2 resultados para pulse Al foil target
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
A new double laser pulse pumping scheme for transient collisionally excited plasma soft X-ray lasers
Resumo:
Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn
Resumo:
Im Jahre 1997 wurden von Tatischeff et al. bei der Reaktion p p -> X p pi+ resonanzartige Zustände im Spektrum der invarianten Masse des fehlenden Nukleons X bei M = 1004, 1044 und 1094 MeV gefunden. In einem zweiten Experiment von Filkov et al. beobachtete man bei der Reaktion p d -> p p X Resonanzstrukturen bei M = 966, 986 und 1003 MeV. Solche exotischen Resonanzen widersprechen etablierten Nukleonenmodellen, die die Delta(1232)-Resonanz als ersten Anregungszustand beschreiben. Zur Deutung der beobachteten Strukturen wurden Quarkcluster-Modelle mit und ohne Farb-Magnet-Wechselwirkungen entwickelt. Lvov et al. zweifelten die experimentellen Ergebnisse an, da keine Strukturen in den Daten zur reellen Comptonstreuung gefunden wurden. Als Gegenargument wurde von Kobushkin vorgeschlagen, dass diese Resonanzen eine total-antisymmetrische Spin-Flavour-Wellenfunktion haben und nur der N-2Gamma-Zerfall erlaubt wäre. In dieser Arbeit wurde die Reaktion g p -> X pi+ -> n g g pi+ zur Suche nach diesen exotischen Resonanzen verwendet. Die Daten wurden parallel zur Messung der Pion-Polarisierbarkeiten am Mainzer Beschleuniger MAMI genommen. Durch Bremsstrahlung der Elektronen an einer Radiatorfolie wurden reelle Photonen erzeugt, deren Energie von der A2-Photonenmarkierungsanlage (Glasgow-Tagger) bestimmt wurde. Als Protontarget wurde ein 10 cm langes Flüssigwasserstoff-Target verwendet. Geladene Reaktionsprodukte wurden unter Vorwärtswinkeln Theta < 20 Grad bezüglich der Strahlachse in einer Vieldraht-Proportionalkammer nachgewiesen, während Photonen im Spektrometer TAPS mit 526 BaF2-Kristallen unter Polarwinkeln Theta > 60 Grad detektiert wurden. Zum Nachweis von Neutronen stand ein Flugzeitdetektor mit insgesamt 111 Einzelmodulen zur Verfügung. Zum Test der Analysesoftware und des experimentellen Aufbaus wurden zusätzlich die Reaktionskanäle g p -> p pi0 und g p -> n pi0 pi+ ausgewertet. Für die Ein-Pion-Produktion wurden differentielle Wirkungsquerschnitte unter Rückwärtswinkeln bestimmt und mit theoretischen Modellen und experimentellen Werten verglichen. Für den Kanal g p -> n pi0 pi+ wurden Spektren invarianter Massen für verschiedene Teilchenkombinationen ermittelt und mit einer Simulation verglichen. Die Daten legen nahe, dass die Reaktion hauptsächlich über eine Anregung der Delta0(1232)-Resonanz verläuft. Bei der Suche nach exotischen Resonanzen wurden keine statistisch signifikanten Strukturen gefunden. Es wurden Obergrenzen für den differentiellen Wirkungsquerschnitt ermittelt.