4 resultados para PULSE SEQUENCES

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Functional materials have great importance due to their many important applications. The characterization of supramolecular architectures which are held together by non-covalent interactions is of most importance to understand their properties. Solid-state NMR methods have recently been proven to be able to unravel such structure-property relations with the help of fast magic-angle spinning and advanced pulse sequences. The aim of the current work is to understand the structure and dynamics of functional supramolecular materials which are potentially important for fuel-cell (proton conducting membrane materials) and solar-cell or plastic-electronic applications (photo-reactive aromatic materials). In particular, hydrogen-bonding networks, local proton mobility, molecular packing arrangements, and local dynamics will be studied by the use of advanced solid-state NMR methods. The first class of materials studied in this work is proton conducting polymers which also form hydrogen-bonding network. Different materials, which are prepared for high 1H conduction by different approaches are studied: PAA-P4VP, PVPA-ABPBI, Tz5Si, and Triazole-functional systems. The materials are examples of the following major groups; - Homopolymers with specific functional groups (Triazole functional polysiloxanes). - Acid-base polymer blends approach (PAA-P4VP, PVPA-ABPBI). - Acid-base copolymer approach (Triazole-PVPA). - Acid doped polymers (Triazole functional polymer doped with H3PO4). Perylenebisimide (PBI) derivatives, a second type of important functional supramolecular materials with potent applications in plastic electronics, were also investigated by means of solid-state NMR. The preparation of conducting nanoscopic fibers based on the self-assembling functional units is an appealing aim as they may be incorporated in molecular electronic devices. In this category, perylene derivatives have attracted great attention due to their high charge carrier mobility. A detailed knowledge about their supramolecular structure and molecular dynamics is crucial for the understanding of their electronic properties. The aim is to understand the structure, dynamics and packing arrangements which lead to high electron conductivity in PBI derivatives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for 1H, the most widely used nucleus in NMR andrnMRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones.Here, I describe a method giving rise to high 1H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences.rnrnHyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization.These two achievements open up alternative opportunities to use the standard MRI nucleus 1H for e.g. metabolic imaging in the future.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hyperpolarization techniques enhance the nuclear spin polarization and thus allow for new nuclear magnetic resonance applications like in vivo metabolic imaging. One of these techniques is Parahydrogen Induced Polarization (PHIP). It leads to a hyperpolarized 1H spin state which can be transferred to a heteronucleus like 13C by a radiofrequency (RF) pulse sequence. In this work, timing of such a sequence was analyzed and optimized for the molecule hydroxyethyl propionate. The pulse sequence was adapted for the work on a clinical magnetic resonance imaging (MRI) system which is usually equipped only with a single RF transmit channel. Optimal control theory optimizations were performed to achieve an optimized polarization transfer. A drawback of hyperpolarization is its limited lifetime due to relaxation processes. The lifetime can be increased by storing the hyperpolarization in a spin singlet state. The second part of this work therefore addresses the spin singlet state of the Cs-symmetric molecule dimethyl maleate which needs to be converted to the spin triplet state to be detectable. This conversion was realized on a clinical MRI system, both by field cycling and by two RF pulse sequences which were adapted and optimized for this purpose. Using multiple conversions enables the determination of the lifetime of the singlet state as well as the conversion efficiency of the RF pulse sequence. Both, the hyperpolarized 13C spin state and the converted singlet state were utilized for MR imaging. Careful choice of the echo time was shown to be crucial for both molecules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die rasante Entwicklung der Computerindustrie durch die stetige Verkleinerung der Transistoren führt immer schneller zum Erreichen der Grenze der Si-Technologie, ab der die Tunnelprozesse in den Transistoren ihre weitere Verkleinerung und Erhöhung ihrer Dichte in den Prozessoren nicht mehr zulassen. Die Zukunft der Computertechnologie liegt in der Verarbeitung der Quanteninformation. Für die Entwicklung von Quantencomputern ist die Detektion und gezielte Manipulation einzelner Spins in Festkörpern von größter Bedeutung. Die Standardmethoden der Spindetektion, wie ESR, erlauben jedoch nur die Detektion von Spinensembles. Die Idee, die das Auslesen von einzelnen Spins ermöglich sollte, besteht darin, die Manipulation getrennt von der Detektion auszuführen.rn Bei dem NV−-Zentrum handelt es sich um eine spezielle Gitterfehlstelle im Diamant, die sich als einen atomaren, optisch auslesbaren Magnetfeldsensor benutzen lässt. Durch die Messung seiner Fluoreszenz sollte es möglich sein die Manipulation anderer, optisch nicht detektierbaren, “Dunkelspins“ in unmittelbarer Nähe des NV-Zentrums mittels der Spin-Spin-Kopplung zu detektieren. Das vorgeschlagene Modell des Quantencomputers basiert auf dem in SWCNT eingeschlossenen N@C60.Die Peapods, wie die Einheiten aus den in Kohlenstoffnanoröhre gepackten Fullerenen mit eingefangenem Stickstoff genannt werden, sollen die Grundlage für die Recheneinheiten eines wahren skalierbaren Quantencomputers bilden. Die in ihnen mit dem Stickstoff-Elektronenspin durchgeführten Rechnungen sollen mit den oberflächennahen NV-Zentren (von Diamantplatten), über denen sie positioniert sein sollen, optisch ausgelesen werden.rnrnDie vorliegende Arbeit hatte das primäre Ziel, die Kopplung der oberflächennahen NV-Einzelzentren an die optisch nicht detektierbaren Spins der Radikal-Moleküle auf der Diamantoberfläche mittels der ODMR-Kopplungsexperimente optisch zu detektieren und damit entscheidende Schritte auf dem Wege der Realisierung eines Quantenregisters zu tun.rn Es wurde ein sich im Entwicklungsstadium befindende ODMR-Setup wieder aufgebaut und seine bisherige Funktionsweise wurde an kommerziellen NV-Zentrum-reichen Nanodiamanten verifiziert. Im nächsten Schritt wurde die Effektivität und Weise der Messung an die Detektion und Manipulation der oberflächennah (< 7 nm Tiefe) implantieren NV-Einzelzenten in Diamantplatten angepasst.Ein sehr großer Teil der Arbeit, der hier nur bedingt beschrieben werden kann, bestand aus derrnAnpassung der existierenden Steuersoftware an die Problematik der praktischen Messung. Anschließend wurde die korrekte Funktion aller implementierten Pulssequenzen und anderer Software-Verbesserungen durch die Messung an oberflächennah implantierten NV-Einzelzentren verifiziert. Auch wurde der Messplatz um die zur Messung der Doppelresonanz notwendigen Komponenten wie einen steuerbaren Elektromagneten und RF-Signalquelle erweitert. Unter der Berücksichtigung der thermischen Stabilität von N@C60 wurde für zukünftige Experimente auch ein optischer Kryostat geplant, gebaut, in das Setup integriert und charakterisiert.rn Die Spin-Spin-Kopplungsexperimente wurden mit dem sauerstoffstabilen Galvinoxyl-Radikalals einem Modell-System für Kopplung durchgeführt. Dabei wurde über die Kopplung mit einem NVZentrum das RF-Spektrum des gekoppelten Radikal-Spins beobachtet. Auch konnte von dem gekoppelten Spin eine Rabi-Nutation aufgenommen werden.rn Es wurden auch weitere Aspekte der Peapod Messung und Oberflächenimplantation betrachtet.Es wurde untersucht, ob sich die NV-Detektion durch die SWCNTs, Peapods oder Fullerene stören lässt. Es zeigte sich, dass die Komponenten des geplanten Quantencomputers, bis auf die C60-Cluster, für eine ODMR-Messanordnung nicht detektierbar sind und die NV-Messung nicht stören werden. Es wurde auch betrachtet, welche Arten von kommerziellen Diamantplatten für die Oberflächenimplantation geeignet sind, für die Kopplungsmessungen geeignete Dichte der implantierten NV-Zentren abgeschätzt und eine Implantation mit abgeschätzter Dichte betrachtet.