72 resultados para Hearing (Physiology)
Resumo:
The cardiac voltage-gated Na(+) channel Na(v)1.5 generates the cardiac Na(+) current (INa). Mutations in SCN5A, the gene encoding Na(v)1.5, have been linked to many cardiac phenotypes, including the congenital and acquired long QT syndrome, Brugada syndrome, conduction slowing, sick sinus syndrome, atrial fibrillation, and dilated cardiomyopathy. The mutations in SCN5A define a sub-group of Na(v)1.5/SCN5A-related phenotypes among cardiac genetic channelopathies. Several research groups have proposed that Na(v)1.5 may be part of multi-protein complexes composed of Na(v)1.5-interacting proteins which regulate channel expression and function. The genes encoding these regulatory proteins have also been found to be mutated in patients with inherited forms of cardiac arrhythmias. The proteins that associate with Na(v)1.5 may be classified as (1) anchoring/adaptor proteins, (2) enzymes interacting with and modifying the channel, and (3) proteins modulating the biophysical properties of Na(v)1.5 upon binding. The aim of this article is to review these Na(v)1.5 partner proteins and to discuss how they may regulate the channel's biology and function. These recent investigations have revealed that the expression level, cellular localization, and activity of Na(v)1.5 are finely regulated by complex molecular and cellular mechanisms that we are only beginning to understand.
Resumo:
To present the auditory implant manipulator, a navigation-controlled mechanical and electronic system which enables minimally invasive ('keyhole') transmastoid access to the tympanic cavity.
Resumo:
A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.
Resumo:
To test, whether modern Internet telephony with a broadband transmission (0.1-8 kHz) of speech improves speech perception in comparison to conventional telephony (0.3-3.5 kHz) in hearing-impaired and normal-hearing adults.
Resumo:
Although non-organic hearing losses are relatively rare, it is important to identify suspicious findings early to be able to administer specific tests, such as objective measurements and specific counseling. In this retrospective study, we searched for findings that were specific ti or typical for non-organic hearing losses. Patient records from a 6 year period (2003-2008) from the University ENT Department of Bern, Switzerland, were reviewed. In this period, 40 subjects were diagnosed with a non-organic hearing loss (22 children, ages 7-16, mean 10.6 years; 18 adults, ages 19-57, mean 39.7 years; 25 females and 15 males). Pure tone audiograms in children and adults showed predominantly sensorineural and frequency-independent hearing losses, mostly in the range of 40-60 dB. In all cases, objective measurements (otoacoustic emissions and/or auditory-evoked potentials) indicated normal or substantially better hearing thresholds than those found in pure tone audiometry. In nine subjects (22.5%; 2 children, 7 adults), hearing aids had been fitted before the first presentation at our center. Six children (27%) had a history of middle ear problems with a transient hearing loss and 11 (50%) knew a person with a hearing loss. Two new and hitherto unreported findings emerged from the analysis: it was observed that a small air-bone gap of 5-20 dB was typical for non-organic hearing losses and that speech audiometry might show considerably poorer results than expected from pure tone audiometry.
Resumo:
The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.
Resumo:
Clinical and radiologic outcome analysis after petrous bone cholesteatoma (PBC) removal with simultaneous functional reconstruction.
Resumo:
High altitude constitutes an exciting natural laboratory for medical research. Although initially, the aim of high-altitude research was to understand the adaption of the organism to hypoxia and find treatments for altitude-related diseases, during the past decade or so, the scope of this research has broadened considerably. Two important observations led the foundation for the broadening of the scientific scope of high-altitude research. First, high-altitude pulmonary edema represents a unique model that allows studying fundamental mechanisms of pulmonary hypertension and lung edema in humans. Second, the ambient hypoxia associated with high-altitude exposure facilitates the detection of pulmonary and systemic vascular dysfunction at an early stage. Here, we will review studies that, by capitalizing on these observations, have led to the description of novel mechanisms underpinning lung edema and pulmonary hypertension and to the first direct demonstration of fetal programming of vascular dysfunction in humans.
Resumo:
To compare the patient benefit of the Bone-Anchored Hearing Aid (Baha) Divino and the Baha BP100 sound processors.
Resumo:
This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.
Resumo:
Reticulate pattern is one of the most important dermatological signs of a pathological process involving the superficial vascular networks. Vascular malformations, such as cutis marmorata congenita telangiectasia and benign forms of livedo reticularis, and sinister conditions, such as meningococcal meningitis or Sneddon's syndrome, can all present with a reticulate pattern. The clinical presentation and morphology is determined by the nature and extent of the underlying pathology and the involvement of a particular vascular network. This review has been divided into four instalments. In the present paper, we discuss the anatomy and physiology of the complex network of vascular structures that support the function of the skin and subcutis.