7 resultados para Surface diffusion

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis, we investigated the evaporation of sessile microdroplets on different solid substrates. Three major aspects were studied: the influence of surface hydrophilicity and heterogeneity on the evaporation dynamics for an insoluble solid substrate, the influence of external process parameters and intrinsic material properties on microstructuring of soluble polymer substrates and the influence of an increased area to volume ratio in a microfluidic capillary, when evaporation is hindered. In the first part, the evaporation dynamics of pure sessile water drops on smooth self-assembled monolayers (SAMs) of thiols or disulfides on gold on mica was studied. With increasing surface hydrophilicity the drop stayed pinned longer. Thus, the total evaporation time of a given initial drop volume was shorter, since the drop surface, through which the evaporation occurs, stays longer large. Usually, for a single drop the volume decreased linearly with t1.5, t being the evaporation time, for a diffusion-controlled evaporation process. However, when we measured the total evaporation time, ttot, for multiple droplets with different initial volumes, V0, we found a scaling of the form V0 = attotb. The more hydrophilic the substrate was, the more showed the scaling exponent a tendency to an increased value up to 1.6. This can be attributed to an increasing evaporation rate through a thin water layer in the vicinity of the drop. Under the assumption of a constant temperature at the substrate surface a cooling of the droplet and thus a decreased evaporation rate could be excluded as a reason for the different scaling exponent by simulations performed by F. Schönfeld at the IMM, Mainz. In contrast, for a hairy surface, made of dialkyldisulfide SAMs with different chain lengths and a 1:1 mixture of hydrophilic and hydrophobic end groups (hydroxy versus methyl group), the scaling exponent was found to be ~ 1.4. It increased to ~ 1.5 with increasing hydrophilicity. A reason for this observation can only be speculated: in the case of longer hydrophobic alkyl chains the formation of an air layer between substrate and surface might be favorable. Thus, the heat transport to the substrate might be reduced, leading to a stronger cooling and thus decreased evaporation rate. In the second part, the microstructuring of polystyrene surfaces by drops of toluene, a good solvent, was investigated. For this a novel deposition technique was developed, with which the drop can be deposited with a syringe. The polymer substrate is lying on a motorized table, which picks up the pendant drop by an upward motion until a liquid bridge is formed. A consecutive downward motion of the table after a variable delay, i.e. the contact time between drop and polymer, leads to the deposition of the droplet, which can evaporate. The resulting microstructure is investigated in dependence of the processes parameters, i.e. the approach and the retraction speed of the substrate and the delay between them, and in dependence of the intrinsic material properties, i.e. the molar mass and the type of the polymer/solvent system. The principal equivalence with the microstructuring by the ink-jet technique was demonstrated. For a high approach and retraction speed of 9 mm/s and no delay between them, a concave microtopology was observed. In agreement with the literature, this can be explained by a flow of solvent and the dissolved polymer to the rim of the pinned droplet, where polymer is accumulated. This effect is analogue to the well-known formation of ring-like stains after the evaporation of coffee drops (coffee-stain effect). With decreasing retraction speed down to 10 µm/s the resulting surface topology changes from concave to convex. This can be explained with the increasing dissolution of polymer into the solvent drop prior to the evaporation. If the polymer concentration is high enough, gelation occurs instead of a flow to the rim and the shape of the convex droplet is received. With increasing delay time from below 0 ms to 1s the depth of the concave microwells decreases from 4.6 µm to 3.2 µm. However, a convex surface topology could not be obtained, since for longer delay times the polymer sticks to the tip of the syringe. Thus, by changing the delay time a fine-tuning of the concave structure is accomplished, while by changing the retraction speed a principal change of the microtopolgy can be achieved. We attribute this to an additional flow inside the liquid bridge, which enhanced polymer dissolution. Even if the pendant drop is evaporating about 30 µm above the polymer surface without any contact (non-contact mode), concave structures were observed. Rim heights as high as 33 µm could be generated for exposure times of 20 min. The concave structure exclusively lay above the flat polymer surface outside the structure even after drying. This shows that toluene is taken up permanently. The increasing rim height, rh, with increasing exposure time to the solvent vapor obeys a diffusion law of rh = rh0  tn, with n in the range of 0.46 ~ 0.65. This hints at a non-Fickian swelling process. A detailed analysis showed that the rim height of the concave structure is modulated, unlike for the drop deposition. This is due to the local stress relaxation, which was initiated by the increasing toluene concentration in the extruded polymer surface. By altering the intrinsic material parameters i.e. the polymer molar mass and the polymer/solvent combination, several types of microstructures could be formed. With increasing molar mass from 20.9 kDa to 1.44 MDa the resulting microstructure changed from convex, to a structure with a dimple in the center, to concave, to finally an irregular structure. This observation can be explained if one assumes that the microstructuring is dominated by two opposing effects, a decreasing solubility with increasing polymer molar mass, but an increasing surface tension gradient leading to instabilities of Marangoni-type. Thus, a polymer with a low molar mass close or below the entanglement limit is subject to a high dissolution rate, which leads to fast gelation compared to the evaporation rate. This way a coffee-rim like effect is eliminated early and a convex structure results. For high molar masses the low dissolution rate and the low polymer diffusion might lead to increased surface tension gradients and a typical local pile-up of polymer is found. For intermediate polymer masses around 200 kDa, the dissolution and evaporation rate are comparable and the typical concave microtopology is found. This interpretation was supported by a quantitative estimation of the diffusion coefficient and the evaporation rate. For a different polymer/solvent system, polyethylmethacrylate (PEMA)/ethylacetate (EA), exclusively concave structures were found. Following the statements above this can be interpreted with a lower dissolution rate. At low molar masses the concentration of PEMA in EA most likely never reaches the gelation point. Thus, a concave instead of a convex structure occurs. At the end of this section, the optically properties of such microstructures for a potential application as microlenses are studied with laser scanning confocal microscopy. In the third part, the droplet was confined into a glass microcapillary to avoid evaporation. Since here, due to an increased area to volume ratio, the surface properties of the liquid and the solid walls became important, the influence of the surface hydrophilicity of the wall on the interfacial tension between two immiscible liquid slugs was investigated. For this a novel method for measuring the interfacial tension between the two liquids within the capillary was developed. This technique was demonstrated by measuring the interfacial tensions between slugs of pure water and standard solvents. For toluene, n-hexane and chloroform 36.2, 50.9 and 34.2 mN/m were measured at 20°C, which is in a good agreement with data from the literature. For a slug of hexane in contact with a slug of pure water containing ethanol in a concentration range between 0 and 70 (v/v %), a difference of up to 6 mN/m was found, when compared to commercial ring tensiometry. This discrepancy is still under debate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Advanced optical biosensor platforms exploiting long range surface plasmons (LRSPs) and responsive N-isopropylacrylamide (NIPAAm) hydrogel binding matrix for the detection of protein and bacterial pathogen analytes were carried out. LRSPs are optical waves that originate from coupling of surface plasmons on the opposite sites of a thin metallic film embedded between two dielectrics with similar refractive indices. LRSPs exhibit orders of magnitude lower damping and more extended profile of field compared to regular surface plasmons (SPs). Their excitation is accompanied with narrow resonance and provides stronger enhancement of electromagnetic field intensity that can advance the sensitivity of surface plasmon resonance (SPR) and surface plasmon-enhanced fluorescence spectroscopy (SPFS) biosensors. Firstly, we investigated thin gold layers deposited on fluoropolymer surface for the excitation of LRSPs. The study indicates that the morphological, optical and electrical properties of gold film can be changed by the surface energy of fluoropolymer and affect the performance of a SPFS biosensor. A photo-crosslinkable NIPAAm hydrogel was grafted to the sensor surface in order to serve as a binding matrix. It was modified with bio-recognition elements (BREs) via amine coupling chemistry and offered the advantage of large binding capacity, stimuli responsive properties and good biocompatibility. Through experimental observations supported by numerical simulations describing diffusion mass transfer and affinity binding of target molecules in the hydrogel, the hydrogel binding matrix thickness, concentration of BREs and the profile of the probing evanescent field was optimized. Hydrogel with a up to micrometer thickness was shown to support additional hydrogel optical waveguide (HOW) mode which was employed for probing affinity binding events in the gel by means of refractometric and fluorescence measurements. These schemes allow to reach limits of detection (LODs) at picomolar and femtomolar levels, respectively. Besides hydrogel based experiments for detection of molecular analytes, long range surface plasmon-enhanced fluorescence spectroscopy (LRSP-FS) was employed for detection of bacterial pathogens. The influence of capture efficiency of bacteria on surfaces and the profile of the probing field on sensor response were investigated. The potential of LRSP-FS with extended evanescent field is demonstrated for detection of pathogenic E. coli O157:H7 on sandwich immunoassays . LOD as low as 6 cfu mL-1 with a detection time of 40 minutes was achieved.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The adsorption of particles and surfactants at water-oil interfaces has attracted continuous attention because of its emulsion stabilizing effect and the possibility to form two-dimensional materials. Herein, I studied the interfacial diffusion of single molecules and nanoparticles at water-oil interfaces using fluorescence correlation spectroscopy. rnrnFluorescence correlation spectroscopy (FCS) is a promising technique to study diffusion of fluorescent tracers in diverse conditions. This technique monitors and analyzes the fluorescence fluctuation caused by single fluorescent tracers coming in and out of a diffraction-limited observation volume “one at a time”. Thus, this technique allows a combination of high precision, high spatial resolution and low tracer concentration. rnrnIn chapter 1, I discussed some controversial questions regarding the properties of water-hydrophobic interfaces and also introduced the current progress on the stability and dynamic of single nanoparticles at water-oil interfaces. The materials and setups I used in this thesis were summarized in chapter 2. rnrnIn chapter 3, I presented a new strategy to study the properties of water-oil interfaces. The two-dimensional diffusion of isolated molecular tracers at water/n-alkane interfaces was measured using fluorescence correlation spectroscopy. The diffusion coefficients of larger tracers with a hydrodynamic radius of 4.0 nm agreed well with the values calculated from the macroscopic viscosities of the two bulk phases. However, for small molecule tracers with hydrodynamic radii of only 1.0 and 0.6 nm, notable deviations were observed, indicating the existence of an interfacial region with a reduced effective viscosity. rnrnIn chapter 4, the interfacial diffusion of nanoparticles at water-oil interfaces was investigated using FCS. In stark contrast to the interfacial diffusion of molecular tracers, that of nanoparticles at any conditions is slower than the values calculated in accordance to the surrounding viscosity. The diffusion of nanoparticles at water-oil interfaces depended on the interfacial tension of liquid-liquid interfaces, the surface properties of nanoparticles, the particle sizes and the viscosities of surrounding liquid phases. In addition, the interfacial diffusion of nanoparticles with Janus motif is even slower than that of their symmetric counterparts. Based on the experimental results I obtained, I drew some possibilities to describe the origin of nanoparticle slowdown at water-oil interfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die vorliegende Arbeit wurde im Rahmen des BMWi-Verbundprojektes Wechselwirkung und Transport von Aktiniden im natürlichen Tongestein unter Berücksichtigung von Huminstoffen und Tonorganika – Wechselwirkung von Neptunium und Plutonium mit natürlichem Tongestein“ durchgeführt. Um die langfristige Sicherheit der nuklearen Endlager beurteilen zu können, muss eine mögliche Migration der radiotoxischen Abfälle in die Umwelt betrachtet werden. Wegen seiner langen Halbwertszeit (24000 a) leistet Pu-239 einen wesentlichen Beitrag zur Radiotoxizität abgebrannter Kernbrennstoffe in einem Endlager. Das redox-sensitive Pu tritt in Lösung unter umweltrelevanten Bedingungen in den Oxidationsstufen +III bis +VI auf und kann nebeneinander in bis zu vier Oxidationsstufen vorliegen. Tonsteinformationen werden als mögliches Wirtsgestein für Endlager hoch-radioaktiver Abfälle betrachtet. Deshalb sind ausführliche Informationen zur Mobilisierung und Immobilisierung des Pu durch/in das Grundwasser aus einem Endlager von besonderer Bedeutung. In dieser Arbeit wurden neue Erkenntnisse über die Wechselwirkung zwischen Pu und dem natürlichen Tongestein Opalinuston (OPA, Mont Terri, Schweiz) mit Hinblick auf die Endlagerung wärmeentwickelnder radioaktiver Abfälle in einem geologischen Tiefenlager gewonnen.rnDer Fokus der Arbeit lag dabei auf der Bestimmung der Speziation von Pu an der Mineraloberfläche nach Sorptions- und Diffusionsprozessen mittels verschiedener synchrotronbasierter Methoden (µ-XRF, µ-XANES/EXAFS, µ-XRD, XANES/EXAFS). rnDie Wechselwirkung zwischen Pu und OPA wurde zunächst in Batch- und Diffusionsexperimenten in Abhängigkeit verschiedener experimenteller Parameter (u.a. pH, Pu-Oxidationsstufe) untersucht. In Sorptionsexperimenten konnte gezeigt werden, dass einige Parameter (z.B. Temperatur, Huminsäure) einen deutlichen Einfluss auf die Sorption von Pu haben.rnDie Speziationsuntersuchungen wurden zum einen an Pulverproben aus Batchexperimenten und zum anderen an OPA-Dünnschliffen bzw. Diffusionsproben in Abhängigkeit verschiedener experimenteller Parameter durchgeführt. Die EXAFS-Messungen an der Pu LIII-Kante der Pulverproben ergaben, dass eine innersphäriche Sorption von Pu(IV) an Tongestein unabhängig von dem Ausgangsoxidationszustand des Plutoniums in Lösung stattgefunden hat. Durch die Kombination der ortsaufgelösten Methoden wurde erstmalig mittels μ-XRF die Verteilung von Pu und anderen in OPA enthaltenen Elementen bestimmt. µ-XANES-Spektren an Pu-Anreicherungen auf OPA-Dünnschliffen und in Diffusionsproben bestätigen, dass das weniger mobile Pu(IV) die dominierende Spezies nach den Sorptions- und Diffusionsprozessen ist. Darüber hinaus wurde zum ersten Mal ein Diffusionsprofil von Pu in OPA mittels µ-XRF gemessen. Die Speziationsuntersuchungen mittels μ-XANES zeigten, dass das eingesetzte Pu(V) entlang seines Diffusionspfades zunehmend zu Pu(IV) reduziert wird. Mit µ-XRD wurde Illit als dominierende Umgebung, in der Pu angereichert wurde, identifiziert und Siderit als eine redoxaktive Phase auftreten kann. Die Ergebnisse dieser Arbeit zeigen, dass die Sicherheit von OPA als Wirtsgestein eines Endlagers hoch-radioaktiver Abfälle positiv zu bewerten ist. rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die salpetrige Säure (HONO) ist eine der reaktiven Stickstoffkomponenten der Atmosphäre und Pedosphäre. Die genauen Bildungswege von HONO, sowie der gegenseitige Austausch von HONO zwischen Atmosphäre und Pedosphäre sind noch nicht vollständig aufgedeckt. Bei der HONO-Photolyse entsteht das Hydroxylradikal (OH) und Stickstoffmonooxid (NO), was die Bedeutsamkeit von HONO für die atmosphärische Photochemie widerspiegelt.rnUm die genannte Bildung von HONO im Boden und dessen anschließenden Austausch mit der Atmosphäre zu untersuchen, wurden Messungen von Bodenproben mit dynamischen Kammern durchgeführt. Im Labor gemessene Emissionsflüsse von Wasser, NO und HONO zeigen, dass die Emission von HONO in vergleichbarem Umfang und im gleichen Bodenfeuchtebereich wie die für NO (von 6.5 bis 56.0 % WHC) stattfindet. Die Höhe der HONO-Emissionsflüsse bei neutralen bis basischen pH-Werten und die Aktivierungsenergie der HONO-Emissionsflüsse führen zu der Annahme, dass die mikrobielle Nitrifikation die Hauptquelle für die HONO-Emission darstellt. Inhibierungsexperimente mit einer Bodenprobe und die Messung einer Reinkultur von Nitrosomonas europaea bestärkten diese Theorie. Als Schlussfolgerung wurde das konzeptionelle Model der Bodenemission verschiedener Stickstoffkomponenten in Abhängigkeit von dem Wasserhaushalt des Bodens für HONO erweitert.rnIn einem weiteren Versuch wurde zum Spülen der dynamischen Kammer Luft mit erhöhtem Mischungsverhältnis von HONO verwendet. Die Messung einer hervorragend charakterisierten Bodenprobe zeigte bidirektionale Flüsse von HONO. Somit können Böden nicht nur als HONO-Quelle, sondern auch je nach Bedingungen als effektive Senke dienen. rnAußerdem konnte gezeigt werden, dass das Verhältnis von HONO- zu NO-Emissionen mit dem pH-Wert des Bodens korreliert. Grund könnte die erhöhte Reaktivität von HONO bei niedrigem pH-Wert und die längere Aufenthaltsdauer von HONO verursacht durch reduzierte Gasdiffusion im Bodenporenraum sein, da ein niedriger pH-Wert mit erhöhter Bodenfeuchte am Maximum der Emission einhergeht. Es konnte gezeigt werden, dass die effektive Diffusion von Gasen im Bodenporenraum und die effektive Diffusion von Ionen in der Bodenlösung die HONO-Produktion und den Austausch von HONO mit der Atmosphäre begrenzen. rnErgänzend zu den Messungen im Labor wurde HONO während der Messkampagne HUMPPA-COPEC 2010 im borealen Nadelwald simultan in der Höhe von 1 m über dem Boden und 2 bis 3 m über dem Blätterdach gemessen. Die Budgetberechnungen für HONO zeigen, dass für HONO sämtliche bekannte Quellen und Senken in Bezug auf die übermächtige HONO-Photolyserate tagsüber vernachlässigbar sind (< 20%). Weder Bodenemissionen von HONO, noch die Photolyse von an Oberflächen adsorbierter Salpetersäure können die fehlende Quelle erklären. Die lichtinduzierte Reduktion von Stickstoffdioxid (NO2) an Oberflächen konnte nicht ausgeschlossen werden. Es zeigte sich jedoch, dass die fehlende Quelle stärker mit der HONO-Photolyserate korreliert als mit der entsprechenden Photolysefrequenz, die proportional zur Photolysefrequenz von NO2 ist. Somit lässt sich schlussfolgern, dass entweder die Photolyserate von HONO überschätzt wird oder dass immer noch eine unbekannte, HONO-Quelle existiert, die mit der Photolyserate sehr stark korreliert. rn rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biosensors find wide application in clinical diagnostics, bioprocess control and environmental monitoring. They should not only show high specificity and reproducibility but also a high sensitivity and stability of the signal. Therefore, I introduce a novel sensor technology based on plasmonic nanoparticles which overcomes both of these limitations. Plasmonic nanoparticles exhibit strong absorption and scattering in the visible and near-infrared spectral range. The plasmon resonance, the collective coherent oscillation mode of the conduction band electrons against the positively charged ionic lattice, is sensitive to the local environment of the particle. I monitor these changes in the resonance wavelength by a new dark-field spectroscopy technique. Due to a strong light source and a highly sensitive detector a temporal resolution in the microsecond regime is possible in combination with a high spectral stability. This opens a window to investigate dynamics on the molecular level and to gain knowledge about fundamental biological processes.rnFirst, I investigate adsorption at the non-equilibrium as well as at the equilibrium state. I show the temporal evolution of single adsorption events of fibrinogen on the surface of the sensor on a millisecond timescale. Fibrinogen is a blood plasma protein with a unique shape that plays a central role in blood coagulation and is always involved in cell-biomaterial interactions. Further, I monitor equilibrium coverage fluctuations of sodium dodecyl sulfate and demonstrate a new approach to quantify the characteristic rate constants which is independent of mass transfer interference and long term drifts of the measured signal. This method has been investigated theoretically by Monte-Carlo simulations but so far there has been no sensor technology with a sufficient signal-to-noise ratio.rnSecond, I apply plasmonic nanoparticles as sensors for the determination of diffusion coefficients. Thereby, the sensing volume of a single, immobilized nanorod is used as detection volume. When a diffusing particle enters the detection volume a shift in the resonance wavelength is introduced. As no labeling of the analyte is necessary the hydrodynamic radius and thus the diffusion properties are not altered and can be studied in their natural form. In comparison to the conventional Fluorescence Correlation Spectroscopy technique a volume reduction by a factor of 5000-10000 is reached.