16 resultados para Resonance Fluorescence-spectrum
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
The development and characterization of biomolecule sensor formats based on the optical technique Surface Plasmon Resonance (SPR) Spectroscopy and electrochemical methods were investigated. The study can be divided into two parts of different scope. In the first part new novel detection schemes for labeled targets were developed on the basis of the investigations in Surface-plamon Field Enhanced Spectroscopy (SPFS). The first one is SPR fluorescence imaging formats, Surface-plamon Field Enhanced Fluorescence Microscopy (SPFM). Patterned self assembled monolayers (SAMs) were prepared and used to direct the spatial distribution of biomolecules immobilized on surfaces. Here the patterned monolayers would serve as molecular templates to secure different biomolecules to known locations on a surface. The binding processed of labeled target biomolecules from solution to sensor surface were visually and kinetically recorded by the fluorescence microscope, in which fluorescence was excited by the evanescent field of propagating plasmon surface polaritons. The second format which also originates from SPFS technique, Surface-plamon Field Enhanced Fluorescence Spectrometry (SPFSm), concerns the coupling of a fluorometry to normal SPR setup. A spectrograph mounted in place of photomultiplier or microscope can provide the information of fluorescence spectrum as well as fluorescence intensity. This study also firstly demonstrated the analytical combination of surface plasmon enhanced fluorescence detection with analyte tagged by semiconducting nano- crystals (QDs). Electrochemically addressable fabrication of DNA biosensor arrays in aqueous environment was also developed. An electrochemical method was introduced for the directed in-situ assembly of various specific oligonucleotide catcher probes onto different sensing elements of a multi-electrode array in the aqueous environment of a flow cell. Surface plasmon microscopy (SPM) is utilized for the on-line recording of the various functionalization steps. Hybridization reactions between targets from solution to the different surface-bound complementary probes are monitored by surface-plasmon field-enhanced fluorescence microscopy (SPFM) using targets that are either labeled with organic dyes or with semiconducting quantum dots for color-multiplexing. This study provides a new approach for the fabrication of (small) DNA arrays and the recording and quantitative evaluation of parallel hybridization reactions. In the second part of this work, the ideas of combining the SP optical and electrochemical characterization were extended to tethered bilayer lipid membrane (tBLM) format. Tethered bilayer lipid membranes provide a versatile model platform for the study of many membrane related processes. The thiolipids were firstly self-assembled on ultraflat gold substrates. Fusion of the monolayers with small unilamellar vesicles (SUVs) formed the distal layer and the membranes thus obtained have the sealing properties comparable to those of natural membranes. The fusion could be monitored optically by SPR as an increase in reflectivity (thickness) upon formation of the outer leaflet of the bilayer. With EIS, a drop in capacitance and a steady increase in resistance could be observed leading to a tightly sealing membrane with low leakage currents. The assembly of tBLMs and the subsequent incorporation of membrane proteins were investigated with respect to their potential use as a biosensing system. In the case of valinomycin the potassium transport mediated by the ion carrier could be shown by a decrease in resistance upon increasing potassium concentration. Potential mediation of membrane pores could be shown for the ion channel forming peptide alamethicin (Alm). It was shown that at high positive dc bias (cis negative) Alm channels stay at relatively low conductance levels and show higher permeability to potassium than to tetramethylammonium. The addition of inhibitor amiloride can partially block the Alm channels and results in increase of membrane resistance. tBLMs are robust and versatile model membrane architectures that can mimic certain properties of biological membranes. tBLMs with incorporated lipopolysaccharide (LPS) and lipid A mimicking bacteria membranes were used to probe the interactions of antibodies against LPS and to investigate the binding and incorporation of the small antimicrobial peptide V4. The influence of membrane composition and charge on the behavior of V4 was also probed. This study displays the possibility of using tBLM platform to record and valuate the efficiency or potency of numerous synthesized antimicrobial peptides as potential drug candidates.
Resumo:
Im Rahmen dieser Arbeit wurde ein neuartiger Experimentaufbau -- das γ3 Experiment -- zur Messung von photoneninduzierten Kern-Dipolanregungen in stabilen Isotopen konzipiert und an der High Intensity γ-Ray Source (HIγS) an der Duke University installiert.rnDie hohe Energieauflösung und die hohe Nachweiseffizienz des Detektoraufbaus, welcher aus einer Kombination von LaBr Szintillatoren und hochreinen Germanium-Detektoren besteht, erlaubt erstmals die effiziente Messung von γ-γ-Koinzidenzen in Verbindung mit der Methode der Kernresonanzfluoreszenz.rnDiese Methode eröffnet den Zugang zum Zerfallsverhalten der angeregten Dipolzustände als zusätzlicher Observablen, die ein detaillierteres Verständnis der zugrunde liegenden Struktur dieser Anregungen ermöglicht.rnDer Detektoraufbau wurde bereits erfolgreich im Rahmen von zwei Experimentkampagnen in 2012 und 2013 für die Untersuchung von 13 verschiedenen Isotopen verwendet. Im Fokus dieser Arbeit stand die Analyse der Pygmy-Dipolresonanz (PDR) im Kern 140Ce im Energiebereich von 5,2 MeV bis 8,3 MeV basierend auf den mit dem γ3 Experimentaufbau gemessenen Daten. Insbesondere das Zerfallsverhalten der Zustände, die an der PDR beteiligt sind, wurde untersucht. Der Experimentaufbau, die Details der Analyse sowie die Resultate werden in der vorliegenden Arbeit präsentiert. Desweiteren erlaubt ein Vergleich der Ergebnisse mit theoretischen Rechnungen im quasi-particle phonon model (QPM) eine Interpretation des beobachteten Zerfallsverhaltens.
Resumo:
ABSTRACT This works aim was to test whether LTP-like features can also be measured in cell culture and by methods that allow to analyse a alrger number of cells. A suitable method for this purpose is calcium imaging. The rationale for this approach lies in the fact that LTP/LTD are dependent on changes in intracellular calcium concentrations. Calcium levels have been measured using the calcium sensitive dye fura-2, whose fluorescence spectrum changes upon formation of the [fura-2-Ca2+] complex. Our LTP-inducing protocol comprised of two glutamate stimuli of identical size and duration (50 mM, 30 s) which were separated by 35 min. We could demonstrate that such a stimulation pattern gives rise to approx. 25% larger calcium influx at the second stimulus. It has been shown than such a stimulation pattern gives rise to an average of 25% augmentation (potentiation) of the second response, with 69% of potentiated cells. This experimental paradigm shows the pharmacological properties of LTP, established by previous electrophysiological studies:- blocking of NMDARs and mGluRs eliminates LTP induction;- blocking of AMPARs and L-type VGCCs does not eliminate LTP induction. Having obtained a system for induction and following of LTP-like changes, a preliminary application example was performed. Its purpose was to investigate possible influence of nicotine and galanthamine on our potentiation effect. Nicotine (100 mM) was shown both to increase and to eliminate glutamate-induced potentiation. Galanthamine coapplication (0.5 mM) with nicotine and glutamate exerted no effect on nicotinic modulation. However, galanthamine coapplied with glutamate alone seems to augment glutamate-induced potentiation. An LTP model system presented here could be additionally refined, by variation of glutamate application times, and testing for dependence on various forms of protein kinases. Galanthamine effect would probably be better addressed by cell-to-cell measurements instead of statistical approach, with subsequent identification of the cell type. Alternatively, combined calcium imaging â electrophysiological experiments could be performed. Spatial and temporal properties of intracellular ion dynamics could be utilised as diagnostic tools of the physiological state of the cells, thereby finding its application in functional proteomics.
Resumo:
Der erste Teil dieser Arbeit befasst sich mit der Kinetik der Reaktion des OH-Radikals mit Glykolaldehyd (HOCH2CHO). Die Geschwindigkeitskonstante k1 wurde für diese Reaktion temperaturabhängig bestimmt. Durch gepulste Photolyse wurden OH-Radikale erzeugt. Anschließend wurde die laserinduzierte Fluoreszenz der OH-Radikale bei 309 nm detektiert. Die ermittelte Geschwindigkeitskonstante k1 für die Reaktion von OH mit HOCH2CHO von (8,0 ± 0,8) x 10-12 cm3 Teilchen-1 s-1 erweist sich für den Temperaturbereich von 240 K < T < 362 K als temperaturunabhängig. Zwischen 60 und 250 Torr kann zudem keine Druckabhängigkeit für k1 beobachtet werden. Die unerwartet niedrigere Geschwindigkeitskonstante für die betrachtete Reaktion im Vergleich zur Reaktion von OH mit CH3CHO konnte anhand von Überlegungen zur Korrelation zwischen der C-H-Bindungsstärke und dem H-Abstraktionskanal erklärt werden. Im zweiten Teil dieser Arbeit wurde die Photochemie von Aceton (CH3C(O)CH3), Methylethylketon (C2H5C(O)CH3, MEK) und Acetylbromid (CH3C(O)Br) betrachtet. Für die Photolyse von Aceton (bei 248 nm und 266 nm), MEK (bei 248 nm) und Acetylbromid (bei 248 nm) wurden bei 298 ± 3 K druckabhängig zwischen 5 und 1600 Torr N2 Quantenausbeuten für die Methylbildung (Phi(CH3)) bestimmt. Nach gepulster Photolyse der betrachteten Moleküle wurden die transienten Absorptionssignale der Methylradikale bei 216,4 nm verfolgt. Die Quantenausbeuten wurden relativ zur Photolyse von Methyliodid (CH3I) unter gleichen Reaktionsbedingungen ermittelt. Die erhaltenen Quantenausbeuten für CH3-Radikale nehmen für die beiden Systeme Aceton / 248 nm (Phi(CH3, Aceton) = 1,42 – 0,99) und MEK / 248 nm (Phi(CH3, MEK) = 0,45 – 0,19) druckabhängig zu hohen Drücken ab. Die Druckabhängigkeit von Phi(CH3) wird auf die Konkurrenz zwischen Stoßrelaxation und Dissoziation der schwingungsangeregten Acetylradikale (CH3CO#) zurückgeführt. Für das System Aceton / 266 nm wird keine Druckabhängigkeit von Phi(CH3) = 0,93 ± 0,1 beobachtet. Dies wird damit erklärt, dass CH3CO# nicht genügend Energie besitzt, um die Barriere zur Dissoziation zu überschreiten. Bei der Photolyse von Acetylbromid bei 248 nm wird druckunabhängig Phi(CH3) = 0,92 ± 0,10 bestimmt. In diesem System dissoziieren die schwingungsangeregten Acetylradikale bei allen Drücken vollständig. Bei 266 nm wurde die Gesamtquantenausbeute für die Photodissoziation von Aceton (Phi(diss, 266nm)) bestimmt. Die nach Photolyse erhaltenen Methyl - und Acetylradikale wurden nach Titration mit Br2 durch die Resonanzfluoreszenz der Bromatome detektiert. Phi(diss, 266nm) wurde mit 0,92 ± 0,07 bestimmt.
Resumo:
The aim of this work is to measure the stress inside a hard micro object under extreme compression. To measure the internal stress, we compressed ruby spheres (a-Al2O3: Cr3+, 150 µm diameter) between two sapphire plates. Ruby fluorescence spectrum shifts to longer wavelengths under compression and can be related to the internal stress by a conversion coefficient. A confocal laser scanning microscope was used to excite and collect fluorescence at desired local spots inside the ruby sphere with spatial resolution of about 1 µm3. Under static external loads, the stress distribution within the center plane of the ruby sphere was measured directly for the first time. The result agreed to Hertz’s law. The stress across the contact area showed a hemispherical profile. The measured contact radius was in accord with the calculation by Hertz’s equation. Stress-load curves showed spike-like decrease after entering non-elastic phase, indicating the formation and coalescence of microcracks, which led to relaxing of stress. In the vicinity of the contact area luminescence spectra with multiple peaks were observed. This indicated the presence of domains of different stress, which were mechanically decoupled. Repeated loading cycles were applied to study the fatigue of ruby at the contact region. Progressive fatigue was observed when the load exceeded 1 N. As long as the load did not exceed 2 N stress-load curves were still continuous and could be described by Hertz’s law with a reduced Young’s modulus. Once the load exceeded 2 N, periodical spike-like decreases of the stress could be observed, implying a “memory effect” under repeated loading cycles. Vibration loading with higher frequencies was applied by a piezo. Redistributions of intensity on the fluorescence spectra were observed and it was attributed to the repopulation of the micro domains of different elasticity. Two stages of under vibration loading were suggested. In the first stage continuous damage carried on until certain limit, by which the second stage, e.g. breakage, followed in a discontinuous manner.
Resumo:
Bei den Pflanzen sind viele Fragen bezüglich der Organisation und Regulation des bei der Zellteilung und differenzierung wichtigen Auf-, Ab- und Umbaus des Mikrotubuli-Netzwerkes noch immer offen, insbesondere was die Rolle des γ-Tubulins betrifft. Ziel der vorliegenden Arbeit war die Etablierung von BY-2 Modell-Zelllinien (Nicotiana), die verschiedene mit fluoreszierenden Proteinen (FP) markierte Elemente des Cytoskeletts exprimieren, um eine fluoreszenzmikroskopische Detektion in vivo zu ermöglichen.rnAls Grundlage für alle weiteren Versuche wurde eine zuverlässige Methode zur A. tumefaciens vermittelten stabilen Transfektion von BY-2 Zellen erarbeitet. Für die Expression von FP-markierten Cytoskelettproteinen, wurden entsprechende Fusionskonstrukte kloniert und via A. tumefaciens in BY-2 Zellen transferiert. So gelang zunächst die Herstellung transgener Zelllinien, die GFP-markiertes α- bzw. γ-Tubulin exprimierten. Diese sollten später als Basis für die Untersuchung des dynamischen Mikrotubuli-Netzwerkes bzw. dessen Regulation dienen. In beiden Zelllinien standen die Konstrukte zunächst unter Kontrolle eines doppelten 35S-Promotors, was zu einer starken, konstitutiven Expression der Transgene führte. Fluoreszenzmikroskopisch konnten Strukturen, an deren Aufbau Mikrotubuli beteiligt sind, detektiert werden. Aufgrund einer starken Hintergrundfluoreszenz, vermutlich bedingt durch die konstitutive Überexpression, war die Darstellung feinerer Bereiche, wie sie im Cytoskelett häufig auftreten, jedoch äußerst schwierig. Deshalb wurde eine schwächere bzw. adäquate Expressionsrate angestrebt. rnPhysiologische Expressionsraten sollten vor allem durch den endogenen γ-Tubulin-Promotor ermöglicht werden. Da die entsprechende Sequenz noch unbekannt war, wurde sie zunächst bestimmt und in ein passendes Konstrukt integriert. Fluoreszenzmikroskopische Untersuchungen der resultierenden Zelllinie ließen auf eine stark reduzierte Expressionsrate schließen. Tatsächlich war die Detektion von Cytoskelettstrukturen, wenn überhaupt, erst bei deutlich längeren Belichtungszeiten möglich. Bedingt durch die langen Belichtungszeiten wurde die Dokumentation durch eine latente pflanzentypische Autofluoreszenz der Zellen erschwert. Auch wenn hier keine detailreicheren Aufnahmen der Cytoskelettstrukturen möglich waren, ist die Zellkultur für weiterführende Untersuchungen, z.B. in Studien bezüglich des zeitlichen Expressionsmusters des γ-Tubulins, potentiell geeignet. Der Einsatz eines sensibleren Mikroskopsystems ist allerdings erforderlich. rnUm klären zu können, inwieweit γ-Tubulin mit den Mikrotubuli co-lokalisiert, wurden Zelllinien benötigt, bei denen die entsprechenden Elemente unterschiedlich markiert waren. Zu diesem Zweck wurde der Einsatz von RFP-markiertem Tubulin getestet. Eine deutliche Überexpression von RFP alleine war möglich. Trotz mehrfacher Wiederholung der Versuche war aber keine Expression von RFP-markiertem α-Tubulin in BY-2 Zellen zur Visualisierung der Mikrotubuli detektierbar. Die DNA-Sequenzen waren im Genom nachweisbar, eine Transkription jedoch nicht. Möglicherweise spielten hier gene silencing Effekte eine Rolle. Das verwendete RFP (TagRFP) und GFP stammten aus unterschiedlichen Organismen, aus einer Seeanemone bzw. einer Qualle. Eine Lösung könnte der Austausch des TagRFP durch ein Quallen-Derivat, das in einer von grün unterscheidbaren Farbe fluoresziert, bringen. Da bereits BY-2 Zelllinien vorliegen, die GFP-markiertes α- bzw. γ-Tubulin exprimieren, sollte es, nach Klonieren eines entsprechenden Konstruktes, zeitnah möglich sein, eine doppelt transfizierte Zelllinie herzustellen.
Resumo:
Advanced optical biosensor platforms exploiting long range surface plasmons (LRSPs) and responsive N-isopropylacrylamide (NIPAAm) hydrogel binding matrix for the detection of protein and bacterial pathogen analytes were carried out. LRSPs are optical waves that originate from coupling of surface plasmons on the opposite sites of a thin metallic film embedded between two dielectrics with similar refractive indices. LRSPs exhibit orders of magnitude lower damping and more extended profile of field compared to regular surface plasmons (SPs). Their excitation is accompanied with narrow resonance and provides stronger enhancement of electromagnetic field intensity that can advance the sensitivity of surface plasmon resonance (SPR) and surface plasmon-enhanced fluorescence spectroscopy (SPFS) biosensors. Firstly, we investigated thin gold layers deposited on fluoropolymer surface for the excitation of LRSPs. The study indicates that the morphological, optical and electrical properties of gold film can be changed by the surface energy of fluoropolymer and affect the performance of a SPFS biosensor. A photo-crosslinkable NIPAAm hydrogel was grafted to the sensor surface in order to serve as a binding matrix. It was modified with bio-recognition elements (BREs) via amine coupling chemistry and offered the advantage of large binding capacity, stimuli responsive properties and good biocompatibility. Through experimental observations supported by numerical simulations describing diffusion mass transfer and affinity binding of target molecules in the hydrogel, the hydrogel binding matrix thickness, concentration of BREs and the profile of the probing evanescent field was optimized. Hydrogel with a up to micrometer thickness was shown to support additional hydrogel optical waveguide (HOW) mode which was employed for probing affinity binding events in the gel by means of refractometric and fluorescence measurements. These schemes allow to reach limits of detection (LODs) at picomolar and femtomolar levels, respectively. Besides hydrogel based experiments for detection of molecular analytes, long range surface plasmon-enhanced fluorescence spectroscopy (LRSP-FS) was employed for detection of bacterial pathogens. The influence of capture efficiency of bacteria on surfaces and the profile of the probing field on sensor response were investigated. The potential of LRSP-FS with extended evanescent field is demonstrated for detection of pathogenic E. coli O157:H7 on sandwich immunoassays . LOD as low as 6 cfu mL-1 with a detection time of 40 minutes was achieved.rn
Resumo:
This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn
Resumo:
Die differentielle Hyperfeinanomalie beschreibt den Isotopieeffekt der magnetischen Hyperfeinwechselwirkung und stellt eine Testmöglichkeit für Kernmodelle dar. Nachdem in einer Reihe von Messungen die A-Faktoren der Hyperfeinwechselwirkung im Grundzustand von zwei stabilen und fünf instabilen Europium-Isotopen bestimmt wurden, sollen nun die Kern-g-Faktoren der gleichen Isotope bestimmt werden.Um die Kern-g-Faktoren zu bestimmen, wurden zunächst die Termschemata des Grundzustandesder stabilen Isotope 151,153Eu+ simuliert. Wegen der hohen Kern- und Hüllenspins I=5/2, J=4 ergeben sich 54 Zeemanzustände und ein komplexes optisches Spektrum.Etwa 10^6 Ionen der beiden stabilen Isotope 151,153Eu+ werden in einer Penningfalle beieinem Magnetfeld von ca. 1.5T gespeichert. Durch Puffergas und Anregung einer Seitenbandfrequenzder Ionenbewegung wird optisches Pumpen in metastabile D-Zustände bei gleichzeitiger Kühlung der Ionenwolke verhindert.Bei Verstimmung eines frequenzverdoppelten Ti:Sa-Lasers wurde die Ionenfluoreszenz aufgenommen. Durch die Simulation der optischen Spektren gelang es, einzelne Übergänge des Isotopes 151Eu+ zu identifizieren. Mit Laser/Mikrowellen-Doppelresonanzmessungen erhält man ein in erster Ordnung dopplerfreies Mikrowellenspektren eines Überganges zwischen zwei Zeemanzuständen im Grundzustand.Durch Messung der Übergangsfrequenzen von insgesamt fünf Delta mI=+1 Übergängen und Bestimmung des Magnetfeldes durch Messung der Zyklotronfrequenz gespeicherter Elektronen konnte der gI-Faktor des Isotopes151Eu zu 151gI = 1.37734(6) bestimmt werden.
Resumo:
ABSTARCT Biotechnology has enabled the modification of agricultural materials in a very precise way. Crops have been modified through the insertion of new traits or the inhibition of existing gene functions, named Genetically Modified Organism (GMO), and resulted in improved tolerance of herbicide and/or increased resistance against pests, viruses and fungi. Commercial cultivation of GMO started in 1996 and increased rapidly in 2003 according to a recently released report by the International Service for the Acquisition of Agri-Biotech Applications (ISAAA), depicted continuing consumer resistance in Europe and other part of the world. Upon these developments, the European Union regulations mandated labeling of GMOs containing food and as a consequence, the labeling of GMO containing product in the case of exceeding the1% threshold of alien DNA is required. The aim of the study is to be able to detect and quantify the GMO from the mixture of natural food components. The surface plasmon resonance (SPR) technique combined with fluorescence was used for this purpose. During the presented studies, two key issues are addressed and tried to solve; what is the best strategy to design and built an interfacial architecture of a probe oligonucletide layer either on a two dimensional surface or on an array platform; and what is the best detection method allowing for a sensitive monitoring of the hybridisation events. The study includes two parts: first part includes characterization of different PNAs on a 2D planar surface by defining affinity constants using the very well established optical method “Surface Plasmon Fluorescence Spectroscopy”(SPFS) and on the array platform by “Surface Plasmon Fluorescence Microscopy” (SPFM), and at the end comparison of the sensitivity of these two techniques. The second part is composed of detection of alien DNA in food components by using DNA and PNA catcher probes on the array platform in real-time by SPFM.
Resumo:
Over the last three decades, sensors based on the phenomenon of surface plasmon resonance have proven particularly suitable for real time thin film characterization, gas detection, biomolecular interaction examination and to supplement electrochemical methods. Systems based on prism coupling have been combined with fluorescence detection under the name of surface plasmon fluorescence spectroscopy to increase sensitivity even further. Alternatively, metal gratings can be employed to match photons for plasmon resonance. The real time monitoring of binding reactions not yet been reported in the combination of fluorescence detection and grating coupling. Grating-based systems promise more competitive products, because of reduced operating costs, and offer benefits for device engineering. This thesis is comprised of a comprehensive study of the suitability of grating coupling for fluorescence based analyte detection. Fundamental properties of grating coupled surface plasmon fluorescence spectroscopy are described, as well as issues related to the commercial realization of the method. Several new experimental techniques are introduced and demonstrated in order to optimize performance in certain areas and improve upon capabilities in respect to prism-based systems. Holographically fabricated gratings are characterized by atomic force microscopy and optical methods, aided by simulations and profile parameters responsible for efficient coupling are analyzed. The directional emission of fluorophores immobilized on a grating surface is studied in detail, including the magnitude and geometry of the fluorescence emission pattern for different grating constants and polarizations. Additionally, the separation between the minimum of the reflected intensity and the maximum fluorescence excitation position is examined. One of the key requirements for the commercial feasibility of grating coupling is the cheap and faithful mass production of disposable samples from a given master grating. The replication of gratings is demonstrated by a simple hot embossing method with good reproducibility to address this matter. The in-situ fluorescence detection of analyte immobilization and affinity measurements using grating coupling are described for the first time. The physical factors related to the sensitivity of the technique are assessed and the lower limit of detection of the technique is determined for an exemplary assay. Particular attention is paid to the contribution of bulk fluorophores to the total signal in terms of magnitude and polarization of incident and emitted light. Emission from the bulk can be a limiting factor for experiments with certain assay formats. For that reason, a novel optical method, based on the modulation of both polarization and intensity of the incident beam, is introduced and demonstrated to be capable of eliminating this contribution.
Resumo:
The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.
Resumo:
Die transmembrane Potenzialdifferenz Δφm ist direkt mit der katalytischen Aktivität der Cytochrom c Oxidase (CcO) verknüpft. Die CcO ist das terminale Enzym (Komplex IV) in der Atmungskette der Mitochondrien. Das Enzym katalysiert die Reduktion von O2 zu 2 H2O. Dabei werden Elektronen vom natürlichen Substrat Cytochrom c zur CcO übertragen. Der Eleltronentransfer innerhalb der CcO ist an die Protonentranslokation über die Membran gekoppelt. Folglich bildet sich über der inneren Membrane der Mitochondrien eine Differenz in der Protonenkonzentration. Zusätzlich wird eine Potenzialdifferenz Δφm generiert.rnrnDas Transmembranpotenzial Δφm kann mit Hilfe der Fluoreszenzspektroskopie unter Einsatz eines potenzialemfindlichen Farbstoffs gemessen werden. Um quantitative Aussagen aus solchen Untersuchungen ableiten zu können, müssen zuvor Kalibrierungsmessungen am Membransystem durchgeführt werden.rnrnIn dieser Arbeit werden Kalibrierungsmessungen von Δφm in einer Modellmembrane mit inkorporiertem CcO vorgestellt. Dazu wurde ein biomimetisches Membransystem, die Proteinverankerte Doppelschicht (protein-tethered Bilayer Lipid Membrane, ptBLM), auf einem transparenten, leitfähigem Substrat (Indiumzinnoxid, ITO) entwickelt. ITO ermöglicht den simultanen Einsatz von elektrochemischen und Fluoreszenz- oder optischen wellenleiterspektroskopischen Methoden. Das Δφm in der ptBLM wurde durch extern angelegte, definierte elektrische Spannungen induziert. rnrnEine dünne Hydrogelschicht wurde als "soft cushion" für die ptBLM auf ITO eingesetzt. Das Polymernetzwerk enthält die NTA Funktionsgruppen zur orientierten Immobilisierung der CcO auf der Oberfläche der Hydrogels mit Hilfe der Ni-NTA Technik. Die ptBLM wurde nach der Immobilisierung der CcO mittels in-situ Dialyse gebildet. Elektrochemische Impedanzmessungen zeigten einen hohen elektrischen Widerstand (≈ 1 MΩ) der ptBLM. Optische Wellenleiterspektren (SPR / OWS) zeigten eine erhöhte Anisotropie des Systems nach der Bildung der Doppellipidschicht. Cyklovoltammetriemessungen von reduziertem Cytochrom c bestätigten die Aktivität der CcO in der Hydrogel-gestützten ptBLM. Das Membranpotenzial in der Hydrogel-gestützten ptBLM, induziert durch definierte elektrische Spannungen, wurde mit Hilfe der ratiometrischen Fluoreszenzspektroskopie gemessen. Referenzmessungen mit einer einfach verankerten Dopplellipidschicht (tBLM) lieferten einen Umrechnungsfaktor zwischen dem ratiometrischen Parameter Rn und dem Membranpotenzial (0,05 / 100 mV). Die Nachweisgrenze für das Membranpotenzial in einer Hydrogel-gestützten ptBLM lag bei ≈ 80 mV. Diese Daten dienen als gute Grundlage für künftige Untersuchungen des selbstgenerierten Δφm der CcO in einer ptBLM.
Resumo:
Diese Arbeit befasst sich mit den optischen Resonanzen metallischer Nanopartikel im Abstand weniger Nanometer von einer metallischen Grenzfläche. Die elektromagnetische Wechselwirkung dieser „Kugel-vor-Fläche“ Geometrie ruft interessante optische Phänomene hervor. Sie erzeugt eine spezielle elektromagnetische Eigenmode, auch Spaltmode genannt, die im Wesentlichen auf den Nanospalt zwi-schen Kugel und Oberfläche lokalisiert ist. In der quasistatischen Näherung hängt die Resonanzposition nur vom Material, der Umgebung, dem Film-Kugel Abstand und dem Kugelradius selbst ab. Theoretische Berechnungen sagen für diese Region unter Resonanzbedingungen eine große Verstärkung des elektro-magnetischen Feldes voraus. rnUm die optischen Eigenschaften dieser Systeme zu untersuchen, wurde ein effizienter plasmonenver-mittelnder Dunkelfeldmodus für die konfokale Rastermikroskopie durch dünne Metallfilme entwickelt, der die Verstärkung durch Oberflächenplasmonen sowohl im Anregungs- als auch Emissionsprozess ausnutzt. Dadurch sind hochwertige Dunkelfeldaufnahmen durch die Metallfilme der Kugel-vor-Fläche Systeme garantiert, und die Spektroskopie einzelner Resonatoren wird erleichtert. Die optischen Untersuchungen werden durch eine Kombination von Rasterkraft- und Rasterelektronenmikroskopie vervollständigt, so dass die Form und Größe der untersuchten Resonatoren in allen drei Dimensionen bestimmt und mit den optischen Resonanzen korreliert werden können. Die Leistungsfähigkeit des neu entwickelten Modus wird für ein Referenzsystem aus Polystyrol-Kugeln auf einem Goldfilm demonstriert. Hierbei zeigen Partikel gleicher Größe auch die erwartete identische Resonanz.rnFür ein aus Gold bestehendes Kugel-vor-Fläche System, bei dem der Spalt durch eine selbstorganisierte Monolage von 2-Aminoethanthiol erzeugt wird, werden die Resonanzen von Goldpartikeln, die durch Reduktion mit Chlorgoldsäure erzeugt wurden, mit denen von idealen Goldkugeln verglichen. Diese ent-stehen aus den herkömmlichen Goldpartikeln durch zusätzliche Bestrahlung mit einem Pikosekunden Nd:Yag Laser. Bei den unbestrahlten Partikeln mit ihrer Unzahl an verschiedenen Formen zeigen nur ein Drittel der untersuchten Resonatoren ein Verhalten, das von der Theorie vorhergesagt wird, ohne das dies mit ihrer Form oder Größe korrelieren würde. Im Fall der bestrahlten Goldkugeln tritt eine spürbare Verbesserung ein, bei dem alle Resonatoren mit den theoretischen Rechnungen übereinstimmen. Eine Änderung der Oberflächenrauheit des Films zeigt hingegen keinen Einfluß auf die Resonanzen. Obwohl durch die Kombination von Goldkugeln und sehr glatten Metallfilmen eine sehr definierte Probengeometrie geschaffen wurde, sind die experimentell bestimmten Linienbreiten der Resonanzen immer noch wesentlich größer als die berechneten. Die Streuung der Daten, selbst für diese Proben, deutet auf weitere Faktoren hin, die die Spaltmoden beeinflußen, wie z.B. die genaue Form des Spalts. rnDie mit den Nanospalten verbundenen hohen Feldverstärkungen werden untersucht, indem ein mit Farbstoff beladenes Polyphenylen-Dendrimer in den Spalt eines aus Silber bestehenden Kugel-vor-Fläche Systems gebracht wird. Das Dendrimer in der Schale besteht lediglich aus Phenyl-Phenyl Bindungen und garantiert durch die damit einhergende Starrheit des Moleküls eine überragende Formstabiliät, ohne gleichzeitig optisch aktiv zu sein. Die 16 Dithiolan Endgruppen sorgen gleichzeitig für die notwendige Affinität zum Silber. Dadurch kann der im Inneren befindliche Farbstoff mit einer Präzision von wenigen Nanometern im Spalt zwischen den Metallstrukturen platziert werden. Der gewählte Perylen Farbstoff zeichnet sich wiederum durch hohe Photostabilität und Fluoreszenz-Quantenausbeute aus. Für alle untersuchten Partikel wird ein starkes Fluoreszenzsignal gefunden, das mindestens 1000-mal stärker ist, als das des mit Farbstoff überzogenen Metallfilms. Das Profil des Fluoreszenz-Anregungsspektrums variiert zwischen den Partikeln und zeigt im Vergleich zum freien Farbstoff eine zusätzliche Emission bei höheren Frequenzen, was in der Literatur als „hot luminescence“ bezeichnet wird. Bei der Untersuchung des Streuverhaltens der Resonatoren können wieder zwei unterschiedliche Arten von Resonatoren un-terschieden werden. Es gibt zunächst die Fälle, die bis auf die beschriebene Linienverbreiterung mit einer idealen Kugel-vor-Fläche Geometrie übereinstimmen und dann andere, die davon stark abweichen. Die Veränderungen der Fluoreszenz-Anregungsspektren für den gebundenen Farbstoffs weisen auf physikalische Mechanismen hin, die bei diesen kleinen Metall/Farbstoff Abständen eine Rolle spielen und die über eine einfache wellenlängenabhängige Verstärkung hinausgehen.
Resumo:
This thesis reports on the experimental realization of nanofiber-based spectroscopy of organic molecules. The light guided by subwavelength diameter optical nanfibers exhibits a pronounced evanescent field surrounding the fiber which yields high excitation and emission collection efficiencies for molecules on or near the fiber surface.rnThe optical nanofibers used for the experiments presented in this thesis are realized as thernsub-wavelength diameter waist of a tapered optical fiber (TOF). The efficient transfer of thernlight from the nanofiber waist to the unprocessed part of the TOF depends critically on therngeometric shape of the TOF transitions which represent a nonuniformity of the TOF. Thisrnnonuniformity can cause losses due to coupling of the fundamental guided mode to otherrnmodes which are not guided by the taper over its whole length. In order to quantify the lossrnfrom the fundamental mode due to tapering, I have solved the coupled local mode equationsrnin the approximation of weak guidance for the three layer system consisting of fiber core andrncladding as well as the surrounding vacuum or air, assuming the taper shape of the TOFsrnused for the experiments presented in this thesis. Moreover, I have empirically studied therninfluence of the TOF geometry on its transmission spectra and, based on the results, I haverndesigned a nanofiber-waist TOF with broadband transmission for experiments with organicrnmolecules.rnAs an experimental demonstration of the high sensitivity of nanofiber-based surface spectroscopy, I have performed various absorption and fluorescence spectroscopy measurements on the model system 3,4,9,10-perylene-tetracarboxylic dianhydride (PTCDA). The measured homogeneous and inhomogeneous broadening of the spectra due to the interaction of the dielectric surface of the nanofiber with the surface-adsorbed molecules agrees well with the values theoretically expected and typical for molecules on surfaces. Furthermore, the self-absorption effects due to reasorption of the emitted fluorescence light by circumjacent surface-adsorbed molecules distributed along the fiber waist have been analyzed and quantified. With time-resolved measurements, the reorganization of PTCDA molecules to crystalline films and excimers can be observed and shown to be strongly catalyzed by the presence of water on the nanofiber surface. Moreover, the formation of charge-transfer complexes due to the interaction with localized surface defects has been studied. The collection efficiency of the molecular emission by the guided fiber mode has been determined by interlaced measurements of absorption and fluorescence spectra to be about 10% in one direction of the fiber.rnThe high emission collection efficiency makes optical nanofibers a well-suited tool for experiments with dye molecules embedded in small organic crystals. As a first experimental realization of this approach, terrylene-doped para-terphenyl crystals attached to the nanofiber-waist of a TOF have been studied at cryogenic temperatures via fluorescence and fluorescence excitation spectroscopy. The statistical fine structure of the fluorescence excitation spectrum for a specific sample has been observed and used to give an estimate of down to 9 molecules with center frequencies within one homogeneous width of the laser wavelength on average for large detunings from resonance. The homogeneous linewidth of the transition could be estimated to be about 190MHz at 4.5K.