2 resultados para borehole carbon correction factor (avogadro units)

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray laser fluorescence spectroscopy of the 2s-2p transition in Li-like ions is promising to become a widely applicable tool to provide information on the nuclear charge radii of stable and radioactive isotopes. For performing such experiments at the Experimental Storage Ring ESR, and the future NESR within the FAIR Project, a grazing incidence pumped (GRIP) x-ray laser (XRL) was set up at GSI Darmstadt using PHELIX (Petawatt High Energy Laser for heavy Ions eXperiments). The experiments demonstrated that lasing using the GRIP geometry could be achieved with relatively low pump energy, a prerequisite for higher repetition rate. In the first chapter the need of a plasma XRL is motivated and a short history of the plasma XRL is presented. The distinctive characteristic of the GRIP method is the controlled deposition of the pump laser energy into the desired plasma density region. While up to now the analysis performed were mostly concerned with the plasma density at the turning point of the main pump pulse, in this thesis it is demonstrated that also the energy deposition is significantly modified for the GRIP method, being sensitive in different ways to a large number of parameters. In the second chapter, the theoretical description of the plasma evolution, active medium and XRL emission properties are reviewed. In addition an innovative analysis of the laser absorption in plasma which includes an inverse Bremsstrahlung (IB) correction factor is presented. The third chapter gives an overview of the experimental set-up and diagnostics, providing an analytical formula for the average and instantaneous traveling wave speed generated with a tilted, on-axis spherical mirror, the only focusing system used up to now in GRIP XRL. The fourth chapter describes the experimental optimization and results. The emphasis is on the effect of the incidence angle of the main pump pulse on the absorption in plasma and on output and gain in different lasing lines. This is compared to the theoretical results for two different incidence angles. Significant corrections for the temperature evolution during the main pump pulse due to the incidence angle are demonstrated in comparison to a simple analytical model which does not take into account the pumping geometry. A much better agreement is reached by the model developed in this thesis. An interesting result is also the appearance of a central dip in the spatially resolved keV emission which was observed in the XRL experiments for the first time and correlates well with previous near field imaging and plasma density profile measurements. In the conclusion also an outlook to the generation of shorter wavelength XRL’s is given.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Zusammenfassung:Die Quartärstruktur des respiratorischen Proteins Hämocyanin (Isoform HtH1) aus der marinen Schnecke Haliotis tuberculata wurde vermittels Kryoelektronen-mikroskopie und 3D-Rekonstruktion untersucht. Das Molekül ist zylinderförmig, hat einen Durchmesser von ca. 35 nm und besteht aus einer Zylinderwand und einem internen Kragenkomplex. Dieser wiederum besteht aus einem Collar und einem Arc.Die kryoelektronenmikroskopischen Aufnahmen von in glasartigem Eis fixierten HtH1-Molekülen brachte eine enorme Verbesserung der Anzahl der zur Verfügung stehenden Ansichtswinkel gegenüber den negativkontrastierten Molekülen, die auf Karbonfilm präpariert waren.Die 3D-Rekonstruktion des HtH1 mittels Aufnahmen bei drei verschiedenen Defo-kuswerten verbesserte die Auflösung noch einmal deutlich gegenüber den Rekon-struktionen, die aus Aufnahmen bei einem festen Defokuswert gemacht wurden, und zwar auf 12 Å. Das Molekül besitzt eine D5-Symmetrie.Aus dieser bisher genausten Rekonstruktion eines Molluskenhämocyanins aus EM-Bildern ließen sich folgende neue Strukturdetails ableiten:· Ein Untereinheitendimer konnte als Repeating Unit im Dekamer des HtH1 beschrieben werden.· Das Untereinheitendimer konnte aus der 3D-Dichtekarte isoliert werden. Es be-steht eindeutig aus 16 Massen, die funktionellen Domänen entsprechen. Zwei dieser Massen bilden den Collar, zwei den Arc und 12 das Wandsegment.· Die gegenläufige Anordnung der beiden Untereinheiten innerhalb dieses Unte-reinheitendimers konnten bestätigt und auf zwei Möglichkeiten eingeschränkt werden.· Die Zahl der alternativen Anordnungen der 16 funktionellen Domänen (HtH1-a bis HtH1-h) im Untereinheitendimer konnten von 80 auf 2 eingeengt werden.· Es konnte über molekulares Modellieren mithilfe einer publizierten Kristallstruk-tur eine 3D-Struktur fastatomarer Auflösung der funktionellen Domäne HtH1-g berechnet werden.· Die funktionelle Domäne HtH1-g konnte als Domänenpaar plausibel in die 3D?Dichtekarte des Untereinheitendimers eingepasst werden, und zwar in die beiden Massen des Arc.Aus der elektronenmikroskopisch gewonnenen Dichtekarte wurde mit Hilfe des