6 resultados para optical angular momentum

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In dieser Arbeit wird zum Erreichen hoher Kernspinpolarisationen die Methode des metastabilen optischen Pumpens benutzt. Das Verfahren beruht auf dem "Ubertrag des Drehimpulses absorbierter Photonen auf das hierbei angeregte Valenzelektron, welches durch Hyperfeinkopplung den Drehimpuls weiter auf den $^3$He-Kern transferiert. Da der Polarisationsprozess nur bei Dr"ucken von ca. 1~mbar effizient funktioniert, f"ur die meisten Anwendungen aber polarisiertes $^3$He bei einem Druck von $geq 1$~bar ben"otigt wird, muss das Gas nach der Aufpolarisation komprimiert werden. In unserer Arbeitsgruppe steht eine Maschine ("`Polarisator"') zur Verf"ugung, die das Gas polarisiert und anschlie"send komprimiert. Ziel dieser Dissertation ist, einerseits die Leistungsf"ahigkeit des Polarisators bez"uglich Maximalpolarisation und Gasfluss zu verbessern und andererseits den metastabilen Pumpprozess selbst genauer zu untersuchen.\ noindent Durch die Verwendung neuer Laser auf Basis der Fasertechnologie sowie einer systematischen Optimierung der optischen Komponenten konnten in abgeschlossenen Pumpzellen Rekord-Polarisationsgrade von $91pm 2$% erzielt werden.\ noindent Mit der Implementierung neuartiger Optiken und Laser am Mainzer Polarisator konnte die Leistungscharakteristik entscheidend verbessert werden. So wurde die erreichbare Polarisation bei identischer Produktionsrate um 20 Prozentpunkte gesteigert. Zurzeit sind maximale Polarisationsgrade von mehr als 75% im optischen Pumpvolumen erreichbar. Eine am Mainzer Triga-Reaktor durchgef"uhrte Polarisationsbestimmung ergab einen Wert von $72.7pm 0.7$%. Dies veranschaulicht die geringen Polarisationsverluste infolge der Gaskompression, des Transports und einer Lagerung "uber mehrere Stunden.\ noindent Zur Dynamik der geschwindigkeitsver"andernden St"o"se sowie zur Bestimmung der mittleren Photonen-Absorptionsrate wurde ein Modell entwickelt, welches auch experimentell best"atigt wurde. Damit konnte erstmalig das gemessene Absorptionsverhalten einer spektral schmalbandigen Laserdiode korrekt beschrieben werden.\ noindent Zudem stimmen die an so genannten abgeschlossenen Pumpzellen gemessenen extrem hohen Polarisationswerte mit theoretischen Vorhersagen "uberein, sofern der Druck im optischen Pumpvolumen geringer als 1~mbar ist und das $^3$He nicht durch Fremdgase verunreinigt ist. Bei derartigen Pumpzellen ist die gemessene Abh"angigkeit der Polarisation von Laserleistung, Metastabilendichte und falscher Zirkularkomponente mit der Theorie kompatibel.\

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work is to explore, within the framework of the presumably asymptotically safe Quantum Einstein Gravity, quantum corrections to black hole spacetimes, in particular in the case of rotating black holes. We have analysed this problem by exploiting the scale dependent Newton s constant implied by the renormalization group equation for the effective average action, and introducing an appropriate "cutoff identification" which relates the renormalization scale to the geometry of the spacetime manifold. We used these two ingredients in order to "renormalization group improve" the classical Kerr metric that describes the spacetime generated by a rotating black hole. We have focused our investigation on four basic subjects of black hole physics. The main results related to these topics can be summarized as follows. Concerning the critical surfaces, i.e. horizons and static limit surfaces, the improvement leads to a smooth deformation of the classical critical surfaces. Their number remains unchanged. In relation to the Penrose process for energy extraction from black holes, we have found that there exists a non-trivial correlation between regions of negative energy states in the phase space of rotating test particles and configurations of critical surfaces of the black hole. As for the vacuum energy-momentum tensor and the energy conditions we have shown that no model with "normal" matter, in the sense of matter fulfilling the usual energy conditions, can simulate the quantum fluctuations described by the improved Kerr spacetime that we have derived. Finally, in the context of black hole thermodynamics, we have performed calculations of the mass and angular momentum of the improved Kerr black hole, applying the standard Komar integrals. The results reflect the antiscreening character of the quantum fluctuations of the gravitational field. Furthermore we calculated approximations to the entropy and the temperature of the improved Kerr black hole to leading order in the angular momentum. More generally we have proven that the temperature can no longer be proportional to the surface gravity if an entropy-like state function is to exist.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das in dieser Arbeit vorgestellte Experiment zur Messung des magnetischen Moments des Protons basiert auf der Messung des Verhältnisses von Zyklotronfrequenz und Larmorfrequenz eines einzelnen, in einer kryogenen Doppel-Penning Falle gespeicherten Protons. In dieser Arbeit konnten erstmalig zwei der drei Bewegungsfrequenzen des Protons gleichzeitig im thermischen Gleichgewicht mit entsprechenden hochsensitiven Nachweissystemen nicht-destruktiv detektiert werden, wodurch die Messzeit zur Bestimmung der Zyklotronfrequenz halbiert werden konnte. Ferner wurden im Rahmen dieser Arbeit erstmalig einzelne Spin-Übergänge eines einzelnen Protons detektiert, wodurch die Bestimmung der Larmorfrequenz ermöglicht wird. Mithilfe des kontinuierlichen Stern-Gerlach Effekts wird durch eine sogenannte magnetische Flasche das magnetische Moment an die axiale Bewegungsmode des Protons gekoppelt. Eine Änderung des Spinzustands verursacht folglich einen Frequenzsprung der axialen Bewegungsfrequenz, welche nicht-destruktiv gemessen werden kann. Erschwert wird die Detektion des Spinzustands dadurch, dass die axiale Frequenz nicht nur vom Spinmoment, sondern auch vom Bahnmoment abhängt. Die große experimentelle Herausforderung besteht also in der Verhinderung von Energieschwankungen in den radialen Bewegungsmoden, um die Detektierbarkeit von Spin-Übergängen zu gewährleisten. Durch systematische Studien zur Stabilität der axialen Frequenz sowie einer kompletten Überarbeitung des experimentellen Aufbaus, konnte dieses Ziel erreicht werden. Erstmalig kann der Spinzustand eines einzelnen Protons mit hoher Zuverlässigkeit bestimmt werden. Somit stellt diese Arbeit einen entscheidenden Schritt auf dem Weg zu einer hochpräzisen Messung des magnetischen Moments des Protons dar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mit der Erweiterung des Elektronenbeschleunigers MAMI um eine dritte Stufe ist es möglich geworden, am Institut für Kernphysik Teilchen mit offener Strangeness zu produzieren. Für deren Nachweis ist die Drei-Spektrometeranlage der Kollaboration A1 um das von der GSI in Darmstadt übernommene KAOS-Spektrometer erweitert worden. Untersucht wird damit die elementare Reaktion p(e,e' K+)Lambda/Sigma0 wobei das auslaufende Elektron und das Kaon nachgewiesen werden müssen. Wird als Target nicht Wasserstoff verwendet, besteht die Möglichkeit dass sich ein Hyperkern bildet. Spektroskopische Untersuchungen an diesen bieten die Möglichkeit das Potential von Hyperonen in Atomkernen und die Hyperon-Nukleon-Wechselwirkung zu untersuchen. Aufgrund der hervorragenden Strahlqualität bei der Elektroproduktion können hier Massenauflösungen von einigen hundert keV/c² erreicht werden. Mit Hilfe von GEANT4 wurden die Detektoren und die Abbildungseigenschaften des Spektrometers simuliert. Geeignete Ereignisgeneratoren wurden implementiert. Es wurde untersucht, wie mögliche Treffermuster in den Detektoren aussehen, die von einem Trigger auf FPGA-Basis selektiert werden müssen. Ebenso konnte hieraus eine erste Abbildung der Spurkoordinaten auf die Targetkoordinaten und den Teilchenimpuls gewonnen werden. Für das Hyperkernprogramm muss KAOS unter 0° Vorwärtsrichung betrieben werden und der Primärstrahl mit Hilfe einer Schikane durch den Dipol gelenkt werden. Die Simulation zeigt hier eine nur moderate Erhöhung der Strahlenbelastung, vor allem im Bereich des Strahlfängers. Somit ist es möglich, KAOS als doppelseitiges Spektrometer in der Spektrometerhalle zu betreiben. Im Rahmen dieser Arbeit wurden die für sämtliche Detektoren nötige Auslese- und Steuerungselektronik in das vorhandene Datenerfassungssystem und das Steuerungssystem eingebunden. In zwei Strahlzeiten im Herbst 2008 wurden Kaonen im Winkelbereich von 20°-40° mit Impulsen zwischen 400MeV/c und 600MeV/c nachgewiesen. Die aus der Simulation gewonnenen Daten zum Trigger und zur Abbildung kamen zum Einsatz. Es konnte die für eine gute Teilchenidentifikation nötige Zeitauflösung von ca. 1ns FWHM erreicht werden. Die erreichte Winkel- und Impulsauflösung war ausreichend um Lambda und Sigma0-Hyperonen im Spektrum der fehlenden Masse leicht trennen zu können.