-out abrasion, ICD interrogation showed normal and stable electrical parameters. Retrospectively, in 4 of these 6 patients, a coronary angiography performed 25±18months before diagnosis of intracardiac inside-out abrasion already showed the defect. Despite undetected intracardiac inside-out abrasion, 2 of these 4 patients experienced adequate antitachycardia pacing and ICD-shocks. ICD leads were replaced in all 6 patients. CONCLUSIONS: The prevalence of asymptomatic intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads is higher than 10% when assessed by fluoroscopy, and most intracardiac inside-out abrasions are not detectable by ICD interrogation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroke is a significant cause of serious disability and death worldwide. A substantial proportion of strokes are related to an underlying cardiac embolic source, most commonly in association with atrial arrhythmias (fibrillation/flutter). Atrial fibrillation is considered a major risk factor for stroke. Although long-term prophylactic oral anticoagulation has been shown to be very effective in reducing stroke in patients with atrial fibrillation, it has a number of major limitations and is not feasible in all patients. In such cases, the use of percutaneously (transvenous) implanted left atrial appendage occlusive devices or surgical appendage obliteration is being explored. Similarly, the presence of a patent foramen ovale, especially in the presence of an atrial septal aneurysm, is now recognized as an important potential mediator of paradoxical cardiogenic embolism. Percutaneous patent foramen ovale closure is becoming increasingly established as a safe and effective means of preventing recurrent strokes in the presence of a patent foramen ovale. In this account, the authors discuss the intracardiac devices and techniques available and the relative merits of their use for stroke prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.