8 resultados para SYSTEMATIC-ERROR CORRECTION

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology. In this thesis, a measurement of the proton recoil spectrum with the spectrometer aSPECT is described. From this spectrum the antineutrino-electron angular correlation coefficient a can be derived. In our first beam time at the FRM II in Munich, background instabilities prevented us from presenting a new value for a. In the latest beam time at the ILL in Grenoble, the background has been reduced sufficiently. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The aim of the latest beam time was a new value for a with an error well below the present literature value of 4%. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, too high to determine a meaningful result. This thesis focused on the investigation of different systematic effects. With the knowledge of the systematics gained in this thesis, we are able to improve aSPECT to perform a 1% measurement of a in a further beam time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Das Ziel des Experiments NA48 am CERN ist die Messung des Parameters Re(epsilon'/epsilon) der direktenCP-Verletzung mit einer Genauigkeit von 2x10^-4. Experimentell zugänglich ist das DoppelverhältnisR, das aus den Zerfällen des KL und KS in zwei neutrale bzw. zwei geladene Pionengebildet wird. Für R gilt in guter Näherung: R=1-6Re(epsilon'/epsilon).
NA48 verwendet eine Wichtung der KL-Ereignisse zur Reduzierung der Sensitivität auf dieDetektorakzeptanz. Zur Kontrolle der bisherigen Standardanalyse wurde eine Analyse ohne Ereigniswichtung durchgeführt. Das Ergebnis derungewichteten Analyse wird in dieser Arbeit vorgestellt. Durch Verzicht auf die Ereigniswichtung kann derstatistische Anteil des Gesamtfehlers deutlich verringert werden. Da der limitierende Kanal der Zerfall deslanglebigen Kaons in zwei neutrale Pionen ist, ist die Verwendung der gesamten Anzahl derKL-Zerfälle ein lohnendes Ziel.Im Laufe dieser Arbeit stellte sich heraus, dass dersystematische Fehler der Akzeptanzkorrektur diesen Gewinn wieder aufhebt.

Das Ergebnis der Arbeit für die Daten aus den Jahren 1998und 1999 ohne Ereigniswichtung lautet
Re(epsilon'/epsilon)=(17,91+-4,41(syst.)+-1,36(stat.))x10^-4.
Damit ist eindeutig die Existenz der direkten CP-Verletzungbestätigt. Dieses Ergebnis ist mit dem veröffentlichten Ergebnis vonNA48 verträglichSomit ist der Test der bisherigen Analysestrategie bei NA48erfolgreich durchgeführt worden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die Drei-Spektrometer-Anlage am Mainzer Institut für Kernphysik wurde um ein zusätzliches Spektrometer ergänzt, welches sich durch seine kurze Baulänge auszeichnet und deshalb Short-Orbit-Spektrometer (SOS) genannt wird. Beim nominellen Abstand des SOS vom Target (66 cm) legen die nachzuweisenden Teilchen zwischen Reaktionsort und Detektor eine mittlere Bahnlänge von 165 cm zurück. Für die schwellennahe Pionproduktion erhöht sich dadurch im Vergleich zu den großen Spektrometern die Überlebenswahrscheinlichkeit geladener Pionen mit Impuls 100 MeV/c von 15% auf 73%. Demzufolge verringert sich der systematische Fehler ("Myon-Kontamination"), etwa bei der geplanten Messung der schwachen Formfaktoren G_A(Q²) und G_P(Q²), signifikant. Den Schwerpunkt der vorliegenden Arbeit bildet die Driftkammer des SOS. Ihre niedrige Massenbelegung (0,03% X_0) zur Reduzierung der Kleinwinkelstreuung ist auf den Nachweis niederenergetischer Pionen hin optimiert. Aufgrund der neuartigen Geometrie des Detektors musste eine eigene Software zur Spurrekonstruktion, Effizienzbestimmung etc. entwickelt werden. Eine komfortable Möglichkeit zur Eichung der Driftweg-Driftzeit-Relation, die durch kubische Splines dargestellt wird, wurde implementiert. Das Auflösungsvermögen des Spurdetektors liegt in der dispersiven Ebene bei 76 µm für die Orts- und 0,23° für die Winkelkoordinate (wahrscheinlichster Fehler) sowie entsprechend in der nicht-dispersiven Ebene bei 110 µm bzw. 0,29°. Zur Rückrechnung der Detektorkoordinaten auf den Reaktionsort wurde die inverse Transfermatrix des Spektrometers bestimmt. Hierzu wurden an Protonen im ¹²C-Kern quasielastisch gestreute Elektronen verwendet, deren Startwinkel durch einen Lochkollimator definiert wurden. Daraus ergeben sich experimentelle Werte für die mittlere Winkelauflösung am Target von sigma_phi = 1,3 mrad bzw. sigma_theta = 10,6 mrad. Da die Impulseichung des SOS nur mittels quasielastischer Streuung (Zweiarmexperiment) durchgeführt werden kann, muss man den Beitrag des Protonarms zur Breite des Piks der fehlenden Masse in einer Monte-Carlo-Simulation abschätzen und herausfalten. Zunächst lässt sich nur abschätzen, dass die Impulsauflösung sicher besser als 1% ist.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dieser Arbeit wurden umfangreiche laserspektroskopische Studien mit dem Zielrneines verbesserten Verständnisses höchst komplexer Spektren der Lanthanide und Aktinide durchgeführt. Einen Schwerpunkt bildete die Bestimmung bisher nicht oder mit unbefriedigender Genauigkeit bekannter erster Ionisationspotentiale für diese Elemente.rnHierzu wurden drei unterschiedliche experimentelle Methoden eingesetzt. Die Bestimmung des Ionisationspotentiales aus Rydbergserien wurde an den Beispielen Eisen, Mangan und Kobalt mit gemessenen Werten von IPFe = 63737, 6 ± 0, 2stat ± 0, 1syst cm−1, IPMn = 59959, 6 ± 0, 4 cm−1 beziehungsweise IPCo = 63564, 77 ± 0, 12 cm−1 zunächst erfolgreich erprobt. Die bestehenden Literaturwerte konnten in diesen Fällen bestätigt werden und bei Eisen und Kobalt die Genauigkeit etwa um einen Faktor drei bzw. acht verbessert werden. Im Falle der Lanthaniden und Aktiniden jedoch ist die Komplexität der Spektren derart hoch, dass Rydbergserien in einer Vielzahl weiterer Zustände beliebiger Konfiguration nicht oder kaum identifiziert werden können.rnUm dennoch das Ionisationspotential bestimmen zu können, wurde die verzögerte, gepulste Feldionisation wie auch das Verfahren der Isolated Core Excitation am Beispiel des Dysprosiums erprobt. Aus den so identifizierten Rydbergserien konnten Werte von IPFeld = 47899 ± 3 cm−1 beziehungsweise IPICE = 47900, 4 ± 1, 4 cm−1 bestimmt werden. Als komplementärer Ansatz, der auf ein möglichst reichhaltiges Spektrum in der Nähe des Ionisationspotentiales angewiesen ist, wurde zusätzlich die Sattelpunktsmethode erfolgreich eingesetzt. Das Ionisationspotential des Dysprosium wurde damit zu IPDy = 47901, 8±0, 3 cm−1 bestimmt, wobei am Samarium, dessen Ionisationspotential aus der Literatur mit höchster Genauigkeit bekannt ist, bestätigt werden konnte, dassrnauftretende systematische Fehler kleiner als 1 cm−1 sind. Das bisher sehr ungenau bekannte Ionisationspotential des Praseodyms wurde schließlich zu IPPr = 44120, 0 ± 0, 6 cm−1 gemessen. Hiermit wird der bisherige Literaturwert bei einer Verbesserung der Genauigkeit um zwei Größenordnungen um etwa 50 cm−1 nach oben korrigiert. Aus der Systematik der Ionisationspotentiale der Lanthaniden konnte schließlich das Ionisationspotential des radioaktiven Promethiums mit IPPm = 44985 ± 140 cm−1 vorhergesagt werden. Abschließend wurde die Laserresonanzionisation des Elements Protactinium demonstriertrnund das Ionisationspotential erstmals experimentell bestimmt. Ein Wert vonrn49000±110 cm−1 konnte aus dem charakteristischen Verhalten verschiedener Anregungsschemata gefolgert werden. Dieser Wert liegt etwa 1500 cm−1 höher als der bisherige Literaturwert, theoretische Vorhersagen weichen ebenfalls stark ab. Beide Abweichungen können über eine Betrachtung der Systematik der Ionisationspotentiale in der Aktinidenreihe hervorragend verstanden werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis presents an analysis for the search of Supersymmetry with the ATLAS detector at the LHC. The final state with one lepton, several coloured particles and large missing transverse energy was chosen. Particular emphasis was placed on the optimization of the requirements for lepton identification. This optimization showed to be particularly useful when combining with multi-lepton selections. The systematic error associated with the higher order QCD diagrams in Monte Carlo production is given particular focus. Methods to verify and correct the energy measurement of hadronic showers are developed. Methods for the identification and removal of mismeasurements caused by the detector are found in the single muon and four jet environment are applied. A new detector simulation system is shown to provide good prospects for future fast Monte Carlo production. The analysis was performed for $35pb^{-1}$ and no significant deviation from the Standard Model is seen. Exclusion limits subchannel for minimal Supergravity. Previous limits set by Tevatron and LEP are extended.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Plasmonic nanoparticles exhibit strong light scattering efficiency due to the oscillations of their conductive electrons (plasmon), which are excited by light. For rod-shaped nanoparticles, the resonance position is highly tunable by the aspect ratio (length/width) and the sensitivity to changes in the refractive index in the local environment depends on their diameter, hence, their volume. Therefore, rod-shaped nanoparticles are highly suitable as plasmonic sensors.rnWithin this thesis, I study the formation of gold nanorods and nanorods from a gold-copper alloy using a combination of small-angle X-ray scattering and optical extinction spectroscopy. The latter represents one of the first metal alloy nanoparticle synthesis protocols for producing rod-shaped single crystalline gold-copper (AuxCu(1-x)) alloyed nanoparticles. I find that both length and width independently follow an exponential growth behavior with different time-constants, which intrinsically leads to a switch between positive and negative aspect ratio growth during the course of the synthesis. In a parameter study, I find linear relations for the rate constants as a function of [HAuCl4]/[CTAB] ratio and [HAuCl4]/[seed] ratio. Furthermore, I find a correlation of final aspect ratio and ratio of rate constants for length and width growth rate for different [AgNO3]/[HAuCl4] ratios. I identify ascorbic acid as the yield limiting species in the reaction by the use of spectroscopic monitoring and TEM. Finally, I present the use of plasmonic nanorods that absorb light at 1064nm as contrast agents for photoacoustic imaging (BMBF project Polysound). rnIn the physics part, I present my automated dark-field microscope that is capable of collecting spectra in the range of 450nm to 1750 nm. I show the characteristics of that setup for the spectra acquisition in the UV-VIS range and how I use this information to simulate measurements. I show the major noise sources of the measurements and ways to reduce the noise and how the combination of setup charactersitics and simulations of sensitivity and sensing volume can be used to select appropriate gold rods for single unlabeled protein detection. Using my setup, I show how to estimate the size of gold nano-rods directly from the plasmon linewidth measured from optical single particle spectra. Then, I use this information to reduce the distribution (between particles) of the measured plasmonic sensitivity S by 30% by correcting for the systematic error introduced from the variation in particle size. I investigate the single particle scattering of bowtie structures — structures consisting of two (mostly) equilateral triangles pointing one tip at each other. I simulate the spectra of the structures considering the oblique illumination angle in my setup, which leads to additional plasmon modes in the spectra. The simulations agree well with the measurements form a qualitative point of view.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Im Rahmen des A4-Experiments werden die Beiträge des Strange-Quarks zu den elektromagnetischen Formfaktoren des Protons gemessen. Solche Seequarkeffekte bei Niederenergieobservablen sind für das Verständnis der Hadronenstruktur wichtig, denn sie stellen eine direkte Manifestation der QCD-Freiheitsgrade im nichtperturbativen Bereich dar.rnrnLinearkombinationen der Strangeness-Vektorformfaktoren des Protons $G_E^s$ und $G_M^s$ sind experimentell über die Messung der paritätsverletzenden Asymmetrie im Wirkungsquerschnitt der elastischen Streuung longitudinal polarisierter Elektronen an unpolarisierten Nukleonen zugänglich. Vor dieser Arbeit hatte die A4-Kollaboration zwei solche Messungen unter Vorwärtsstreuwinkeln bei den Viererimpulsübertägen $Q^2$ von jeweils 0.23 und 0.10 (GeV/c)$^2$ veröffentlicht. Um die Separation von $G_E^s$ und $G_M^s$ beim höheren $Q^2$-Wert zu erhalten, wurde eine Messung unter Rückwärtswinkeln mit der Strahlenergie von 315 MeV durchgeführt.rnrnIm A4-Experiment werden die an einem Flüssigwasserstoff-Target gestreuten Elektronen eines longitudinal polarisierten Strahls mit einem Cherenkov-Kalorimeter einzeln gezählt. Durch die kalorimetrische Energiemessung erfolgt die Trennung der elastischen von den inelastischen Ereignissen. Bei Rückwärtswinkeln wurde dieses Apparat mit einem Szintillator als Elektronentagger erweitert, um den $\gamma$-Untergrund aus dem $\pi^0$-Zerfall zu unterdrücken.rnrnUm die Auswertung dieser Messung zu ermöglichen, wurden im Rahmen dieser Arbeit die gemessenen Energiespektren anhand von ausführlichen Simulationen der Streuprozesse und des Antwortverhaltens der Detektoren untersucht, und eine Methode zur Behandlung des restlichen Untergrunds aus der $\gamma$-Konversionrnvor dem Szintillator entwickelt. Die Simulationergebnisse sind auf dem 5%-Niveau mit den Messungen verträglich, und es wurde bewiesen, dass die Methode der Untergrundbehandlung anwendbar ist.rnrnDie Asymmetriemessung bei Rückwärtswinkeln, die man nach Anwendung der hier erarbeiteten Untergrundbehandlung erhält, wurde für die Separation von $G_E^s$ und $G_M^s$ bei $Q^2$=0.22 (GeV/c)^2 mit der Vorwärtswinkelmessung beim selbenrn$Q^2$ kombiniert. Es ergeben sich die Werte:rnrn$G_M^s$= -0.14 ± 0.11_{exp} ± 0.11_{theo} undrn$G_E^s$= 0.050 ± 0.038_{exp} ± 0.019_{theo}, rnrnwobei die systematische Unsicherheit wegen der Untergrundbehandlung im experimentellen Fehler enthalten ist. Am Ende der Arbeit werden die aus diesen Resultaten folgenden Rückschlüsse auf den Einfluss der Strangeness auf die statischen elektromagnetischen Eigenschaften des Protons diskutiert.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das aSPECT Spektrometer wurde entworfen, um das Spektrum der Protonen beimrnZerfall freier Neutronen mit hoher Präzision zu messen. Aus diesem Spektrum kann dann der Elektron-Antineutrino Winkelkorrelationskoeffizient "a" mit hoher Genauigkeit bestimmt werden. Das Ziel dieses Experiments ist es, diesen Koeffizienten mit einem absoluten relativen Fehler von weniger als 0.3% zu ermitteln, d.h. deutlich unter dem aktuellen Literaturwert von 5%.rnrnErste Messungen mit dem aSPECT Spektrometer wurden an der Forschungsneutronenquelle Heinz Maier-Leibnitz in München durchgeführt. Jedoch verhinderten zeitabhängige Instabilitäten des Meßhintergrunds eine neue Bestimmung von "a".rnrnDie vorliegende Arbeit basiert hingegen auf den letzten Messungen mit dem aSPECTrnSpektrometer am Institut Laue-Langevin (ILL) in Grenoble, Frankreich. Bei diesen Messungen konnten die Instabilitäten des Meßhintergrunds bereits deutlich reduziert werden. Weiterhin wurden verschiedene Veränderungen vorgenommen, um systematische Fehler zu minimieren und um einen zuverlässigeren Betrieb des Experiments sicherzustellen. Leider konnte aber wegen zu hohen Sättigungseffekten der Empfängerelektronik kein brauchbares Ergebnis gemessen werden. Trotzdem konnten diese und weitere systematische Fehler identifiziert und verringert, bzw. sogar teilweise eliminiert werden, wovon zukünftigernStrahlzeiten an aSPECT profitieren werden.rnrnDer wesentliche Teil der vorliegenden Arbeit befasst sich mit der Analyse und Verbesserung der systematischen Fehler, die durch das elektromagnetische Feld aSPECTs hervorgerufen werden. Hieraus ergaben sich vielerlei Verbesserungen, insbesondere konnten die systematischen Fehler durch das elektrische Feld verringert werden. Die durch das Magnetfeld verursachten Fehler konnten sogar soweit minimiert werden, dass nun eine Verbesserung des aktuellen Literaturwerts von "a" möglich ist. Darüber hinaus wurde in dieser Arbeit ein für den Versuch maßgeschneidertes NMR-Magnetometer entwickelt und soweit verbessert, dass nun Unsicherheiten bei der Charakterisierung des Magnetfeldes soweit reduziert wurden, dass sie für die Bestimmung von "a" mit einer Genauigkeit von mindestens 0.3% vernachlässigbar sind.