29 resultados para Conditional personal non-cure rate
Resumo:
INTRODUCTION: Urogenital prolapse is a very common condition in women with a prevalence of 30%. If conservative therapy fails or is not desired by the patient, prolapse repair is usually performed under general or regional anaesthetic. The aim of the study was to evaluate feasibility, efficacy and functional outcome after fascial prolapse repairs under local anaesthetic (LA). PATIENTS AND METHODS: Between November 1999 and December 2000, 130 consecutive patients presenting with anterior or posterior prolapse or both were invited to have their procedure performed under LA. All patients with a symptomatic minimum stage II prolapse were included. Prior to surgery all women completed a standardized questionnaire examining the specific and non-specific symptoms of prolapse and their situation was classified using the ICS Pelvic Organ Prolapse (POP-Q) system. Follow up was 30 months. Objective success was defined as a stage 1 or less and no symptoms of bulge, subjective success was defined as lack of specific or non-specific symptoms of prolapse. RESULTS: There were 128 patients who agreed to have their operations performed under LA: 68 in the anterior group, 52 in the posterior group and 8 with a combined anterior and posterior repair. Objective cure rate was 88% for posterior repair, 87% for anterior repair and 63% for combined repair. Success rates were no different in primary from recurrent cases. There were no intraoperative complications and operating time was 21 min (anterior repair) or 23 min (posterior repair). There was no de novo postoperative urinary or stool incontinence and all patients but two would have the operation performed again under the same circumstances. The two remaining refused due to embarrassment but for no other reason. CONCLUSION: Local anaesthetic prolapse repair is feasible and effective in middle term results. It is well accepted by the patients who benefit from less side effects and short hospital stay.
Resumo:
The primary objective was to determine the efficacy of a newly designed preoperative chemotherapy regimen in an attempt to improve the cure rate of children with high-risk hepatoblastoma.
Resumo:
Structure-activity relationship studies were carried out by chemical modification of manzamine A (1), 8-hydroxymanzamine A (2), manzamine F (14), and ircinal isolated from the sponge Acanthostrongylophora. The derived analogues were evaluated for antimalarial, antimicrobial, and antineuroinflammatory activities. Several modified products exhibited potent and improved in vitro antineuroinflammatory, antimicrobial, and antimalarial activity. 1 showed improved activity against malaria compared to chloroquine in both multi- and single-dose in vivo experiments. The significant antimalarial potential was revealed by a 100% cure rate of malaria in mice with one administration of 100 mg/kg of 1. The potent antineuroinflammatory activity of the manzamines will provide great benefit for the prevention and treatment of cerebral infections (e.g., Cryptococcus and Plasmodium). In addition, 1 was shown to permeate across the blood-brain barrier (BBB) in an in vitro model using a MDR-MDCK monolayer. Docking studies support that 2 binds to the ATP-noncompetitive pocket of glycogen synthesis kinase-3beta (GSK-3beta), which is a putative target of manzamines. On the basis of the results presented here, it will be possible to initiate rational drug design efforts around this natural product scaffold for the treatment of several different diseases.
Resumo:
Surgical repair of the rotator cuff repair is one of the most common procedures in orthopedic surgery. Despite it being the focus of much research, the physiological tendon-bone insertion is not recreated following repair and there is an anatomic non-healing rate of up to 94%. During the healing phase, several growth factors are upregulated that induce cellular proliferation and matrix deposition. Subsequently, this provisional matrix is replaced by the definitive matrix. Leukocyte- and platelet-rich fibrin (L-PRF) contain growth factors and has a stable dense fibrin matrix. Therefore, use of LPRF in rotator cuff repair is theoretically attractive. The aim of the present study was to determine 1) the optimal protocol to achieve the highest leukocyte content; 2) whether L-PRF releases growth factors in a sustained manner over 28 days; 3) whether standard/gelatinous or dry/compressed matrix preparation methods result in higher growth factor concentrations. 1) The standard L-PRF centrifugation protocol with 400 x g showed the highest concentration of platelets and leukocytes. 2) The L-PRF clots cultured in medium showed a continuous slow release with an increase in the absolute release of growth factors TGF-β1, VEGF and MPO in the first 7 days, and for IGF1, PDGF-AB and platelet activity (PF4=CXCL4) in the first 8 hours, followed by a decrease to close to zero at 28 days. Significantly higher levels of growth factor were expressed relative to the control values of normal blood at each culture time point. 3) Except for MPO and the TGFβ-1, there was always a tendency towards higher release of growth factors (i.e., CXCL4, IGF-1, PDGF-AB, and VEGF) in the standard/gelatinous- compared to the dry/compressed group. L-PRF in its optimal standard/gelatinous-type matrix can store and deliver locally specific healing growth factors for up to 28 days and may be a useful adjunct in rotator cuff repair.
Resumo:
Mastitis induced by Escherichia coli is often characterized by severe clinical signs, indicating a more powerful combat of the immune system against the pathogen compared with Staphylococcus aureus infections, which are often represented by chronic and subclinical diseases. The aim of this study was to test the major pathogenic component lipopolysaccharide (LPS) from E. coli and lipoteichoic acid (LTA) from Staph. aureus for their effects on blood-milk barrier integrity and the related transfer of immunoglobulins and lactate from blood into milk. A similar somatic cell count (SCC) increase was achieved by intramammary challenge of 1 quarter of 5 cows with 20 µg of LTA, and 8 cows with 0.2 µg of LPS (maximum log SCC/mL: 7). Milk IgG(1) concentrations increased in LPS- but not in LTA-challenged quarters. Milk IgG(2) concentrations were increased in treated quarters at 3h after LPS, and 6h after LTA challenge. Higher maximum levels of IgG(2) were reached in milk of LPS-treated quarters (173 ± 58 μg/mL) than of LTA-challenged quarters (62 ± 13 μg/mL). Immunoglobulin G(1) and IgG(2) levels did not change in control quarters. l-Lactate concentrations in milk increased 4h after LPS and 5h after LTA challenge and reached higher maximum levels in LPS- (221 ± 48 mg/L) than in LTA-treated quarters (77 ± 18 mg/L). In conclusion, a mammary inflammation on a quantitatively similar level based on SCC increase achieves a more efficient transfer of blood components such as IgG(2) via the blood-milk barrier if induced by LPS from E. coli than by LTA from Staph. aureus. This pathogen-specific difference may play an important role in the cure rate of the respective intramammary infection, which is usually lower in Staph. aureus- than in E. coli-induced mastitis.
Resumo:
OBJECTIVE: To investigate effects of intramammary administration of prednisolone on the immune response of mammary glands in cows. ANIMALS: 5 lactating Red Holsteins. PROCEDURES: Cows received a different intramammary infusion in each mammary gland (10 mg of prednisolone, 100 μg of lipopolysaccharide [LPS], 100 μg of LPS and 10 mg of prednisolone, or saline [0.9% NaCl] solution). Milk samples were collected before (time 0) and 3, 6, 9, 12, 24, and 36 hours after treatment. Somatic cell count (SCC), lactate dehydrogenase (LDH) activity, and concentrations of serum albumin (SA) and tumor necrosis factor (TNF)-α in milk and mRNA expression of TNF-α, interleukin (IL)-8, and IL-1β in milk somatic cells were analyzed. RESULTS: Saline solution or prednisolone did not change SCC, LDH activity, and SA and TNF-α concentrations in milk and mRNA expression of TNF-α, IL-1β, and IL-8 in milk somatic cells. The SCC and TNF-α concentration in milk increased similarly in glands infused with LPS, independent of prednisolone administration. However, the increase of LDH activity and SA concentration in milk after LPS infusion was diminished by prednisolone administration. The mRNA expression of TNF-α, IL-8, and IL-1β in milk somatic cells increased after LPS infusion and was unaffected by prednisolone. CONCLUSIONS AND CLINICAL RELEVANCE: Intramammary administration of prednisolone did not induce an immune response and did not change mRNA expression of TNF-α, IL-8, and L-1β during the response to intramammary administration of LPS. However, prednisolone reduced disruption of the blood-milk barrier. This could influence the severity and cure rate of mastitis.
Resumo:
PURPOSE: To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. RESULTS: No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). CONCLUSIONS: Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. CLINICAL APPLICATION: Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.
Resumo:
The vector channel spectral function and the dilepton production rate from a QCD plasma at a temperature above a few hundred MeV are evaluated up to next-to-leading order (NLO) including their dependence on a non-zero momentum with respect to the heat bath. The invariant mass of the virtual photon is taken to be in the range K2 ~ (πT)2 ~ (1GeV)2, generalizing previous NLO results valid for K2 ≫ (πT)2. In the opposite regime 0 < K2 ≪ (πT)2 the loop expansion breaks down, but agrees nevertheless in order of magnitude with a previous result obtained through resummations. Ways to test the vector spectral function through comparisons with imaginary-time correlators measured on the lattice are discussed.
Resumo:
BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.
Resumo:
BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.
Resumo:
Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.
Resumo:
Clin Microbiol Infect ABSTRACT: Invasive aspergillosis (IA) is a live-threatening opportunistic infection that is best described in haematological patients with prolonged neutropenia or graft-versus-host disease. Data on IA in non-neutropenic patients are limited. The aim of this study was to establish the incidence, disease manifestations and outcome of IA in non-neutropenic patients diagnosed in five Swiss university hospitals during a 2-year period. Case identification was based on a comprehensive screening of hospital records. All cases of proven and probable IA were retrospectively analysed. Sixty-seven patients were analysed (median age 60 years; 76% male). Sixty-three per cent of cases were invasive pulmonary aspergillosis (IPA), and 17% of these were disseminated aspergillosis. The incidence of IPA was 1.2/10?000 admissions. Six of ten cases of extrapulmonary IA affected the brain. There were six cases of invasive rhinosinusitis, six cases of chronic pulmonary aspergillosis, and cases three of subacute pulmonary aspergillosis. The most frequent underlying condition of IA was corticosteroid treatment (57%), followed by chronic lung disease (48%), and intensive-care unit stays (43%). In 38% of patients with IPA, the diagnosis was established at autopsy. Old age was the only risk factor for post-mortem diagnosis, whereas previous solid organ transplantation and chronic lung disease were associated with lower odds of post-mortem diagnosis. The mortality rate was 57%.
Resumo:
PURPOSE: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. METHOD: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene's test, one and three-way ANOVA, and Tukey HSD test (alpha = 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram.