14 resultados para ion beam implantation

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

90.00% 90.00%

Publicador:

Resumo:

REX-ISOLDE ist ein Pilotexperiment zur Nachbeschleunigung radioaktiver Ionenstrahlen am on-line Massenseparator ISOLDE am CERN. Ein wichtiges Teilprojekt war die Realisierung der effizienten Umwandlung des kontinuierlichen niederenergetischen Ionenstrahles in kurze Ionenpulse hoher Qualität. Zu diesem Zweck wurde im Rahmen dieser Arbeit REXTRAP, eine gasgefüllte Penningfalle entwickelt, in Betrieb genommen und systematisch untersucht.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This doctoral thesis describes the extension of the resonance ionization laser ion source RILIS at CERN/ISOLDE by the addition of an all-solid state tunable titanium:sapphire (Ti:Sa) laser system to complement the well-established system of dye lasers. Synchronous operation of the so called Dual RILIS system of Ti:Sa and dye lasers was investigated and the potential for increased ion beam intensity, reliability, and reduced setup time has been demonstrated. In-source resonance ionization spectroscopy was performed at ISOLDE/CERN and at ISAC/TRIUMF radioactive ion beam facilities to develop an efficient and selective three-colour ionization scheme for the purely radioactive element astatine. A LabVIEW based monitoring, control and measurement system was conceived which enabled, in conjunction with Dual RILIS operation, the spectroscopy of high lying Rydberg states, from which the ionization potential of the astatine atom was determined for the first time experimentally.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An dem Schwerionenspeicherring TSR (MPI für Kernphysik, Heidelberg) wurde ein 7 Li +-Ionenstrahl geringer Dichte durch RF-Bunchen und Laserkühlung präpariert.Die Phasenraumverteilung in dem Strahl wurde durch Laser- spektroskopie an Ionen im metastabilen Zustand untersucht. Ein umlaufsynchrones, zeitaufgelöstes Meßverfahren für das Fluoreszenzlicht ermöglichte die Bestimmung der räumlichen Struktur mit dieser rein optischen Methode.Durch einen speziellen Präparationsschritt wurden die Ionen im Grundzustand aus dem Speicherring entfernt. Der sonst dominierende Heizeffekt der strahlinternen Streuung war dadurch vernachlässigbar und es konnte eine Temperatur von 160 mK erreicht werden.Der präparierte Ionenstrahl bietet besondere Eigenschaften im Hinblick auf Präzisionsexperimente, bei denen mit möglichst ungestörten Ionen gearbeitet werden soll. Es wird gezeigt, daß die Phasenraumverteilung der Ionen nicht mehr durch Ion-Ion-Wechselwirkungen bestimmt ist und daß der verbleibende Heizmechanismus durch die Streuung am Restgas erklärt werden kann.1993 wurde durch Laserspektroskopie an 7 Li + im TSR die spezielle Relativitätstheorie im Hinblick auf die relativistische Zeitdilatation experimentell getestet. In diesem Zusammenhang wird das zu erwartende Ergebnis eines Experimentes diskutiert, das, basierend auf den in dieser Arbeit vorgestellten Verfahren, einen erneuten Test der relativistischen Zeitdilatation mit verbesserter Genauigkeit durchführen könnte.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to its high Curie temperature of 420K and band structure calculations predicting 100% spin polarisation, Sr2FeMoO6 is a potential candidate for spintronic devices. However, the preparation of good quality thin films has proven to be a non-trivial task. Epitaxial Sr2FeMoO6 thin films were prepared by pulsed laser deposition on different substrates. Differing from previous reports a post-deposition annealing step at low oxygen partial pressure (10-5 mbar) was introduced and enabled the fabrication of reproducible, high quality samples. According to the structural properties of the substrates the crystal structure and morphology of the thin films are modified. The close interrelation between the structural, magnetic and electronic properties of Sr2FeMoO6 was studied. A detailed evaluation of the results allowed to extract valuable information on the microscopic nature of magnetism and charge transport. Smooth films with a mean roughness of about 2 nm have been achieved, which is a pre-requisite for a possible inclusion of this material in future devices. In order to establish device-oriented sub-micron patterning as a standard technique, electron beam lithography and focussed ion beam etching facilities have been put into operation. A detailed characterisation of these systems has been performed. To determine the technological prospects of new spintronics materials, the verification of a high spin polarisation is of vital interest. A popular technique for this task is point contact Andreev reflection (PCAR). Commonly, the charge transport in a transparent metal-superconductor contact of nanometer dimensions is attributed solely to coherent transport. If this condition is not fulfilled, inelastic processes in the constriction have to be considered. PCAR has been applied to Sr2FeMoO6 and the Heusler compound Co2Cr0.6Fe0.4Al. Systematic deviations between measured spectra and the standard models of PCAR have been observed. Therefore existing approaches have been generalised, in order to include the influence of heating. With the extended model the measured data was successfully reproduced but the analysis has revealed grave implications for the determination of spin polarisation, which was found to break down completely in certain cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Metallische Objekte in der Größenordnung der optischen Wellenlänge zeigen Resonanzen im optischen Spektralbereich. Mit einer Kombination aus Kolloidlithographie, Metallfilmbedampfung und reaktivem Ionenstrahl¨atzen wurden Nanosicheln aus Gold bzw. Silber mit identischer Form und Orientierung in Sichelform mit einer Größe von 60nm bis 400nm hergestellt. Der Öffnungswinkel der Nanosicheln lässt sich kontinuierlich einstellen. Durch die einheitliche Orientierung lassen sich Messungen am Ensemble direkt auf das Verhalten des Einzelobjektes übertragen, wie ein Vergleich der Extinktionsspektren einer Ensemblemessung am UV/Vis/NIR-Spektrometer mit einer Einzelpartikelmessung in einem konfokalen Mikroskop zeigt. Die optische Antwort der Nanosicheln wurde als zwei-dimensionales Modell mit einer Finite Elemente Methode berechnet. Das Ergebnis sind mehrere polarisationsabhängige Resonanzen im optischen Spektrum. Diese lassen sich durch Variation des Öffnungswinkels und der Gr¨oße der Nanosichel verschieben. Durch Beleuchten lassen sich plasmonische Schwingungen anregen, die ein stark lokalisiertes Nahfeld an den Spitzen und in der Öffnung der Nanosicheln erzeugen. Das Nahfeld der Partikelresonanz wurde mit einer Fotolackmethode nachgewiesen. Die Untersuchungen am UV/Vis/NIR-Spektrometer zeigen mehrere polarisationsabhängige Resonanzen im Spektralbereich von 300 nm bis 3200 nm. Die Resonanzen der Nanosicheln lassen sich durch den Öffnungswinkel und den Durchmesser in der Größenordnung der Halbwertbreite im optischen Spektrum verschieben. In der Anwendung als Chemo- bzw. Biosensor zeigen Gold-Nanosicheln eine ähnliche Empfindlichkeit wie vergleichbare Sensoren auf der Basis von dünnen Metallstrukturen. Das Nahfeld zeichnet sich durch eine starke Lokalisierung aus und dringt, je nach Multipolordnung, zwischen 14 nm und 70 nm in die Umgebung ein. Quantenpunkte wurden an das Nahfeld der Nanosicheln gekoppelt. Die Emission der Quantenpunkte bei einer Wellenlänge von 860nm wird durch die Resonanz der Nanosicheln verstärkt. Die Nanosicheln wurden als optische Pinzette eingesetzt. Bei einer Anregung mit einem Laser bei einer Wellenlänge von 1064 nm wurden Polystyrolkolloide mit einem Durchmesser von 40 nm von den resonanten Nanosicheln eingefangen. Die Nanosicheln zeigen außergewöhnliche optische Eigenschaften, die mithilfe der Geometrieparameter über einen großen Bereich verändert werden können. Die ersten Anwendungen haben Anknüpfungspunkte zur Verwendung in der Sensorik, Fluoreszenzspektroskopie und als optische Pinzette aufgezeigt.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new method to measure the sulfur isotopic composition of individual aerosol particles by NanoSIMS has been developed and tested on several standards such as barite (BaSO4), anhydrite (CaSO4), gypsum (CaSO4·2H2O), mascagnite ((NH4)2SO4), epsomite (MgSO4·7H2O), magnesium sulfate (MgSO4·xH2O), thenardite (Na2SO4), boetite (K2SO4) and cysteine (an amino acid). This ion microprobe technique employs a Cs+ primary ion beam and measures negative secondary ions permitting the analysis of sulfur isotope ratios in individual aerosol particles down to 500 nm in size (0.001-0.5 ng of sample material). The grain-to-grain reproducibility of measurements is typically 5‰ (1σ) for micron-sized grains, <5‰ for submicron-sized grains, and <2‰ for polished thin sections and ultra microtome sections which were studied for comparison. The role of chemical omposition (matrix effect) and sample preparation techniques on the instrumental mass fractionation (IMF) of the 34S/32S ratio in the NanoSIMS has been investigated. The IMF varies by ~15‰ between the standards studied here. A good correlation between IMF and ionic radius of the cations in sulfates was observed. This permits to infer IMF corrections even for sulfates for which no isotope standards are available. The new technique allows to identify different types of primary and secondary sulfates based on their chemical composition and to measure their isotopic signature separately. It was applied to marine aerosol samples collected in Mace Head and urban aerosol samples collected in Mainz. It was shown that primary sulfate particles such as sulfate in NaCl or gypsum particles precipitated from ocean water retain the original isotopic signature of their source. The isotopic composition of secondary sulfate depends on the isotopic composition of precursor SO2 and the oxidation pathway. The 34S/32S fractionation with respect to the precursor SO2 is -9‰ for homogeneous oxidation and +16.5‰ for heterogeneous oxidation. This large difference between the isotopic fractionation of both pathways allows identifying the oxidation pathway from which the SO42- in a secondary sulfate particle is derived, by means of its sulfur isotope ratio, provided that the isotopic signature of the precursor SO2 is known. The isotopic composition of the precursor SO2 of secondary sulfates was calculated based on the isotopic composition of particles with known oxidation pathway such as fine mode ammonium sulfate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the field of organic optoelectronics, the nanoscale structure of the materials has huge im-pact on the device performance. Here, scanning force microscopy (SFM) techniques become increasingly important. In addition to topographic information, various surface properties can be recorded on a nanometer length scale, such as electrical conductivity (conductive scanning force microscopy, C-SFM) and surface potential (Kelvin probe force microscopy, KPFM).rnrnIn the context of this work, the electrical SFM modes were applied to study the interplay be-tween morphology and electrical properties in hybrid optoelectronic structures, developed in the group of Prof. J. Gutmann (MPI-P Mainz). In particular, I investigated the working prin-ciple of a novel integrated electron blocking layer system. A structure of electrically conduct-ing pathways along crystalline TiO2 particles in an insulating matrix of a polymer derived ceramic was found and insulating defect structures could be identified. In order to get insights into the internal structure of a device I investigated a working hybrid solar cell by preparing a cross cut with focused ion beam polishing. With C-SFM, the functional layers could be identified and the charge transport properties of the novel active layer composite material could be studied. rnrnIn C-SFM, soft surfaces can be permanently damaged by (i) tip induced forces, (ii) high elec-tric fields and (iii) high current densities close to the SFM-tip. Thus, an alternative operation based on torsion mode topography imaging in combination with current mapping was intro-duced. In torsion mode, the SFM-tip vibrates laterally and in close proximity to the sample surface. Thus, an electrical contact between tip and sample can be established. In a series of reference experiments on standard surfaces, the working mechanism of scanning conductive torsion mode microscopy (SCTMM) was investigated. Moreover, I studied samples covered with free standing semiconducting polymer nano-pillars that were developed in the group of Dr. P. Theato (University Mainz). The application of SCTMM allowed non-destructive imag-ing of the flexible surface at high resolution while measuring the conductance on individual pillarsrnrnIn order to study light induced electrical effects on the level of single nanostructures, a new SFM setup was built. It is equipped with a laser sample illumination and placed in inert at-mosphere. With this photoelectric SFM, I investigated the light induced response in function-alized nanorods that were developed in the group of Prof. R. Zentel (University Mainz). A block-copolymer containing an anchor block and dye moiety and a semiconducting conju-gated polymer moiety was synthesized and covalently bound to ZnO nanorods. This system forms an electron donor/acceptor interface and can thus be seen as a model system of a solar cell on the nanoscale. With a KPFM study on the illuminated samples, the light induced charge separation between the nanorod and the polymeric corona could not only be visualized, but also quantified.rnrnThe results demonstrate that electrical scanning force microscopy can study fundamental processes in nanostructures and give invaluable feedback to the synthetic chemists for the optimization of functional nanomaterials.rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The understanding of the coupling between superconducting YBa2Cu3O7 (YBCO) layers decoupled by non superconducting PrBa2Cu3O7 (PBCO) layers in c-axis oriented superlattices was the aim of this thesis. For this purpose two conceptually different kind of transport experiments have been performed. rnrnIn the first type of transport experiments the current is flowing parallel to the layers. Here the coupling is probed indirectly using magnetic vortex lines, which are penetrating the superlattice. Movement of the vortex segments in neighbouring YBCO layers is more or less coherent depending on the thickness of both the superconducting and non superconducting layers. This in-plane transport was measured either by sending an external current through bridges patterned in the superlattice or by an induced internal current. rnThe vortex-creep activation energy U was determined by analysis of the in-plane resistive transition in an external magnetic field B oriented along the c-axis. The activation energies for two series of superlattices were investigated. In one series the thickness of the YBCO layers was constant (nY=4 unit cells) and the number of the PBCO unit cells was varied, while in the other the number of PBCO layers was constant (nP=4) and nY varied. The correlation length of the vortex system was determined to be 80 nm along the c-axis direction. It was found that even a single PBCO unit cell in a superlattice effectively cuts the flux lines into shorter weakly coupled segments, and the coupling of the vortex systems in neighbouring layers is negligible already for a thickness of four unit cells of the PBCO layers. A characteristic variation of the activation energy for the two series of superlattices was found, where U0 is proportional to the YBCO thickness. A change in the variation of U0 with the current I in the specimen was observed, which can be explained in terms of a crossover in the vortex creep process, generated by the transport current. At low I values the dislocations mediated (plastic) vortex creep leads to thermally assisted flux-flow behaviour, whereas at high current the dc transport measurements are dominated by elastic (collective) creep.rnThe analysis of standard dc magnetization relaxation data obtained for a series superlattices revealed the occurrence of a crossover from elastic (collective) vortex creep at low temperature to plastic vortex creep at high T. The crossover is generated by the T dependent macroscopic currents induced in the sample. The existence of this creep crossover suggests that, compared with the well known Maley technique, the use of the normalized vortex creep activation energy is a better solution for the determination of vortex creep parameters.rnrnThe second type of transport experiments was to measure directly a possible Josephson coupling between superconducting CuO2 double planes in the superlattices by investigation of the transport properties perpendicular to the superconducting planes. Here three different experiments have been performed. The first one was to pattern mesa structures photolithographically as in previous works. The second used three-dimensional nanostructures cut by a focused ion beam. For the these two experiments insufficient patterning capabilities prevented an observation of the Josephson effect in the current voltage curves. rnA third experiment used a-axis and (110) oriented YBCO films, where in-plane patterning can in principle be sufficient to measure transport perpendicular to the superconducting planes. Therefore the deposition of films with this unusual growth orientation was optimized and investigated. The structural and microstructural evolution of c-axis to a-axis orientation was monitored using x-ray diffraction, scanning electron microscopy and magnetization measurements. Films with full a-axis alignment parallel to the substrate normal could be achieved on (100)SrTiO3. Due to the symmetry of the substrate the c-axis direction in-plane is twofold. Transferring the deposition conditions to films grown on (110)SrTiO3 allowed the growth of (110) oriented YBCO films with a unique in-plane c-axis orientation. While these films were of high quality by crystallographic and macroscopic visual inspection, electron microscopy revealed a coherent crack pattern on a nanoscale. Therefore the actual current path in the sample was not determined by the macroscopic patterning which prohibited investigations of the in-plane anisotropy in this case.rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Um die in der Atmosphäre ablaufenden Prozesse besser verstehen zu können, ist es wichtig dort vorhandene Partikel gut charakterisieren zu können. Dazu gehört unter anderem die Bestimmung der chemischen Zusammensetzung der Partikel. Zur Analyse insbesondere organischer Partikel wurde dazu in einer früheren Promotion das Aerosol-Ionenfallen-Massenspektrometer (AIMS) entwickelt.Im Rahmen dieser Arbeit wurden Entwicklungsarbeiten durchgeführt, um die Charakteristiken des Prototypen zu verbessern sowie es für den Feldeinsatz tauglich zu machen. Die durchgeführten Veränderungen betreffen mechanische und elektrische Komponenten sowie das LabView Steuerungsprogramm. So wurde z.B. die Ionenquelle derart modifiziert, dass die Ionen nicht mehr permanent erzeugt werden, sondern nur innerhalb des Zeitraums wenn sie auch in der Ionenfalle gespeichert werden können. Durch diese Modifikation konnte das Signal-zu-Rausch Verhältnis deutlich verbessert werden. Nach Beendigung der Umbauten wurden in ausführlichen Laborstudien die einzelnen Instrumentenparameter detailliert charakterisiert. Neben den Spannungen die zur Fokussierung oder zur Speicherung der Ionen in der Ionenfalle dienen, wurden die unterschiedlichen Arten der resonanten Anregung, mittels der die Ionen in der Ionenfalle gezielt zu Schwingungen angeregt werden können, sehr genau untersucht. Durch eine gezielte Kombination der unterschiedlichen Arten der resonanten Anregung ist es möglich MSn-Studien durchzuführen. Nach erfolgreicher Charakterisierung konnte in weiteren Laborstudien die MSn-Fähigkeit des AIMS demonstriert werden. Für Tryptophan (C11H12N2O2) wurde anhand von MS4-Studien ausgehend von m/z 130 ein möglicher Fragmentierungsweg identifiziert. Für die einzelnen Stufen der MS4-Studien wurden die Nachweisgrenzen abgeschätzt. Im Rahmen der PARADE (PArticles and RAdicals: Diel observations of the impact of urban and biogenic Emissions) Messkampagne im August/September 2011 auf dem kleinen Feldberg in der Nähe von Frankfurt am Main wurde die Feldtauglichkeit des AIMS demonstriert. Die Nachweisgrenzen liegen für eine Mittelungszeit von 60 Minuten für Organik bei 1,4 µg m-3, für Nitrat bei 0,5 µg m-3 und für Sulfat bei 0,7 µg m-3, was ausreichend ist um atmosphärisches Aerosol messen zu können. Dies ist ein signifikanter Fortschritt im Vergleich zum Prototypen, der aufgrund schlechter Reproduzierbarkeit und Robustheit noch nicht feldtauglich war. Im Vergleich zum HR-ToF-AMS, einem Standard-Aerosolmassenspektrometer, zeigte sich, dass beide Instrumente vergleichbare Trends für die Spezies Nitrat, Sulfat und Organik messen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die Analyse optischer Spektren liefert einen kernmodellunabhängigen Zugang zur Bestimmung der Kernspins, Ladungsradien und elektromagnetischen Momente von Atomkernen im Grundzustand und von langlebigen Isomeren. Eine der vielseitigsten Methoden zur optischen Spektroskopie an kurzlebigen Isotopen ist die kollineare Laserspektroskopie. Im Rahmen dieser Arbeit wurde zum einen die TRIGA-LASER Strahlstrecke am Institut für Kernchemie der Universität Mainz durch die Implementierung einer neuen offline Oberflächenionenquelle für hohe Verdampfungstemperaturen und eines Strahlanalysesystems weiterentwickelt. Zum anderen wurde kollineare Laserspektroskopie an kurzlebigen Praseodym- und Cadmiumisotopen an ISOLDE/CERN durchgeführt. Die neue Ionenquelle ermöglichte dabei den Test der kollinearen Laserspektroskopie an Praseodymionen am TRIGA-LASER Experiment. Die Spektroskopie der Prasdeodymionen motivierte sich aus der Beobachtung einer zeitlichen Modulation der EC-Zerfallsrate von wasserstoffähnlichem 140Pr58+. Für die Erklärung dieser sogenannten GSI Oszillationen wird unter anderem das magnetische Moment des Kerns benötigt, welches bislang noch nicht experimentell bestimmt wurde. Zudem wurde für wasserstoffähnliches 140Pr58+ überraschenderweise eine kleinere EC-Zerfallskonstante gemessen als für heliumähnliches 140Pr57+. Die Erklärung dieses Phänomens setzt ein positives magnetisches Moment voraus. Bei der Spektroskopie am COLLAPS Experiment wurden erstmals die magnetischen Momente von 135Pr, 136Pr und 137Pr vermessen. Aufgrund zu geringer Produktionsraten war die Spektroskopie des gewünschten Isotops 140Pr jedoch nicht erfolgreich. Die Untersuchung der Cadmiumisotope ist kernphysikalisch motiviert. In der Zinnregion erstrecken sich die Isotope über die beiden magischen Zahlen N=50 und N=82 bei gleichzeitiger Nähe des Z=50 Schalenabschlusses. Hier können verschiedene Kernmodelle getestet werden, die sich beispielsweise hinsichtlich der Stärke des N=82 Schalenabschlusses widersprechen. Diese Arbeit berichtet über erste Ergebnisse der Spektroskopie an Cadmiumatomen, die sich über die Isotope 106−124,126Cd sowie die zugehörigen langlebigen I=11/2− Isomere erstreckt. Die zuvor experimentell bekannten oder aus dem erweiterten Schalenmodell abgeleiteten Kernspins konnten für alle Isotope bis auf 119Cd bestätigt werden. Der Kernspin von 119Cd wurde eindeutig zu I=1/2 bestimmt. Die elektrischen Quadrupolmomente der Isomere zeigen ein bemerkenswert lineares Verhalten in Abhängigkeit von der Neutronenzahl und dies über die eigentliche Kapazität der 1h11/2 Unterschale hinaus. Die Änderungen der mittleren quadratischen Ladungsradien zeigen den auch an Indium- und Zinnisotopen beobachteten stetigen Verlauf. Der lineare Anteil passt sehr gut zu den Berechnung des Tröpfchenmodells in der Parametrisierung nach Berchidevsky und Tondeur. Die Differenzen der mittleren quadratischen Ladungsradien zwischen Grund- und isomeren Zustand der ungeraden Cadmiumisotope zeigen einen interessanten parabolischen Verlauf mit einem Minimum zwischen A=117 und A=119.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die Funktionsweise der Laserionenquellenfalle LIST, sowie deren Implementierung bei der Forschungseinrichtung ISOLDE am CERN als neue Standard-Ionenquelle und die ermittelten Spezifikationen Effizienz und Selektivität werden vorgestellt.rnrnDurch die Implementierung der LIST bei ISOLDE konnte on-line mit Hilfe von Radionukliden ein Minimalwert zur Unterdrückung von Kontaminationen durch die LIST bestimmt werden. Die erfolgreiche Unterdrückung von Francium-Kontamination ermöglichte es, neue Messdaten für den mittleren Ladungsradius und die Hyperfeinstruktur für Po-217 zu erzeugen.rnrnUm die Funktionalität der LIST bei ISOLDE hinsichtlich der Ionisationseffizienz gegenüber anderen Ionenquellen einzuordnen, wurden in Mainz am RISIKO-Massenseparator mit der bereits existierenden Standard-Ionenquelle RILIS und der LIST die Effizienzen bestimmt und miteinander verglichen. Es konnte gezeigt werden, dass die LIST im Modus hoher Ionisationseffizienz eine vergleichbare Effizienz aufweist wie die RILIS. Im Modus zur Produktion eines hochreinen Ionenstrahls ist die Ionisationseffizienz gegenüber der RILIS reduziert.rnrnDa die Bestimmung der Selektivität im On-line-Betrieb aufwendig und zeitintensiv ist, wurde die Reinheit des Ionenstrahls am RISIKO-Massenseparator mittels Laufzeitmessungen der Ionen off-line bestimmt und analysiert. Die Zeitstrukturen der RILIS ermöglichen einerseits Rückschlüsse auf die Reinheit des Ionenstrahls zu ziehen, andererseits konnte auch die Ionisation außerhalb des Atomisators, in dem überwiegend die resonante Ionisation stattfindet, nachgewiesen werden. Durch diesen Nachweis kann der Effizienzverlust während der Produktion eines hochreinen Ionenstrahls erklärt werden. Zudem bietet er einen Ansatz für weitere Entwicklungsarbeiten der LIST zur Steigerung der Effizienz.rnrnEine Übertragung der Messergebnisse zur Zeitstruktur der RILIS auf die LIST eröffnet neue Möglichkeiten zur Steigerung deren Selektivität im massenselektiven Mode. Dieser wurde anhand von Simulationen überprüft und mit Messungen an Kalium experimentell quantifiziert.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work investigates the influence of chemical reactions on the release of elements from target-ion source units for ISOL facilities. Methods employed are thermochromatography, yield and hold-up time measurements; adsorption enthalpies have been determined for Ag and In. The results obtained with these methods are consistent. Elements exhibit reversible or irreversible reactions on different surfaces (Tantalum, quartz, sapphire). The interactions with surfaces inside the target-ion source unit can be used to improve the quality of radioactive ion beams. Spectroscopic data obtained at CERN-ISOLDE using a medium-temperature quartz transfer line show the effectivity of selective adsorption for beam purification. New gamma lines of 131Cd have been observed and a tentative decay scheme is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die Elektronen in wasserstoff- und lithium-ähnlichen schweren Ionen sind den extrem starken elektrischen und magnetischen Feldern in der Umgebung des Kerns ausgesetzt. Die Laserspektroskopie der Hyperfeinaufspaltung im Grundzustand des Ions erlaubt daher einen sensitiven Test der Quantenelektrodynamik in starken Feldern insbesondere im magnetischen Sektor. Frühere Messungen an wasserstoffähnlichen Systemen die an einer Elektronenstrahl-Ionenfalle (EBIT) und am Experimentierspeicherring (ESR) der GSI Darmstadt durchgeführt wurden, waren in ihrer Genauigkeit durch zu geringe Statistik, einer starken Dopplerverbreiterung und der großen Unsicherheit in der Ionenenergie limitiert. Das ganze Potential des QED-Tests kann nur dann ausgeschöpft werden, wenn es gelingt sowohl wasserstoff- als auch lithium-ähnliche schwere Ionen mit einer um 2-3 Größenordnung gesteigerten Genauigkeit zu spektroskopieren. Um dies zu erreichen, wird gegenwärtig das neue Penningfallensystem SPECTRAP an der GSI aufgebaut und in Betrieb genommen. Es ist speziell für die Laserspektroskopie an gespeicherten hochgeladenen Ionen optimiert und wird in Zukunft von HITRAP mit nierderenergetischen hochgeladenen Ionen versorgt werden.rnrnSPECTRAP ist eine zylindrische Penningfalle mit axialem Zugang für die Injektion von Ionen und die Einkopplung eines Laserstrahls sowie einem radialen optischen Zugang für die Detektion der Fluoreszenz. Um letzteres zu realisieren ist der supraleitende Magnet als Helmholtz-Spulenpaar ausgelegt. Um die gewünschte Genauigkeit bei der Laserspektroskopie zu erreichen, muss ein effizienter und schneller Kühlprozess für die injizierten hochegeladenen Ionen realisiert werden. Dies kann mittels sympathetischer Kühlung in einer lasergekühlten Wolke leichter Ionen realisiert werden. Im Rahmen dieser Arbeit wurde ein Lasersystem und eine Ionenquelle für die Produktion einer solchen 24Mg+ Ionenwolke aufgebaut und erfolgreich an SPECTRAP in Betrieb genommen. Dazu wurde ein Festkörperlasersystem für die Erzeugung von Licht bei 279.6 nm entworfen und aufgebaut. Es besteht aus einem Faserlaser bei 1118 nm der in zwei aufeinanderfolgenden Frequenzverdopplungsstufen frequenzvervierfacht wird. Die Verdopplerstufen sind als aktiv stabilisierte Resonantoren mit nichtlinearen Kristallen ausgelegt. Das Lasersystem liefert unter optimalen Bedingeungen bis zu 15 mW bei der ultravioletten Wellenlänge und erwies sich während der Teststrahlzeiten an SPECTRAP als ausgesprochen zuverlässig. Desweiteren wurde eine Ionequelle für die gepulste Injektion von Mg+ Ionen in die SPECTRAP Falle entwickelt. Diese basiert auf der Elektronenstoßionisation eines thermischen Mg-Atomstrahls und liefert in der gepulsten Extraktion Ionenbündel mit einer kleinen Impuls- und Energieverteilung. Unter Nutzung des Lasersystems konnten damit an SPECTRAP erstmals Ionenwolken mit bis zu 2600 lasergekühlten Mg Ionen erzeugt werden. Der Nachweis erfolgte sowohl mittels Fluoreszenz als auch mit der FFT-ICR Technik. Aus der Analyse des Fluoreszenz-Linienprofils lässt sich sowohl die Sensitivität auf einzelne gespeicherte Ionen als auch eine erreichte Endtemperatur in der Größenordnung von ≈ 100 mK nach wenigen Sekunden Kühlzeit belegen.