4 resultados para environmental concentrations
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
For the safety assessments of nuclear waste repositories, the possible migration of the radiotoxic waste into environment must be considered. Since plutonium is the major contribution at the radiotoxicity of spent nuclear waste, it requires special care with respect to its mobilization into the groundwater. Plutonium has one of the most complicated chemistry of all elements. It can coexist in 4 oxidation states parallel in one solution. In this work is shown that in the presence of humic substances it is reduced to the Pu(III) and Pu(IV). This work has the focus on the interaction of Pu(III) with natural occurring compounds (humic substances and clay minerals bzw. Kaolinite), while Pu(IV) was studied in a parallel doctoral work by Banik (in preparation). As plutonium is expected under extreme low concentrations in the environment, very sensitive methods are needed to monitor its presence and for its speciation. Resonance ionization mass spectrometry (RIMS), was used for determining the concentration of Pu in environmental samples, with a detection limit of 106- 107 atoms. For the speciation of plutonium CE-ICP-MS was routinely used to monitor the behaviour of Pu in the presence of humic substances. In order to reduce the detection limits of the speciation methods, the coupling of CE to RIMS was proposed. The first steps have shown that this can be a powerful tool for studies of pu under environmental conditions. Further, the first steps in the coupling of two parallel working detectors (DAD and ICP_MS ) to CE was performed, for the enabling a precise study of the complexation constants of plutonium with humic substances. The redox stabilization of Pu(III) was studied and it was determined that NH2OHHCl can maintain Pu(III) in the reduced form up to pH 5.5 – 6. The complexation constants of Pu(III) with Aldrich humic acid (AHA) were determined at pH 3 and 4. the logß = 6.2 – 6.8 found for these experiments was comparable with the literature. The sorption of Pu(III) onto kaolinite was studied in batch experiments and it was determine dthat the pH edge was at pH ~ 5.5. The speciation of plutonium on the surface of kaolinite was studied by EXAFS/XANES. It was determined that the sorbed species was Pu(IV). The influence of AHA on the sorption of Pu(III) onto kaolinite was also investigated. It was determined that at pH < 5 the adsorption is enhanced by the presence of AHA (25 mg/L), while at pH > 6 the adsorption is strongly impaired (depending also on the adding sequence of the components), leading to a mobilization of plutonium in solution.
Resumo:
Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.
Resumo:
Plutonium represents the major contribution to the radiotoxicity of spent nuclear fuel over storage times of up to several hundred thousand years. The speciation of plutonium in aquifer systems is important in order to assess the risks of high-level nuclear waste disposal and to acquire a deep knowledge of the mobilization and immobilization behavior of plutonium. In aqueous solutions, plutonium can coexist in four oxidation states and each one of them has different chemical and physical behavior. Tetravalent plutonium is the most abundant under natural conditions. Therefore, detailed speciation studies of tetravalent plutonium in contact with humic substances (HS) and kaolinite as a model clay mineral have been performed in this work. Plutonium is present in the environment at an ultratrace level. Therefore, speciation of Pu at the ultratrace level is mandatory. Capillary electrophoresis (CE) coupled to resonance ionization mass spectrometry (RIMS) was used as a new speciation method. CE-RIMS enables to improve the detection limit for plutonium species by 2 to 3 orders of magnitude compared to the previously developed CE-ICP-MS. For understanding the behavior of Pu(IV) in aqueous systems, redox reactions, complexation, and sorption behavior of plutonium were studied. The redox behavior of plutonium in contact with humic acid (HA) and fulvic acid (FA) was investigated. A relatively fast reduction of Pu(VI) in contact with HS was observed. It was mainly reduced to Pu(IV) and Pu(III) within a couple of weeks. The time dependence of the Pu(IV) complexation with Aldrich HA was investigated and a complex constant (logßLC) between 6.4 - 8.4 of Pu(IV) was determined by means of ultrafiltration taking into account the loading capacity (LC). The sorption of tetravalent plutonium onto kaolinite was investigated as a function of pH in batch experiments under aerobic and anaerobic conditions. The sorption edge was found at about pH = 1 and a maximum sorption at around pH = 8.5. In the presence of CO2 at pH > 8.5, the sorption of plutonium was decreased probably due to the formation of soluble carbonate complexes. For comparison, the sorption of Th(IV) onto kaolinite was also investigated and consistent results were found. The Pu(IV) sorption onto kaolinite was studied by XANES and EXAFS at pH 1, 4, 9 and the sorbed species on kaolinite surface was Pu(IV). Depending on the pH, only 1 - 10 % of the sorbed plutonium is desorbed from kaolinite and released into a fresh solution at the same pH value. Furthermore, the sorption of HS onto kaolinite was studied as a function of pH at varying concentrations of HS, as a prerequisite to understand the more complex ternary system. The sorption of HA onto kaolinite was found to be higher than that of FA. The investigation of the ternary systems (plutonium-kaolinite-humic substances) is performed as a function of pH, concentration of HS, and the sequences of adding the reactants. The presence of HS strongly influences the sorption of Pu(IV) onto kaolinite over the entire pH range. For comparison, the influence of HS on the sorption of Th(IV) onto kaolinite was also investigated and a good agreement with the results of Pu(IV) was obtained.
Resumo:
ABSTRACT One of the major ecological challenges on Lake Victoria resources is the existence of “hot spots”, caused by human waste, urban runoff, and industrial effluents. The lake is tending towards eutrophication which is attributed to the increasing human population in its watershed. A report of the levels of perfluorooctane sulfonate and perfluorooctanoic acid in environmental matrices of Lake Victoria is presented, and the management implication of perfluorinated compounds and similar potential organic pollutants examined. Two widely consumed and economically important fish species namely Lates niloticus (Nile perch) and Oreochromis niloticus (Nile tilapia) were obtained from Winam gulf of Lake Victoria, Kenya, and analysed for perfluorooctane sulfonate and perfluorooctanoic acid in muscles and liver using liquid chromatography coupled with mass spectroscopy. Variability in the concentrations of perfluorooctanoic acid or perfluorooctane sulfonate in river waters (range perfluorooctanoic acid 0.4 – 96.4 ng/L and perfluorooctane sulfonate < 0.4 – 13.2 ng/L) was higher than for Lake waters (range perfluorooctanoic acid 0.4 – 11.7 ng/L and perfluorooctane sulfonate < 0.4 – 2.5 ng/L respectively). Significant correlations were tested between perfluorinated compounds levels in sediments, fish and water. Wastewater treatment plants and other anthropogenic sources have been identified as significant sources or pathways for the introduction of perfluoroalkyl compounds into Lake Victoria ecosystem. In this study, elevated concentrations of perfluorooctanoic acid and perfluorooctane sulfonate was found in two wastewater treatment plants (WWTPs) in Kisumu, City of Kenya. An alternative analytical method to liquid chromatography/ mass spectroscopy for analysis of perfluorocarboxylic acids in abiotic and biotic matrices where high concentrations are expected is also presented. Derivatisation of the acid group to form a suitable alkyl ester provided a suitable compound for mass spectroscopy detection coupled to gas chromatography instrumental analysis. The acid is esterified by an alkyl halide i.e benzyl bromide as the alkylating agent for Perfluorocarboxylic acids quantification. The study also involved degradability measurements of emerging perfluorinated surfactants substitutes. The stability of the substitutes of perfluorinated surfactants was tested by employing advanced oxidation processes, followed by conventional tests, among them an automated method based on the manometric respirometry test and standardized fix bed bioreactor [FBBR] on perfluorobutane sulfonate (PFBS), a fluoroethylene polymer, fluorosurfactant (Zonyl), two fluoraliphaticesters (NOVEC ™ FC4430 and NOVEC ™ FC4432) and 10-(trifluoromethoxy) decane-sulfonate. Most of these emmerging surfactants are well-established in the market and have been used in several applications as alternatives to PFOS and PFOA based surfactants. The results of this study can be used as pioneer information for further studies on the sources, behaviour and fate of PFOA and PFOS and other related compounds in both abiotic and biota compartments of Lake Victoria and other lakes. Further an overview in degradation of emerging perfluorinated compounds substitutes is presented. Contribution in method development especially for acid group based fluorosurfactants is presented. The data obtained in this study can particularly be considered when formulating policies and management measures for preservation and sustainability of Lake Victoria resources.