2 resultados para Mass flow rates
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
A one-dimensional multi-component reactive fluid transport algorithm, 1DREACT (Steefel, 1993) was used to investigate different fluid-rock interaction systems. A major short coming of mass transport calculations which include mineral reactions is that solid solutions occurring in many minerals are not treated adequately. Since many thermodynamic models of solid solutions are highly non-linear, this can seriously impact on the stability and efficiency of the solution algorithms used. Phase petrology community saw itself faced with a similar predicament 10 years ago. To improve performance and reliability, phase equilibrium calculations have been using pseudo compounds. The same approach is used here in the first, using the complex plagioclase solid solution as an example. Thermodynamic properties of a varying number of intermediate plagioclase phases were calculated using ideal molecular, Al-avoidance, and non-ideal mixing models. These different mixing models can easily be incorporated into the simulations without modification of the transport code. Simulation results show that as few as nine intermediate compositions are sufficient to characterize the diffusional profile between albite and anorthite. Hence this approach is very efficient, and can be used with little effort. A subsequent chapter reports the results of reactive fluid transport modeling designed to constrain the hydrothermal alteration of Paleoproterozoic sediments of the Southern Lake Superior region. Field observations reveal that quartz-pyrophyllite (or kaolinite) bearing assemblages have been transformed into muscovite-pyrophyllite-diaspore bearing assemblages due to action of fluids migrating along permeable flow channels. Fluid-rock interaction modeling with an initial qtz-prl assemblage and a K-rich fluid simulates the formation of observed mineralogical transformation. The bulk composition of the system evolves from an SiO2-rich one to an Al2O3+K2O-rich one. Simulations show that the fluid flow was up-temperature (e.g. recharge) and that fluid was K-rich. Pseudo compound approach to include solid solutions in reactive transport models was tested in modeling hydrothermal alteration of Icelandic basalts. Solid solutions of chlorites, amphiboles and plagioclase were included as the secondary mineral phases. Saline and fresh water compositions of geothermal fluids were used to investigate the effect of salinity on alteration. Fluid-rock interaction simulations produce the observed mineral transformations. They show that roughly the same alteration minerals are formed due to reactions with both types of fluid which is in agreement with the field observations. A final application is directed towards the remediation of nitrate rich groundwaters. Removal of excess nitrate from groundwater by pyrite oxidation was modeled using the reactive fluid transport algorithm. Model results show that, when a pyrite-bearing, permeable zone is placed in the flow path, nitrate concentration in infiltrating water can be significantly lowered, in agreement with proposals from the literature. This is due to nitrogen reduction. Several simulations investigate the efficiency of systems with different mineral reactive surface areas, reactive barrier zone widths, and flow rates to identify the optimum setup.
Resumo:
In dieser Arbeit wird das Konzept eines aktiven Pulverinhalators entwickelt. Im Gegensatz zu einem passiven Pulverinhalator ist bei solch einem Gerät die Abgabe und Dispergierung der Arzneistoffformulierung nicht von einem Inhalationsmanöver abhängig, welches von Patient zu Patient variiert. Solch ein System würde folglich die Zuverlässigkeit und Effizienz der inhalativen Therapie verbessern. Mögliche Anwendungen für einen aktiven Pulverinhalator wären vor allem Indikationen, die die Abgabe hoher Dosen erfordern, wie z.B. in der Therapie mit Antibiotika.rnIn einem Designprozess, der alle aus Kundenwünschen ermittelten Konstruktionsanforderungen sammelt und verschiedene Lösungsansätze vergleicht, wird ein mit Treibgas betriebener atemzugsausgelöster, Mehrfach-Dosis Pulverinhalator als aussichtsreichstes Konzept ermittelt. Dieses Konzept wird in Form von eigens konstruierten Labor-Test-Rigs entwickelt und vor allem hinsichtlich Höhe der Dosierung, Dosiergenauigkeit, und Flussratenabhängigkeit evaluiert. In der Spitze können über 16 mg lungengängiger Dosis erreicht werden, bei im Vergleich zu dem eingesetzten passiven Inhalator mindestens nur halb so großer Streuung. Bei niedrigen Flussraten können immer noch bis zu 80 % der erzielten inhalierbaren Dosis von hohen Flussraten erreicht werden und damit die Ergebnisse des passiven Inhalators deutlich übertreffen.rnTeil der Aufgabe war es, dieses treibgasbetriebene Labor-Test-Rig so zu entwickeln, dass es implementierbar in einen atemzugsausgelösten Mehrfachdosis-Pulverinhalator ist. Dieser treibgasbetriebene, atemzugsausgelöste Mehrfachdosis-Pulverinhalator würde die Kundenwünsche und Konstruktionsanforderungen in sehr hohen Maße erfüllen, so dass hier die Möglichkeit besteht einen Inhalator mit sehr hohem Grad an Patienten-Compliance zu verwirklichen. Durch die Verwendung und Neukombination bereits etablierter Technologien und einen akzeptablen Stückkostenpreis besteht die Möglichkeit den Inhalator tatsächlich zu realisieren und zu vermarkten.