183 resultados para Heart Valve Prosthesis Implantation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the safety, device performance, and clinical outcome up to 2 years for patients undergoing transcatheter aortic valve implantation (TAVI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 3f Enable aortic bioprosthesis (ATS Medical, Inc, Minneapolis, Minn) represents a new generation of equine pericardial self-expanding valve designed for sutureless implantation. This study evaluated technical aspects of implantation and safety and effectiveness of the valve in the short term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry (PIV). Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising due to an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesise that a comprehensive cardiac rehabilitation programme can improve physical capacity and self-assessed mental health and reduce hospitalisation and healthcare costs after heart valve surgery. Methods A randomised clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients, 1:1 intervention to control group, using central randomisation, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise, and a psycho-educational intervention comprising five consultations. Primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. Secondary outcome is self-assessed mental health measured by the standardised questionnaire Short Form 36. Also, long-term healthcare utilisation and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design is used to evaluate qualitative and quantitative findings encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. Discussion The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). The pivoting region of MHVs is hemodynamically of special interest as it may be a region of high shear stresses, combined with areas of flow stagnation. Here, platelets can be activated and may form a thrombus which in the most severe case can compromise leaflet mobility. In this study we set up an experiment to replicate the pulsatile flow in the aortic root and to study the flow in the pivoting region under physiological hemodynamic conditions (CO = 4.5 L/min / CO = 3.0 L/min, f = 60 BPM). It was found that the flow velocity in the pivoting region could reach values close to that of the bulk flow during systole. At the onset of diastole the three valve leaflets closed in a very synchronous manner within an average closing time of 55 ms which is much slower than what has been measured for traditional bileaflet MHVs. Hot spots for elevated viscous shear stresses were found at the flanges of the housing and the tips of the leaflet ears. Systolic VSS was maximal during mid-systole and reached levels of up to 40 Pa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is rapidly evolving as an alternative treatment option for elderly patients with severe symptomatic aortic stenosis and excessive risk for surgical intervention. Transcatheter valve-in-valve implantation is an alternative approach to redo-surgery for patients with degeneration of a bioprosthetic valve. Herein are reported three cases of successful transcatheter aortic valve-in-valve implantation for severely regurgitant bioprosthetic valves with a clinical follow up of more than 12 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a patient with staphylococcus lugdunensis prosthetic aortic valve endocarditis and coronary septic embolism accompanied by antero-lateral myocardial infarction, embolic material was successfully aspirated from the bifurcation of the left anterior descending coronary artery and the first diagonal branch. A good angiographic result was documented six months thereafter when the patient presented with a second complication, pulsatile compression of the left main coronary artery by an abscess cavity originating between the aortic and mitral annulus, leading to congestive heart failure. The patient underwent successful surgical replacement of the aortic valve prosthesis with concomitant patch reconstruction of the annulus as well as tricuspid annuloplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.