2 resultados para London (Watford) Spring-Water Company.

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many of developing countries are facing crisis in water management due to increasing of population, water scarcity, water contaminations and effects of world economic crisis. Water distribution systems in developing countries are facing many challenges of efficient repair and rehabilitation since the information of water network is very limited, which makes the rehabilitation assessment plans very difficult. Sufficient information with high technology in developed countries makes the assessment for rehabilitation easy. Developing countries have many difficulties to assess the water network causing system failure, deterioration of mains and bad water quality in the network due to pipe corrosion and deterioration. The limited information brought into focus the urgent need to develop economical assessment for rehabilitation of water distribution systems adapted to water utilities. Gaza Strip is subject to a first case study, suffering from severe shortage in the water supply and environmental problems and contamination of underground water resources. This research focuses on improvement of water supply network to reduce the water losses in water network based on limited database using techniques of ArcGIS and commercial water network software (WaterCAD). A new approach for rehabilitation water pipes has been presented in Gaza city case study. Integrated rehabilitation assessment model has been developed for rehabilitation water pipes including three components; hydraulic assessment model, Physical assessment model and Structural assessment model. WaterCAD model has been developed with integrated in ArcGIS to produce the hydraulic assessment model for water network. The model have been designed based on pipe condition assessment with 100 score points as a maximum points for pipe condition. As results from this model, we can indicate that 40% of water pipeline have score points less than 50 points and about 10% of total pipes length have less than 30 score points. By using this model, the rehabilitation plans for each region in Gaza city can be achieved based on available budget and condition of pipes. The second case study is Kuala Lumpur Case from semi-developed countries, which has been used to develop an approach to improve the water network under crucial conditions using, advanced statistical and GIS techniques. Kuala Lumpur (KL) has water losses about 40% and high failure rate, which make severe problem. This case can represent cases in South Asia countries. Kuala Lumpur faced big challenges to reduce the water losses in water network during last 5 years. One of these challenges is high deterioration of asbestos cement (AC) pipes. They need to replace more than 6500 km of AC pipes, which need a huge budget to be achieved. Asbestos cement is subject to deterioration due to various chemical processes that either leach out the cement material or penetrate the concrete to form products that weaken the cement matrix. This case presents an approach for geo-statistical model for modelling pipe failures in a water distribution network. Database of Syabas Company (Kuala Lumpur water company) has been used in developing the model. The statistical models have been calibrated, verified and used to predict failures for both networks and individual pipes. The mathematical formulation developed for failure frequency in Kuala Lumpur was based on different pipeline characteristics, reflecting several factors such as pipe diameter, length, pressure and failure history. Generalized linear model have been applied to predict pipe failures based on District Meter Zone (DMZ) and individual pipe levels. Based on Kuala Lumpur case study, several outputs and implications have been achieved. Correlations between spatial and temporal intervals of pipe failures also have been done using ArcGIS software. Water Pipe Assessment Model (WPAM) has been developed using the analysis of historical pipe failure in Kuala Lumpur which prioritizing the pipe rehabilitation candidates based on ranking system. Frankfurt Water Network in Germany is the third main case study. This case makes an overview for Survival analysis and neural network methods used in water network. Rehabilitation strategies of water pipes have been developed for Frankfurt water network in cooperation with Mainova (Frankfurt Water Company). This thesis also presents a methodology of technical condition assessment of plastic pipes based on simple analysis. This thesis aims to make contribution to improve the prediction of pipe failures in water networks using Geographic Information System (GIS) and Decision Support System (DSS). The output from the technical condition assessment model can be used to estimate future budget needs for rehabilitation and to define pipes with high priority for replacement based on poor condition. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen der vorliegenden Arbeit wurden zum ersten Mal kalorimetrische Tieftemperatur-Detektoren in der Beschleuniger-Massenspektrometrie (Accelerator Mass Spectrometry AMS), einer Standard-Methode zur Bestimmung kleinster Isotopenverhältnisse, eingesetzt, um das Isotopenverhältnis von 236U zu 238U zu bestimmen. Das Uran-Isotop 236U entsteht in der Neutroneneinfang-Reaktion 235U(n,gamma)236U und kann daher als Monitor-Nuklid für Neutronenflüsse verwendet werden. Die Detektoren bestehen aus einem Saphir-Absorber, auf den ein supraleitender Aluminium-Film aufgedampft ist, der als Thermistor dient. Ein energetisches Schwerion deponiert seine kinetische Energie als Wärme im Absorber, dessen Temperaturänderung durch die Widerstandsänderung des Supraleiters nachgewiesen wird. Mit solchen Detektoren konnte in vorhergehenden Experimenten bei GSI in einem Energiebereich von E = 5 - 300 MeV/amu für eine Vielzahl von Ionen von Neon bis Uran eine relative Energieauflösung von (1 - 4) E-3 erreicht werden. Der für die Beschleuniger-Massenspektrometrie typische Energiebereich liegt bei E = 0.1 - 1 MeV/amu. Im ersten Schritt wurde daher die systematische Untersuchung der Detektoreigenschaften auf diesen Energiebereich ausgedehnt. Diese Untersuchungen sowie die AMS-Messungen wurden am Tandem-Beschleuniger VERA des Instituts für Isotopenforschung und Kernphysik der Universität Wien durchgeführt. In einem Energiebereich von 10 - 60 MeV konnte für verschiedene Ionen (13C, 197Au, 238U) zunächst eine relative Energieauflösung von DeltaE/E = 7 E-3 erreicht werden. Dies übertrifft die Auflösung konventioneller Ionisations-Detektoren um ca. eine Größenordnung. Durch eine Verbesserung thermischer und elektronischer Rauschbeiträge konnte in einem zweiten Experiment für Uran der Energie 17 MeV die Auflösung auf DeltaE/E = 4.6 E-3 verbessert werden. Die Energie-Response des Detektors war linear über den gesamten beobachteten Energiebereich und unabhängig von der Ionenmasse; bis auf ein Niveau von 0.1 % wurde kein Pulshöhendefekt beobachtet. Diese Ergebnisse zeigen, daß solche Detektoren ein wertvolles Werkzeug in der Schwerionenphysik im Bereich relativ niedriger Ionenenergien darstellen. Mit der erreichten Energieauflösung war es möglich, für mehrere Proben aus natürlichem Uran das Isotopenverhältnis 236U/238U zu bestimmen: Um einen Material-Standard für Uran in der AMS zu etablieren, wurde das Isotopenverhältnis 236U/238U für zwei Proben aus der Mine ''K.u.K. Joachimsthal'' möglichst präzise bestimmt. Die Ergebnisse in der vorliegenden Arbeit stimmen gut mit früheren Messungen überein, die mit einem konventionellen Detektorsystem durchgeführt wurden. Sowohl der statistische als auch der systematische Fehler konnten deutlich reduziert werden. Für eine weitere Probe, extrahiert aus dem Wasser einer Uran-haltigen Quelle in Bad Gastein, wurde ein Isotopenverhältnis von 6.1 E-12 gemessen. Dies stellt das kleinste bislang für 236U/238U gemessene Isotopenverhältnis dar und bedeutet eine Steigerung der Sensitivität um eine Größenordnung. Die erreichte Energieauflösung ermöglicht es außerdem, die Detektoren zur direkten Massenidentifikation von schweren Ionen mittels einer kombinierten Energie-Flugzeit-Messung einzusetzen. In ersten Test-Messungen im Rahmen der vorliegenden Arbeit wurde eine Massenauflösung von DeltaM/M = (8.5 - 11.0) E-3 erreicht. In einem ersten Test für den Einsatz dieser Detektoren zum Nachweis sog. ''superschwerer Elemente (Z >= 112)'' erlaubte der große dynamische Bereich, die Reaktionsprodukte und ihre nachfolgenden Alpha-Zerfälle mit hoher Energieauflösung simultan und zeitaufgelöst nachzuweisen.