2 resultados para Water development project

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The subject of this thesis is the development of a Gaschromatography (GC) system for non-methane hydrocarbons (NMHCs) and measurement of samples within the project CARIBIC (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container, www.caribic-atmospheric.com). Air samples collected at cruising altitude from the upper troposphere and lowermost stratosphere contain hydrocarbons at low levels (ppt range), which imposes substantial demands on detection limits. Full automation enabled to maintain constant conditions during the sample processing and analyses. Additionally, automation allows overnight operation thus saving time. A gas chromatography using flame ionization detection (FID) together with the dual column approach enables simultaneous detection with almost equal carbon atom response for all hydrocarbons except for ethyne. The first part of this thesis presents the technical descriptions of individual parts of the analytical system. Apart from the sample treatment and calibration procedures, the sample collector is described. The second part deals with analytical performance of the GC system by discussing tests that had been made. Finally, results for measurement flight are assessed in terms of quality of the data and two flights are discussed in detail. Analytical performance is characterized using detection limits for each compound, using uncertainties for each compound, using tests of calibration mixture conditioning and carbon dioxide trap to find out their influence on analyses, and finally by comparing the responses of calibrated substances during period when analyses of the flights were made. Comparison of both systems shows good agreement. However, because of insufficient capacity of the CO2 trap the signal of one column was suppressed due to breakthroughed carbon dioxide so much that its results appeared to be unreliable. Plausibility tests for the internal consistency of the given data sets are based on common patterns exhibited by tropospheric NMHCs. All tests show that samples from the first flights do not comply with the expected pattern. Additionally, detected alkene artefacts suggest potential problems with storing or contamination within all measurement flights. Two last flights # 130-133 and # 166-169 comply with the tests therefore their detailed analysis is made. Samples were analyzed in terms of their origin (troposphere vs. stratosphere, backward trajectories), their aging (NMHCs ratios) and detected plumes were compared to chemical signatures of Asian outflows. In the last chapter a future development of the presented system with focus on separation is drawn. An extensive appendix documents all important aspects of the dissertation from theoretical introduction through illustration of sample treatment to overview diagrams for the measured flights.