5 resultados para Surface relief grating
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn
Vergleichende computergestützte funktionsmorphologische Analyse an Molaren cercopithecoider Primaten
Resumo:
Die Analyse funktioneller Zusammenhänge zwischen Ernährung und Zahnmorphologie ist ein wichtiger Aspekt primatologischer und paläontologischer Forschung. Als überdauernder Teil des Verdauungssystems geben Zähne die bestmöglichen Hinweise auf die Ernährungsstrategien (ausgestorbener) Arten und eine Fülle weiterer Informationen. Aufgrund dessen ist es für die wissenschaftliche Arbeit von größter Bedeutung, die Zähne so detailliert und exakt wie möglich in ihrer gesamten Struktur zu erfassen. Bisher wurden zumeist zweidimensionale Parameter verwendet, um die komplexe Kronenmorphologie von Primatenmolaren vergleichend zu untersuchen. Die vorliegende Arbeit hatte das Ziel, Zähne verschiedener Arten von Altweltaffen mittels computerbasierter Methoden dreidimensional zu erfassen und neue Parameter zu definieren, mit denen die Form dieser Zähne objektiv erfasst und funktionell interpretiert werden kann. Mit einem Oberflächen-Scanner wurden die Gebisse einer Stichprobe von insgesamt 48 Primaten von fünf verschiedenen Arten eingescannt und mit Bildverarbeitungsmethoden so bearbeitet, dass dreidimensionale digitale Modelle einzelner Backenzähne zur Analyse vorlagen. Es wurden dabei sowohl Arten ausgewählt, die eine für ihre Gattung typische Ernährungsweise besitzen - also Frugivorie bei den Cercopithecinen und Folivorie bei den Colobinen - als auch solche, die eine davon abweichende Alimentation bevorzugen. Alle Altweltaffen haben sehr ähnliche Molaren. Colobinen haben jedoch höhere und spitzere Zahnhöcker, dünneren Zahnschmelz und scheinen ihre Zähne weniger stark abzukauen als die Meerkatzen. Diese Beobachtungen konnten mit Hilfe der neuen Parameter quantifiziert werden. Aus der 3D-Oberfläche und der Grundfläche der Zähne wurde ein Index gebildet, der die Stärke des Oberflächenreliefs angibt. Dieser Index hat bei Colobinen deutlich höhere Werte als bei Cercopithecinen, auch bei Zähnen, die schon stark abgekaut sind. Die Steilheit der Höcker und ihre Ausrichtung wurden außerdem gemessen. Auch diese Winkelmessungen bestätigten das Bild. Je höher der Blätteranteil an der Ernährung ist, desto höher sind die Indexwerte und umso steiler sind die Höcker. Besonders wichtig war es, dies auch für abgekaute Zähne zu bestätigen, die bisher nicht in funktionelle Analysen miteinbezogen wurden. Die Ausrichtung der Höckerseiten gibt Hinweise auf die Kaubewegung, die zum effizienten Zerkleinern der Nahrung notwendig ist. Die Ausrichtung der Höcker der Colobinen deutet darauf hin, dass diese Primaten flache, gleitende Kaubewegungen machen, bei denen die hohen Höcker aneinander vorbei scheren. Dies ist sinnvoll zum Zerschneiden von faserreicher Nahrung wie Blättern. Cercopithecinen scheinen ihre Backenzähne eher wie Mörser und Stößel zu verwenden, um Früchte und Samen zu zerquetschen und zu zermahlen. Je nachdem, was neben der hauptsächlichen Nahrung noch gekaut wird, unterscheiden sich die Arten graduell. Anders als bisher vermutet wurde, konnte gezeigt werden, dass Colobinen trotz des dünnen Zahnschmelzes ihre Zähne weniger stark abkauen und weniger Dentin freigelegt wird. Dies gibt eindeutige Hinweise auf die Unterschiede in der mechanischen Belastung, die während des Kauvorgangs auf die Zähne wirkt, und lässt sich gut mit der Ernährung der Arten in Zusammenhang bringen. Anhand dieser modellhaften Beobachtungen können in Zukunft ausgestorbene Arten hinsichtlich ihrer Ernährungsweise mit 3D-Techniken untersucht werden.
Resumo:
Over the last three decades, sensors based on the phenomenon of surface plasmon resonance have proven particularly suitable for real time thin film characterization, gas detection, biomolecular interaction examination and to supplement electrochemical methods. Systems based on prism coupling have been combined with fluorescence detection under the name of surface plasmon fluorescence spectroscopy to increase sensitivity even further. Alternatively, metal gratings can be employed to match photons for plasmon resonance. The real time monitoring of binding reactions not yet been reported in the combination of fluorescence detection and grating coupling. Grating-based systems promise more competitive products, because of reduced operating costs, and offer benefits for device engineering. This thesis is comprised of a comprehensive study of the suitability of grating coupling for fluorescence based analyte detection. Fundamental properties of grating coupled surface plasmon fluorescence spectroscopy are described, as well as issues related to the commercial realization of the method. Several new experimental techniques are introduced and demonstrated in order to optimize performance in certain areas and improve upon capabilities in respect to prism-based systems. Holographically fabricated gratings are characterized by atomic force microscopy and optical methods, aided by simulations and profile parameters responsible for efficient coupling are analyzed. The directional emission of fluorophores immobilized on a grating surface is studied in detail, including the magnitude and geometry of the fluorescence emission pattern for different grating constants and polarizations. Additionally, the separation between the minimum of the reflected intensity and the maximum fluorescence excitation position is examined. One of the key requirements for the commercial feasibility of grating coupling is the cheap and faithful mass production of disposable samples from a given master grating. The replication of gratings is demonstrated by a simple hot embossing method with good reproducibility to address this matter. The in-situ fluorescence detection of analyte immobilization and affinity measurements using grating coupling are described for the first time. The physical factors related to the sensitivity of the technique are assessed and the lower limit of detection of the technique is determined for an exemplary assay. Particular attention is paid to the contribution of bulk fluorophores to the total signal in terms of magnitude and polarization of incident and emitted light. Emission from the bulk can be a limiting factor for experiments with certain assay formats. For that reason, a novel optical method, based on the modulation of both polarization and intensity of the incident beam, is introduced and demonstrated to be capable of eliminating this contribution.
Resumo:
CONCLUSIONS The focus of this work was the investigation ofanomalies in Tg and dynamics at polymer surfaces. Thethermally induced decay of hot-embossed polymer gratings isstudied using laser-diffraction and atomic force microscopy(AFM). Monodisperse PMMA and PS are selected in the Mwranges of 4.2 to 65.0 kg/mol and 3.47 to 65.0 kg/mol,respectively. Two different modes of measurement were used:the one mode uses temperature ramps to obtain an estimate ofthe near-surface glass temperature, Tdec,0; the other modeinvestigates the dynamics at a constant temperature aboveTg. The temperature-ramp experiments reveal Tdec,0 valuesvery close to the Tg,bulk values, as determined bydifferential scanning calorimetry (DSC). The PMMA of65.0 kg/mol shows a decreased value of Tg, while the PS samples of 3.47 and 10.3 kg/mol (Mw
Resumo:
Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn