3 resultados para SME

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of violation of CPT- and Lorentz Symmetry, the minimal Standard Model Extension (SME) of Kostelecky and coworkers predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3He and 129Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times of up to 4.4 h for 129Xe and 14.1 h for 3He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted difference of the 3He and 129Xe frequencies or phases. The Lorentz-violating SME parameters for the neutron are determined out of a fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The result of the fit gives an upper limit for the equatorial component of the neutron parameter b_n of 3.7×10^(−32) GeV at the 95% confidence level. This value is not limited by the signal-to-noise ratio, but by the strong correlations between the fit parameters. To reduce the correlations and therewith improve the sensitivity of future experiments, it will be necessary to change the time structure of the weighted phase difference, which can be realized by increasing the 129Xe relaxation time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Invarianz physikalischer Gesetze unter Lorentztransformationen ist eines der fundamentalen Postulate der modernen Physik und alle Theorien der grundlegenden Wechselwirkungen sind in kovarianter Form formuliert. Obwohl die Spezielle Relativitätstheorie (SRT) in einer Vielzahl von Experimenten mit hoher Genauigkeit überprüft und bestätigt wurde, sind aufgrund der weitreichenden Bedeutung dieses Postulats weitere verbesserte Tests von grundsätzlichem Interesse. Darüber hinaus weisen moderne Ansätze zur Vereinheitlichung der Gravitation mit den anderen Wechselwirkungen auf eine mögliche Verletzung der Lorentzinvarianz hin. In diesem Zusammenhang spielen Ives-Stilwell Experimente zum Test der Zeitdilatation in der SRT eine bedeutende Rolle. Dabei wird die hochauflösende Laserspektroskopie eingesetzt, um die Gültigkeit der relativistischen Dopplerformel – und damit des Zeitdilatationsfaktors γ – an relativistischen Teilchenstrahlen zu untersuchen. Im Rahmen dieser Arbeit wurde ein Ives-Stilwell Experiment an 7Li+-Ionen, die bei einer Geschwindigkeit von 34 % der Lichtgeschwindigkeit im Experimentierspeicherring (ESR) des GSI Helmholtzzentrums für Schwerionenforschung gespeichert waren, durchgeführt. Unter Verwendung des 1s2s3S1→ 1s2p3P2-Übergangs wurde sowohl Λ-Spektroskopie als auch Sättigungsspektroskopie betrieben. Durch die computergestützte Analyse des Fluoreszenznachweises und unter Verwendung optimierter Kantenfilter für den Nachweis konnte das Signal zu Rauschverhältnis entscheidend verbessert und unter Einsatz eines zusätzlichen Pumplasers erstmals ein Sättigungssignal beobachtet werden. Die Frequenzstabilität der beiden verwendeten Lasersysteme wurde mit Hilfe eines Frequenzkamms spezifiziert, um eine möglichst hohe Genauigkeit zu erreichen. Die aus den Strahlzeiten gewonnen Daten wurden im Rahmen der Robertson-Mansouri-Sexl-Testtheorie (RMS) und der Standard Model Extension (SME) interpretiert und entsprechende Obergrenzen für die relevanten Testparameter der jeweiligen Theorie bestimmt. Die Obergrenze für den Testparameter α der RMS-Theorie konnte gegenüber den früheren Messungen bei 6,4 % der Lichtgeschwindigkeit am Testspeicherring (TSR) des Max-Planck-Instituts für Kernphysik in Heidelberg um einen Faktor 4 verbessert werden.