27 resultados para metastable optical pumping He-3 Helium-3 polarizer

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wird zum Erreichen hoher Kernspinpolarisationen die Methode des metastabilen optischen Pumpens benutzt. Das Verfahren beruht auf dem "Ubertrag des Drehimpulses absorbierter Photonen auf das hierbei angeregte Valenzelektron, welches durch Hyperfeinkopplung den Drehimpuls weiter auf den $^3$He-Kern transferiert. Da der Polarisationsprozess nur bei Dr"ucken von ca. 1~mbar effizient funktioniert, f"ur die meisten Anwendungen aber polarisiertes $^3$He bei einem Druck von $geq 1$~bar ben"otigt wird, muss das Gas nach der Aufpolarisation komprimiert werden. In unserer Arbeitsgruppe steht eine Maschine ("`Polarisator"') zur Verf"ugung, die das Gas polarisiert und anschlie"send komprimiert. Ziel dieser Dissertation ist, einerseits die Leistungsf"ahigkeit des Polarisators bez"uglich Maximalpolarisation und Gasfluss zu verbessern und andererseits den metastabilen Pumpprozess selbst genauer zu untersuchen.\ noindent Durch die Verwendung neuer Laser auf Basis der Fasertechnologie sowie einer systematischen Optimierung der optischen Komponenten konnten in abgeschlossenen Pumpzellen Rekord-Polarisationsgrade von $91pm 2$% erzielt werden.\ noindent Mit der Implementierung neuartiger Optiken und Laser am Mainzer Polarisator konnte die Leistungscharakteristik entscheidend verbessert werden. So wurde die erreichbare Polarisation bei identischer Produktionsrate um 20 Prozentpunkte gesteigert. Zurzeit sind maximale Polarisationsgrade von mehr als 75% im optischen Pumpvolumen erreichbar. Eine am Mainzer Triga-Reaktor durchgef"uhrte Polarisationsbestimmung ergab einen Wert von $72.7pm 0.7$%. Dies veranschaulicht die geringen Polarisationsverluste infolge der Gaskompression, des Transports und einer Lagerung "uber mehrere Stunden.\ noindent Zur Dynamik der geschwindigkeitsver"andernden St"o"se sowie zur Bestimmung der mittleren Photonen-Absorptionsrate wurde ein Modell entwickelt, welches auch experimentell best"atigt wurde. Damit konnte erstmalig das gemessene Absorptionsverhalten einer spektral schmalbandigen Laserdiode korrekt beschrieben werden.\ noindent Zudem stimmen die an so genannten abgeschlossenen Pumpzellen gemessenen extrem hohen Polarisationswerte mit theoretischen Vorhersagen "uberein, sofern der Druck im optischen Pumpvolumen geringer als 1~mbar ist und das $^3$He nicht durch Fremdgase verunreinigt ist. Bei derartigen Pumpzellen ist die gemessene Abh"angigkeit der Polarisation von Laserleistung, Metastabilendichte und falscher Zirkularkomponente mit der Theorie kompatibel.\

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Der Bedarf an hyperpolarisiertem 3He in Medizin und physikalischer Grundlagenforschung ist in den letzten ca. 10-15 Jahren sowohl in Bezug auf die zu Verfügung stehende Menge, als auch auf den benötigten Grad der Kernspinpolarisation stetig gestiegen. Gleichzeitig mußten Lösungen für die polarisationserhaltende Speicherung und den Transport gefunden werden, die je nach Anwendung anzupassen waren. Als Ergebnis kann mit dieser Arbeit ein in sich geschlossenes Gesamtkonzept vorgestellt werden, daß sowohl die entsprechenden Mengen für klinische Anwendungen, als auch höchste Polarisation für physikalische Grundlagenfor-schung zur Verfügung stellen kann. Verschiedene unabhängige Polarimetriemethoden zeigten in sich konsistente Ergebnisse und konnten, neben ihrer eigenen Weiterentwicklung, zu einer verläßlichen Charakterisierung des neuen Systems und auch der Transportzellen und –boxen eingesetzt werden. Die Polarisation wird mittels „Metastabilem Optischen Pumpen“ bei einem Druck von 1 mbar erzeugt. Dabei werden ohne Gasfluß Werte von P = 84% erreicht. Im Flußbetrieb sinkt die erreichbare Polarisation auf P ≈ 77%. Das 3He kann dann weitgehend ohne Polarisationsver-luste auf mehrere bar komprimiert und zu den jeweiligen Experimenten transportiert werden. Durch konsequente Weiterentwicklung der vorgestellten Polarisationseinheit an fast allen Komponenten kann somit jetzt bei einem Fluß von 0,8 barl/h eine Polarisation von Pmax = 77% am Auslaß der Apparatur erreicht werden. Diese skaliert linear mit dem Fluß, sodaß bei 3 barl/h die Polarisation immer noch bei ca. 60% liegt. Dabei waren die im Rahmen dieser Arbeit durchgeführten Verbesserungen an den Lasern, der Optik, der Kompressionseinheit, dem Zwischenspeicher und der Gasreinigung wesentlich für das Erreichen dieser Polarisatio-nen. Neben dem Einsatz eines neuen Faserlasersystems ist die hohe Gasreinheit und die lang-lebige Kompressionseinheit ein Schlüssel für diese Leistungsfähigkeit. Seit Herbst 2001 er-zeugte das System bereits über 2000 barl hochpolarisiertes 3He und ermöglichte damit zahl-reiche interdisziplinäre Experimente und Untersuchungen. Durch Verbesserungen an als Prototypen bereits vorhandenen Transportboxen und durch weitgehende Unterdrückung der Wandrelaxation in den Transportgefäßen aufgrund neuer Erkenntnisse über deren Ursachen stellen auch polarisationserhaltende Transporte über große Strecken kein Problem mehr dar. In unbeschichteten 1 Liter Kolben aus Aluminosilikatglä-sern werden nun problemlos Speicherzeiten von T1 > 200h erreicht. Im Rahmen des europäi-schen Forschungsprojektes „Polarized Helium to Image the Lung“ wurden während 19 Liefe-rungen 70barl 3He nach Sheffield (UK) und bei 13 Transporten 100 barl nach Kopenhagen (DK) per Flugzeug transportiert. Zusammenfassend konnte gezeigt werden, daß die Problematik der Kernspinpolarisationser-zeugung von 3He, die Speicherung, der Transport und die Verwendung des polarisierten Ga-ses in klinischer Diagnostik und physikalischen Grundlagenexperimenten weitgehend gelöst ist und das Gesamtkonzept die Voraussetzungen für allgemeine Anwendungen auf diesen Gebieten geschaffen hat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen meiner Dissertation wurde ein 3He-Applikationssystem für die in-vivo 3He-Magnetresonanztomographie der Lunge von Ratten entwickelt. Im Gegensatz zu anderen bisher entwickelten MR-kompatiblen Beatmungsgeräten wurde in diesem Applikationssystem erstmals der polarisationserhaltende ³He-Langzeitspeicher im Streufeld des Tomographen integriert. Bei der 3He-Applikation wird das 3He-Gas automatisch aus dem Langzeitspeicher außerhalb des Magneten zum Tier in den Tomographen geleitet. Die Kernspin-Polarisationsverluste, die beim 3He-Transfer zum Tier in den Tomographen auftreten, betragen etwa 1% (rel.) und sind vernachlässigbar gering. Das Beatmungssystem wurde zusammen mit der MRT-Bildgebungssequenz COMSPIRA an mehr als 200 Tieren erfolgreich getestet. Die MRT-Aufnahmen fanden hauptsächlich an einem 0,47 T Niederfeldtomographen bei der Firma Boehringer-Ingelheim Pharma in Biberach statt. Es wurden sowohl morphologische Aufnahmen der Rattenlunge gemacht als auch der „Apparent Diffusion Coefficient“ (ADC) gemessen. Die relative Streuung der ADC-Werte innerhalb einer Gruppe von Tieren ähnlichen Alters und Gewichts betrug dabei 5%. Bei Wiederholungsmessungen an ein und demselben Tier verringerte sich die relative Streuung auf 1%. Diese Werte unterstreichen die hohe Reproduzierbarkeit des Beatmungssystems sowie des gesamten Messverfahrens. Weiterhin wurde ein Verfahren vorgestellt, das den experimentell bestimmten ADC unabhängig von dem Mischungsverhältnis zwischen dem applizierten 3He und der Atemluft in der Lunge macht. Dies kann erreicht werden, indem das hp 3He mit dem chemisch inerten und ungiftigen Gas SF6 in einem definierten Verhältnis gemischt wird und anschließend dem Tier appliziert wird. Zuletzt wurde der ADC von emphysematischen Rattenlungen und von gesunden Rattenlungen gemessen. Die Ergebnisse zeigten einen signifikant kleineren ADC innerhalb der Gruppe der erkrankten Tiere. Diese Dissertation wurde durch die Boehringer-Ingelheim Pharma GmbH & Co. KG unterstützt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zusammenfassung: Michael EbertEntwicklung eines leistungsstarken Polarisators und Kompressorsfür 3-He für medizinische MR Tomographie Durch Optisches Pumpen von metastabilem3-He*--Gas bei einem Druck von 1 mb und Spinübertrag mittels Metastabileraustauschstöße aufden Grundzustand, wird 3-He auf 53 % bei einemmittleren Fluß von f = 58 bar*liter/Tag aufpolarisiert. Bei einem Fluß von f = 122bar*l/Tag wird immer noch eine Polarisation von 30 % erzielt. DurchSteigerung der Laserleistung von derzeit 12 Watt aufwünschenswerte 30 Watt, könnten beigleichem Fluß Kernspinpolarisationen des Heliums von 70 % erreicht werden. Mittels einer eigens entwickelten Ganzmetall--Titan--Kolbenpumpeerfolgt die Kompression in zwei Stufen. Zuerst wird einZwischenvolumen auf Drücke 200 bis 800 mb,je nach Anwendung gefüllt. Mit dem selben Kompressor könnenanschließend abnehmbare, verschließbare Experimentierzellen ausdiesem Zwischenvolumen auf Drücke 1 bis 6 bar gefüllt werden. Auf Grund des großen Hubvolumens von 15,4 Liter können große Gasmengen proKompressionszyklus verdichtet werden. Wegen des großen Verhältnisaus Kompressionshub h = 100 cm undKompressordurchmesser 14 cm kommt es imKompressionsraum zu keinen meßbaren Polarisationsverlusten.Zusammen mit dem großen Kompressionsfaktor von K = 10000sind diese konstruktiven Maßnahmen für den vollständigen Erhaltder Polarisation bei der Kompression des polarizierten 3-He--Gasesverantwortlich. Diese großen Gasmengen an hyperpolarisiertem 3-He haben ersteklinische Studien funktioneller Lungen--MRT ermöglicht. DurchMessung des Sauerstoffpartialdrucks und dessen Abnahmerate, derBestimmung der Ventillation und Messung der DiffusionskonstantenADC in der Lunge, können die Funktionen dieses Organs lokalquantitativ beurteilt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Machbarkeit der Detektion einer P,T-Verletzung in der Neutron-Kern-p-Wellenresonanz von La-139 wird untersucht. Als experimentelleVerbesserung wurde der He-3- Neutronenspin- Filter (He-3-NSF) getestet. Mit einem He-3-NSF als Polarisationsanalysator wurde die rein P-verletzende Neutronenspin-Rotation in 139La erstmals mit guter Genauigkeit unmittelbar in der Resonanz bestimmt. Das schwache Matrixelement betrug v=1.51(5)stat(7)syst meV. Es wurde ein adiabatischer He-3-Spin-Rotator entwickelt und erfolgreich getestet, welcher es erlaubt, die Richtung der He-3-Polarisation einzustellen. Dies kann die bei Polarisationsmessungen üblichen Spinpräzessionsspulen ersetzen. Das Problem der Unterdrückung apparativer Falscheffekte während einer P,T-Detektion wird diskutiert und konnte jedoch noch nicht gelöst werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies in regions of the nuclear chart in which the model predictions of properties of nuclei fail can bring a better understanding of the strong interaction in the nuclear medium. To such regions belongs the so called "island of inversion" centered around Ne, Na and Mg isotopes with 20 neutrons in which unexpected ground-state spins, large deformations and dense low-energy spectra appear. This is a strong argument that the magic N = 20 is not a closed shell in this area. In this thesis investigations of isotope shifts of stable 24,25,26Mg, as well as spins and magnetic moments of short-lived 29,31Mg are presented. The successful studies were performed at the ISOLDE facility at CERN using collinear laser and beta-NMR spectroscopy techniques. The isotopes were investigated as single-charged ions in the 280-nm transition from the atomic ground state 2S1/2 to one of the two lowest excited states 2P1/2,3/2 using continuous wave laser beams. The isotope-shift measurements with fluorescence detection for the three stable isotopes show that it is feasible to perform the same studies on radioactive Mg isotopes up to the "island of inversion". This will allow to determine differences in the mean charge square radii and interpret them in terms of deformation. The high detection efficiency for beta particles and optical pumping close to saturation allowed to obtain very good beta-asymmetry signals for 29Mg and 31Mg with half-lives around 1 s and production yields about 10^5 ions/s. For this purpose the ions were implanted into a host crystal lattice. Such detection of the atomic resonances revealed their hyperfine structure, which gives the sign and a first estimate of the value of the magnetic moment. The nuclear magnetic resonance gave also their g-factors with the relative uncertainty smaller than 0.2 %. By combining the two techniques also the nuclear spin of both isotopes could be unambiguously determined. The measured spins and g-factors show that 29Mg with 17 neutrons lies outside the "island of inversion". On the other hand, 31Mg with 19 neutrons has an unexpected ground-state spin which can be explained only by promoting at least two neutrons across the N = 20 shell gap. This places the above nucleus inside the "island". However, modern shell-model approaches cannot predict this level as the ground state but only as one of the low-lying states, even though they reproduce very well the experimental g-factor. This indicates that modifications to the available interactions are required. Future measurements include isotope shift measurements on radioactive Mg isotopes and beta-NMR studies on 33Mg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen meiner Dissertation habe ich gemäß dem Medizinproduktegesetz ein MR-kompatibles Verabreichungsgerät entwickelt, um Patienten hyperpolarisierte Gas Boli (He-3, Xe-129) als Kontrasgas zur MRT der Lunge zu applizieren. Das Gerät wurde dazu optimiert, die Gase oder Gasmischungen (z. B. HP Gas + N2) in definierten Mengen und zu definierten Zeitpunkten während der Inspiration mit hoher Reproduzierbarkeit und Zuverlässigkeit zu verabreichen, ohne dabei die MR-Qualität zu beeinträchtigen. Aus Sicherheitsgründen und zur späteren Datenanalyse werden die Atemflusskurven der Patienten kontinuierlich angezeigt und aufgezeichnet. Ein Kolbenkompressor ist integriert, um die gesamte gespeicherte He-3-Menge nutzen zu können. Weiterhin ist es möglich, die Polarisation vor Ort zu bestimmen und das abgeatmete He-3 zur späteren Rückgewinnung aufzufangen. Diese Auffangeffizienz konnte durch Untersuchungen mit He-4 (als He-3-Ersatz) gesteigert werden.rnDie ersten MR-Aufnahmen von 10 gesunden Probanden wurden mit diesem Aufbau imrnRahmen einer klinischen Studie durchgeführt. Die Analyse der bestimmten MR-Parameter Signal-Rausch-Verhältnis (SNR), Sauerstoffpartialdruck (pO2), Scheinbarer Diffusionskoeffizient (ADC=apparent diffusion coefficient) sowie die Signalanstiegszeit (rise-time) zeigt eine deutlich bessere Reproduzierbarkeit bei der Verabreichung des He-3 mit dem Applikators anstelle eines Tedlarbags (= kleine heliumdichte Plastiktüte).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die differentielle Hyperfeinanomalie beschreibt den Isotopieeffekt der magnetischen Hyperfeinwechselwirkung und stellt eine Testmöglichkeit für Kernmodelle dar. Nachdem in einer Reihe von Messungen die A-Faktoren der Hyperfeinwechselwirkung im Grundzustand von zwei stabilen und fünf instabilen Europium-Isotopen bestimmt wurden, sollen nun die Kern-g-Faktoren der gleichen Isotope bestimmt werden.Um die Kern-g-Faktoren zu bestimmen, wurden zunächst die Termschemata des Grundzustandesder stabilen Isotope 151,153Eu+ simuliert. Wegen der hohen Kern- und Hüllenspins I=5/2, J=4 ergeben sich 54 Zeemanzustände und ein komplexes optisches Spektrum.Etwa 10^6 Ionen der beiden stabilen Isotope 151,153Eu+ werden in einer Penningfalle beieinem Magnetfeld von ca. 1.5T gespeichert. Durch Puffergas und Anregung einer Seitenbandfrequenzder Ionenbewegung wird optisches Pumpen in metastabile D-Zustände bei gleichzeitiger Kühlung der Ionenwolke verhindert.Bei Verstimmung eines frequenzverdoppelten Ti:Sa-Lasers wurde die Ionenfluoreszenz aufgenommen. Durch die Simulation der optischen Spektren gelang es, einzelne Übergänge des Isotopes 151Eu+ zu identifizieren. Mit Laser/Mikrowellen-Doppelresonanzmessungen erhält man ein in erster Ordnung dopplerfreies Mikrowellenspektren eines Überganges zwischen zwei Zeemanzuständen im Grundzustand.Durch Messung der Übergangsfrequenzen von insgesamt fünf Delta mI=+1 Übergängen und Bestimmung des Magnetfeldes durch Messung der Zyklotronfrequenz gespeicherter Elektronen konnte der gI-Faktor des Isotopes151Eu zu 151gI = 1.37734(6) bestimmt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Collinear laser spectroscopy has been used as a tool for nuclear physics for more than 30 years. The unique possibility to extract nuclear properties like spins, radii and nuclear moments in a model-independent manner leads to important physics results to test the predictive power of existing nuclear models. rnThis work presents the construction and the commissioning of a new collinear laser spectroscopy experiment TRIGA-LASER as a part of the TRIGA-SPEC facility at the TRIGA research reactor at the University of Mainz. The goal of the experiment is to study the nuclear structure of radioactive isotopes which will be produced by neutron-induced fission near the reactor core and transported to an ion source by a gas jet system. rnThe versatility of the collinear laser spectroscopy technique will be exploited in the second part of this thesis. The nuclear spin and the magnetic moment of the neutron-deficient isotope Mg-21 will be presented, which were measured by the detection of the beta-decay asymmetry induced by nuclear polarization after optical pumping. A combination of this detection method with the classical fluorescence detection is then used to determine the isotope shifts of the neutron-rich magnesium isotopes from Mg-24 through Mg-32 to study the transition to the ''island of inversion''.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Im Jahr 1996 wurde die erste Aufnahme der menschlichen Lunge in einem Kernspintomographen unter Benutzung des hyperpolarisierten Edelgases ³He als Kontrastgas veröffentlicht. Es folgten zahlreiche medizinische Studien mit diesem neuen Lungenbildgebungsverfahren. Als Konsequenz aus dem steigenden Bedarf an hyperpolarisiertem ³He wurde am Institut für Physik der Universität Mainz ein ³He-Polarisator entwickelt, der die Versorgung dieser Studien mit polarisiertem Gas gewährleistet. Für den Fall jedoch, dass die Lungenbildgebung mit hyperpolarisiertem ³He in die medizinische Praxis übernommen wird, wären die Produktionskapazitäten der bestehenden Anlage nicht mehr ausreichend. Daher wurde im Rahmen dieser Arbeit ein kompaktes System zum Polarisieren von ³He direkt am Einsatzort entwickelt, welches als eine Art Industrieprodukt in beliebiger Stückzahl nachgebaut werden kann. So steht nun ein kompakter, mobiler ³He Polarisator zur Verfügung, dessen Produktionsrate in der Größenordnung eines Standardliters (1 l, 1 bar, Raumtemperatur) pro Stunde bei einer Polarisation von > 60% liegt.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Realisierung des 3He-Kreislaufs zur 3He-Magnet-Resonanz-Tomographie In der vorliegenden Dissertation wurde ein 3He-Kreislauf für die 3He-Magnet-Resonanz-Tomographie realisiert. Dazu wurde eine einfache Methode entwickelt, mit deren Hilfe es möglich ist,die Kernspinpolarisation von hyperpolarisiertem 3He bei hohen Drucken zu bestimmen.Bei einem Druck von ca. 3 bar konnte die Polarisation bis auf einen relativen Fehlervon etwa 5 % genau bestimmt werden. Zum Transport des polarisierten 3He wurden Magnetfelder konstruiert, die in einem Volumenbis zu V = 13,8 l ein homogenes Führungsfeld bereitstellen. Diese besitzen eineabschirmende Wirkung auf äußere Felder, und die benötigten magnetischen Flußdichten vonetwa 8 Gauá werden durch Permanentmagneten erzeugt. Bei geschwindigkeitsgewichteten Untersuchungen an zylindrischen Phantomen und Probandenkonnte laminare Strömung von 3He-Luftgemischen mit der Methode der 3He-vMRT bestimmtwerden. Bei zweidimensionalen Untersuchungen ließen sich laminare Strömungsprofile mitihren absoluten, ortsabhängigen Geschwindigkeiten ermitteln, während eindimensionalenMessungen ebenfalls laminare Strömungsprofile zeigten. Mit einer eigens entwickelten He-Aufbereitung wurden bis zu 95,8 % des eingeatmetenHeliums aus dem ausgeatmeten Gas zurückgewonnen. Der Anfangsgehalt an Helium betrugetwa 2 % und konnte um mehr als 6 Größenordnungen angereichert werden. Die Gasreinheitreichte aus, um eine erneute Polarisation des 3He zu ermöglichen. Die erreichteMaximalpolarisation lag dabei nur geringfügig unter der mit originalem 3He.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Durch die Möglichkeit, gleichzeitig mehrere Polarisationsfreiheitsgradernin der quasi-elastischen Elektronstreuung an $^3mathrm{He}$ zurnmessen, bietet sich ein neuer experimenteller Zugang zu kleinen, aber rnwichtigen Partialwellenbeiträgen ($S'$, $D$-Welle) desrn$^3mathrm{He}$-Grundzustands. Dies ermöglicht nicht nur ein tieferesrnVerständnis des Drei-Körper-Systems, sondern bietet auch diernMöglichkeit, Erkenntnisse über die $^3mathrm{He}$-Struktur undrnDynamik zu erlangen. Mit Hilfe dieser Informationen lassen sich abrninitio Rechnungen testen, sowie Korrekturen berechnen, die für anderernExperimente (z.B. Messung von $G_{en}$) benötigt werden. rnrnModerne Faddeev-Rechnungen liefern nicht nur eine quantitativernBeschreibung des $^3mathrm{He}$-Grundzustands, sondern geben auchrneinen Einblick in die sogenannten spinabhängigenrnImpulsverteilungen. Eine gründliche experimentelle Untersuchung ist in rndiesem Zusammenhang nötig, um eine solide Basis für die Üperprüfungrnder theoretische Modelle zu liefern. EinrnDreifach-Polarisationsexperiment liefert hier zum einen wichtigernDaten, zum anderen kann damit untersucht werden, ob mit der Methoderndes glqq Deuteron-Tagginggrqq polarisiertes $^3mathrm{He}$ alsrneffektives polarisiertes Protonentarget verwendet werden kann. rnrnDas hier vorgestellte Experiment kombiniert erstmals Strahl- undrnTargetpolarisation sowie die Messung der Polarisation des auslaufendenrnProtons. Das Experiment wurde im Sommer 2007 an derrnDrei-Spektrometer-Anlage der A1-Kollaboration an MAMI rndurchgeführt. Dabei wurde mit einer Strahlenergie vonrn$E=855,mathrm{MeV}$ bei $q^2=-0,14,(mathrm{GeV/c})^2$rn$(omega=0,13,mathrm{GeV}$, $q=0,4,mathrm{GeV/c})$ gemessen.rnrnDie bestimmten Wirkungsquerschnitte, sowie die Strahl-Target- und diernDreifach-Asymmetrie werden mit theoretischen Modellrechnungen vonrnJ. Golak (Plane Wave Impuls Approximation PWIA, sowie ein Modell mitrnEndzustandswechselwirkung) verglichen. Zudem wurde das Modell von dernForest verwendet, welches den Wirkungsquerschnitt über eine gemessenernSpektralfunktion berechnet. Der Vergleich mit den Modellrechnungenrnzeigt, dass sowohl der Wirkungsquerschnitt, als auch die Doppel- undrnDreifach-Asymmetrie gut mit den theoretischen Rechnungenrnübereinstimmen. rnrnDie Ergebnisse dieser Arbeit bestätigen, dass polarisiertesrn$^3mathrm{He}$ nicht nur als polarisiertes Neutronentarget, sondernrndurch Nachweis des Deuterons ebenfalls als polarisiertesrnProtonentarget verwendet werden kann.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Die Messung eines möglichen elektrischen Dipolmoments des freien Neutrons erfordert genaustmögliche Kenntnis und Überwachung des magnetischen Feldes im Inneren der n2EDM-Spektrometerkammer. Die freie Spinpräzession von hyperpolarisiertem ³He kann verbunden mit einer Signalauslese mittels optisch gepumpter Cs-Magnetometer dazu genutzt werden, Messempfindlichkeit auf Magnetfeldschwankungen im Bereich weniger Femto-Tesla zu erhalten. Am Institut für Physik der Universität Mainz wurde eine ³He/Cs-Testanlage aufgebaut, um die Möglichkeiten der Signalauslese der ³He-Spinpräzession mittels eines lampengepumpten Cs-Magnetometers zu untersuchen. Darüber hinaus wurde eine ultrakompakte und transportable Polarisationseinheit entwickelt und installiert, welche ermöglicht, eine ³He-Hyperpolarisation von bis zu 55 Prozent zu erreichen. Im Anschluss wird das polarisierte 3He-Gas automatisiert komprimiert und in zwei Magnetometerzellen in Sandwichanordnung innerhalb der n2EDM-Spektrometerkammer gefüllt. In dieser Arbeit werden die Ergebnisse der ersten im Januar 2012 erfolgreich durchgeführten Messungen vorgestellt. Bei diesen Messungen wurde ³He-Gas in der ultrakompakten Polarisationseinheit hyperpolarisiert und über Führungsfelder eines Transfersystems in eine vierlagige Mumetall-Abschirmung transferiert. Im Anschluss konnte im Inneren der magnetischen Abschirmung die freie ³He-Spinpräzession mittels eines lampengepumpten Cs-Magnetometer eindeutig nachgewiesen werden.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Diese Arbeit beschreibt die Entwicklung, Konstruktion und Untersuchung eines Magnetometers zur exakten und präzisen Messung schwacher Magnetfelder. Diese Art von Magnetometer eignet sich zur Anwendung in physikalischen hochpräzisions Experimenten wie zum Beispiel der Suche nach dem elektrischen Dipolmomentrndes Neutrons. Die Messmethode beruht auf der gleichzeitigen Detektion der freien Spin Präzession Kern-Spin polarisierten 3He Gases durch mehrere optisch gepumpte Cäsium Magnetometer. Es wird gezeigt, dass Cäsium Magnetometer eine zuverlässige und vielseitige Methode zur Messung der 3He Larmor Frequenz und eine komfortable Alternative zur Benutzung von SQUIDs für diesen Zweck darstellen. Ein Prototyp dieses Magnetometers wurde gebaut und seine Funktion in der magnetisch abgeschirmten Messkabine der Physikalisch Technischen Bundesanstalt untersucht. Die Sensitivität des Magnetometers in Abhängigkeitrnvon der Messdauer wurde experimentell untersucht. Es wird gezeigt, dass für kurze Messperioden (< 500s) Cramér-Rao limitierte Messungen möglich sind während die Sensitivität bei längeren Messungen durch die Stabilität des angelegten Magnetfeldes limitiert ist. Messungen eines 1 muT Magnetfeldes mit einer relative Genauigkeit von besser als 5x10^(-8) in 100s werden präsentiert. Es wird gezeigt, dass die Messgenauigkeit des Magnetometers durch die Zahl der zur Detektion der 3He Spin Präzession eingesetzten Cäsium Magnetometer skaliert werden kann. Prinzipiell ist dadurch eine Anpassung der Messgenauigkeit an jegliche experimentellen Bedürfnisse möglich. Es wird eine gradiometrische Messmethode vorgestellt, die es erlaubt den Einfluss periodischerrnmagnetischer Störungen auf dieMessung zu unterdrücken. Der Zusammenhang zwischen der Sensitivität des kombinierten Magnetometers und den Betriebsparametern der Cäsium Magnetometer die zur Spin Detektion verwendet werden wird theoretisch untersucht und anwendungsspezifische Vor- und Nachteile verschiedener Betriebsartenwerden diskutiert. Diese Zusammenhänge werden in einer Formel zusammengefasst die es erlaubt, die erwartete Sensitivität des Magnetometers zu berechnen. Diese Vorhersagen befinden sich in perfekter Übereinstimmung mit den experimentellen Daten. Die intrinsische Sensitivität des Magnetometer Prototyps wird auf Basis dieser Formel theoretisch bestimmt. Ausserdem wird die erwartete Sensitivität für die Anwendung im Rahmen des Experiments der nächsten Generation zur Bestimmung des elektrischenrnDipolmoments des Neutrons am Paul Scherrer Institut abgeschätzt. Des weiteren wird eine bequeme experimentelle Methode zur Messung des Polarisationsgrades und des Rabi Flip-Winkels der 3He Kernspin Polarisation vorgestellt. Letztere Messung ist sehr wichtig für die Anwendung in hochpräzisions Experimenten.