4 resultados para Measurements models
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of ß-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A = 90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-fligh ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ< 1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported.
Resumo:
Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N~90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of 241-Am could be measured directly for the first time.
Resumo:
The biosphere emits copiously volatile organic compounds (VOCs) into the atmosphere, which are removed again depending on the oxidative capacity of the atmosphere and physical processes such as mixing, transport and deposition. Biogenic VOCs react with the primary oxidant of the atmosphere, the hydroxyl radical (OH), and potentially lead to the formation tropospheric ozone and aerosol, which impact regional climate and air quality. The rate of OH decay in the atmosphere, the total OH reactivity is a function of the atmospheric, reactive compound's concentration and reaction velocity with OH. One way to measure the total OH reactivity, the total OH sink, is with the Comparative Reactivity Method - CRM. Basically, the reaction of OH with a reagent (here pyrrole) in clean air and in the presence of atmospheric, reactive molecules is compared. This thesis presents measurements of the total OH reactivity at the biosphere-atmosphere interface to analyze various influences and driving forces. For measurements in natural environment the instrument was automated and a direct, undisturbed sampling method developed. Additionally, an alternative detection system was tested and compared to the originally used detector (Proton Transfer Reaction-Mass Spectrometer, PTR-MS). The GC-PID (Gas Chromatographic Photo-Ionization Detector) was found as a smaller, less expensive, and robust alternative for total OH reactivity measurements. The HUMPPA-COPEC 2010 measurement campaign in the Finish forest was impacted by normal boreal forest emissions as well as prolonged heat and biomass burning emissions. The measurement of total OH reactivity was compared with a comprehensive set of monitored individual species ambient concentration levels. A significant discrepancy between those individually measured OH sinks and the total OH reactivity was observed, which was characterized in detail by the comparison of within and above the forest canopy detected OH reactivity. Direct impact of biogenic emissions on total OH reactivity was examined on Kleiner Feldberg, Germany, 2011. Trans-seasonal measurements of an enclosed Norway spruce branch were conducted via PTR-MS, for individual compound's emission rates, and CRM, for total OH reactivity emission fluxes. Especially during summertime, the individually monitored OH sink terms could not account for the measured total OH reactivity. A controlled oxidation experiment in a low NOx environment was conducted in the EUPHORE reaction chamber (CHEERS, Spain 2011). The concentration levels of the reactant isoprene and its major products were monitored and compared to total OH reactivity measurements as well as to the results of two models. The individually measured compounds could account for the total OH reactivity during this experiment as well as the traditional model-degradation scheme for isoprene (MCM 3.2). Due to previous observations of high OH levels in the isoprene-rich environment of the tropics, a novel isoprene mechanism was recently suggested. In this mechanism (MIME v4) additional OH is generated during isoprene oxidation, which could not be verified in the conditions of the CHEERS experiment.
Resumo:
RNAi ist ein bedeutendes Werkzeug zur Funktionsanalyse von Genen und hat großes Potential für den Einsatz in der Therapie. Obwohl effiziente Knockdowns in der Zellkultur erzielt werden, erweist sich eine in vivo Anwendung als schwierig. Die großen Hürden sind dabei der Transport der siRNA ins Zielgewebe und deren voranschreitende Degradierung.rnMarkierte siRNA kann sowohl zur eigenen Integritätsmessung als auch zur Lokalisierung verwendet werden. Zwei Farbstoffe an den jeweiligen 3’- bzw. -5’-Enden des Sense- bzw. Antisense-Stranges erzeugen ein robustes FRET-System (Hirsch et al. 2012). Das Verhältnis von FRET- zu Donor-Signal, das R/G-Ratio, dient zur sensitiven Klassifizierung des Integritätslevels einer siRNA Probe (Järve et al. 2007; Hirsch et al. 2011; Kim et al. 2010). Mit diesem System kann eine Degradierung von weniger als 5 % in der Küvette und in Zellen nachgewiesen werden.rnDie vorliegende Arbeit beschäftigt sich mit der Evaluierung von potentiellen FRET Farbstoffpaaren hinsichtlich deren Eignung für in vitro und in vivo Anwendung. Verschiedenste FRET-Paare, die das gesamte sichtbare Spektrum abdecken, wurden evaluiert und ermöglichen nun die Auswahl eines geeigneten Paares für die jeweilige Anwendung oder Kombination mit anderen Farbstoffen.rnMit Hilfe von Alexa555/Atto647N siRNA wurde ein erfolgreicher Einschluss von siRNA in Liposomen beobachtet. Eine anschließende Evaluierung der RNase-Protektion ergab für Liposomen, Nanohydrogele und kationische Peptide hervorragende protektive Eigenschaften. Basierend auf den Ergebnisse können diese und andere Transportsysteme nun für eine zelluläre Aufnahme optimiert werden.rnAtto488/Atto590 zeigte die besten Eigenschaften für Echtzeit-Integritätsmessungen in der Lebendzellmikroskopie. Verringerte Bleicheigenschaften und minimaler spektraler “Cross-Talk” ermöglichten es, transfizierte Zellen über einen Zeitraum von bis zu 8 Stunden zu beobachten. Mittels Atto488/Atto590 siRNA wurde die Einschleusung und Freisetzung in Zellen in Echtzeit untersucht. Dabei konnten Freisetzung und Verteilung in einzelnen Zellen beobachtet und analysiert werden. rnAuf eine anfängliche Phase mit hoher Freisetzungsrate folgte eine Phase mit geringerer Rate für den restlichen Beobachtungszeitraum. Die durchschnittliche Verweildauer im Zytosol betrug 24 und 58 Minuten, wobei zwischen lang- und kurzanhaltenden Ereignissen unterschieden werden konnte. Obwohl ein Import von siRNA in den Zellkern beobachtet wurde, konnte kein Schema bzw. genauer Zeitpunkt, in Bezug auf den Transfektionszeitraum für diese Ereignisse bestimmt werden. Die beobachteten Freisetzungsprozesse fanden sporadisch statt und Änderungen in der zellulären Verteilung geschahen innerhalb von wenigen Minuten. Einmal freigesetzte siRNA verschwand mit der Zeit wieder aus dem Zytosol und es blieben nur kleine Aggregate von siRNA mit immer noch geringer Integrität zurück.rn