47 resultados para Ear, middle
Resumo:
Thiel-embalmed human whole head specimens represent an alternative model in middle ear research.
Resumo:
OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.
Resumo:
A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.
Resumo:
This paper presents a case of a 28-year-old male with a seizure episode and a 4-year history of intermittent tinnitus on the left ear. On computed tomography and magnetic resonance imaging, a density with rim enhancement was found at the temporal lobe, associated with mastoid tegmen destruction and middle ear mass, indicating cholesteatoma with complicating brain abscess. Evacuation of the brain abscess was performed with a combined otolaryngologic and neurosurgical procedures (canal wall-down mastoidectomy and temporal craniotomy). The pathology turned out to be infestation with Echinococcus granulosus.
Resumo:
Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model’s linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.
Resumo:
The goals of any treatment of cervical spine injuries are: return to maximum functional ability, minimum of residual pain, decrease of any neurological deficit, minimum of residual deformity and prevention of further disability. The advantages of surgical treatment are the ability to reach optimal reduction, immediate stability, direct decompression of the cord and the exiting roots, the need for only minimum external fixation, the possibility for early mobilisation and clearly decreased nursing problems. There are some reasons why those goals can be reached better by anterior surgery. Usually the bony compression of the cord and roots comes from the front therefore anterior decompression is usually the procedure of choice. Also, the anterior stabilisation with a plate is usually simpler than a posterior instrumentation. It needs to be stressed that closed reduction by traction can align the fractured spine and indirectly decompress the neural structures in about 70%. The necessary weight is 2.5 kg per level of injury. In the upper cervical spine, the odontoid fracture type 2 is an indication for anterior surgery by direct screw fixation. Joint C1/C2 dislocations or fractures or certain odontoid fractures can be treated with a fusion of the C1/C2 joint by anterior transarticular screw fixation. In the lower and middle cervical spine, anterior plating combined with iliac crest or fibular strut graft is the procedure of choice, however, a solid graft can also be replaced by filled solid or expandable vertebral cages. The complication of this surgery is low, when properly executed and anterior surgery may only be contra-indicated in case of a significant lesion or locked joints.
Resumo:
Recently, Petrella et al. described four patients with an unusual CD8+ lymphoid proliferation arising on the ear. These cases do not correspond clearly to any recognized category of cutaneous T-cell lymphoma (CTCL) described in the World Health Organization (WHO)/European Organization for Research and Treatment of Cancer (EORTC) 2005 classification.
Resumo:
Greenstick fractures suffered during growth have a high risk for refracture and posttraumatic deformity, particularly at the forearm diaphysis. The use of a preemptive completion of the fracture by manipulation of the concave cortex is controversial and data supporting this approach are few.
Resumo:
Concerns of rising healthcare costs and the ever increasing desire to improve surgical outcome have motivated the development of a new robotic assisted surgical procedure for the implantation of artificial hearing devices (AHDs). This paper describes our efforts to enable minimally invasive, cost effective surgery for the implantation of AHDs. We approach this problem with a fundamental goal to reduce errors from every component of the surgical workflow from imaging and trajectory planning to patient tracking and robot development. These efforts were successful in reducing overall system error to a previously unattained level.
Extraintestinal Crohn's disease mimicking autoimmune inner ear disease: a histopathological approach
Resumo:
Patients with autoimmune inner ear disease develop rapidly progressive sensorineural hearing loss over a period of several weeks or months, often accompanied by vestibular loss. This disease can occur as a distinct clinical entity or in association with an underlying autoimmune disorder. Treatment comprises immunosuppression by corticosteroids, cytostatic drugs or tumor necrosis factor- antagonists. We report histopathological and immunohistochemical findings of the inner ear of a patient with a granulomatous inner ear disease suffering from Crohn's disease that was nonresponsive to treatment and who underwent surgery for bilateral cochlear implants.
Resumo:
A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.
Resumo:
We present an update on clinical evaluation, staging, classification and treatment of canal cholesteatoma, including a meta-analysis of clinical data of the last 30 years.
Resumo:
Although non-organic hearing losses are relatively rare, it is important to identify suspicious findings early to be able to administer specific tests, such as objective measurements and specific counseling. In this retrospective study, we searched for findings that were specific ti or typical for non-organic hearing losses. Patient records from a 6 year period (2003-2008) from the University ENT Department of Bern, Switzerland, were reviewed. In this period, 40 subjects were diagnosed with a non-organic hearing loss (22 children, ages 7-16, mean 10.6 years; 18 adults, ages 19-57, mean 39.7 years; 25 females and 15 males). Pure tone audiograms in children and adults showed predominantly sensorineural and frequency-independent hearing losses, mostly in the range of 40-60 dB. In all cases, objective measurements (otoacoustic emissions and/or auditory-evoked potentials) indicated normal or substantially better hearing thresholds than those found in pure tone audiometry. In nine subjects (22.5%; 2 children, 7 adults), hearing aids had been fitted before the first presentation at our center. Six children (27%) had a history of middle ear problems with a transient hearing loss and 11 (50%) knew a person with a hearing loss. Two new and hitherto unreported findings emerged from the analysis: it was observed that a small air-bone gap of 5-20 dB was typical for non-organic hearing losses and that speech audiometry might show considerably poorer results than expected from pure tone audiometry.
Resumo:
To test whether in-the-canal (ITC) microphones have an impact on spatial discrimination and speech perception by taking advantage of auricular cues.