2 resultados para environmental chemical

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plutonium represents the major contribution to the radiotoxicity of spent nuclear fuel over storage times of up to several hundred thousand years. The speciation of plutonium in aquifer systems is important in order to assess the risks of high-level nuclear waste disposal and to acquire a deep knowledge of the mobilization and immobilization behavior of plutonium. In aqueous solutions, plutonium can coexist in four oxidation states and each one of them has different chemical and physical behavior. Tetravalent plutonium is the most abundant under natural conditions. Therefore, detailed speciation studies of tetravalent plutonium in contact with humic substances (HS) and kaolinite as a model clay mineral have been performed in this work. Plutonium is present in the environment at an ultratrace level. Therefore, speciation of Pu at the ultratrace level is mandatory. Capillary electrophoresis (CE) coupled to resonance ionization mass spectrometry (RIMS) was used as a new speciation method. CE-RIMS enables to improve the detection limit for plutonium species by 2 to 3 orders of magnitude compared to the previously developed CE-ICP-MS. For understanding the behavior of Pu(IV) in aqueous systems, redox reactions, complexation, and sorption behavior of plutonium were studied. The redox behavior of plutonium in contact with humic acid (HA) and fulvic acid (FA) was investigated. A relatively fast reduction of Pu(VI) in contact with HS was observed. It was mainly reduced to Pu(IV) and Pu(III) within a couple of weeks. The time dependence of the Pu(IV) complexation with Aldrich HA was investigated and a complex constant (logßLC) between 6.4 - 8.4 of Pu(IV) was determined by means of ultrafiltration taking into account the loading capacity (LC). The sorption of tetravalent plutonium onto kaolinite was investigated as a function of pH in batch experiments under aerobic and anaerobic conditions. The sorption edge was found at about pH = 1 and a maximum sorption at around pH = 8.5. In the presence of CO2 at pH > 8.5, the sorption of plutonium was decreased probably due to the formation of soluble carbonate complexes. For comparison, the sorption of Th(IV) onto kaolinite was also investigated and consistent results were found. The Pu(IV) sorption onto kaolinite was studied by XANES and EXAFS at pH 1, 4, 9 and the sorbed species on kaolinite surface was Pu(IV). Depending on the pH, only 1 - 10 % of the sorbed plutonium is desorbed from kaolinite and released into a fresh solution at the same pH value. Furthermore, the sorption of HS onto kaolinite was studied as a function of pH at varying concentrations of HS, as a prerequisite to understand the more complex ternary system. The sorption of HA onto kaolinite was found to be higher than that of FA. The investigation of the ternary systems (plutonium-kaolinite-humic substances) is performed as a function of pH, concentration of HS, and the sequences of adding the reactants. The presence of HS strongly influences the sorption of Pu(IV) onto kaolinite over the entire pH range. For comparison, the influence of HS on the sorption of Th(IV) onto kaolinite was also investigated and a good agreement with the results of Pu(IV) was obtained.