3 resultados para Instrumental analysis
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
ABSTRACT One of the major ecological challenges on Lake Victoria resources is the existence of “hot spots”, caused by human waste, urban runoff, and industrial effluents. The lake is tending towards eutrophication which is attributed to the increasing human population in its watershed. A report of the levels of perfluorooctane sulfonate and perfluorooctanoic acid in environmental matrices of Lake Victoria is presented, and the management implication of perfluorinated compounds and similar potential organic pollutants examined. Two widely consumed and economically important fish species namely Lates niloticus (Nile perch) and Oreochromis niloticus (Nile tilapia) were obtained from Winam gulf of Lake Victoria, Kenya, and analysed for perfluorooctane sulfonate and perfluorooctanoic acid in muscles and liver using liquid chromatography coupled with mass spectroscopy. Variability in the concentrations of perfluorooctanoic acid or perfluorooctane sulfonate in river waters (range perfluorooctanoic acid 0.4 – 96.4 ng/L and perfluorooctane sulfonate < 0.4 – 13.2 ng/L) was higher than for Lake waters (range perfluorooctanoic acid 0.4 – 11.7 ng/L and perfluorooctane sulfonate < 0.4 – 2.5 ng/L respectively). Significant correlations were tested between perfluorinated compounds levels in sediments, fish and water. Wastewater treatment plants and other anthropogenic sources have been identified as significant sources or pathways for the introduction of perfluoroalkyl compounds into Lake Victoria ecosystem. In this study, elevated concentrations of perfluorooctanoic acid and perfluorooctane sulfonate was found in two wastewater treatment plants (WWTPs) in Kisumu, City of Kenya. An alternative analytical method to liquid chromatography/ mass spectroscopy for analysis of perfluorocarboxylic acids in abiotic and biotic matrices where high concentrations are expected is also presented. Derivatisation of the acid group to form a suitable alkyl ester provided a suitable compound for mass spectroscopy detection coupled to gas chromatography instrumental analysis. The acid is esterified by an alkyl halide i.e benzyl bromide as the alkylating agent for Perfluorocarboxylic acids quantification. The study also involved degradability measurements of emerging perfluorinated surfactants substitutes. The stability of the substitutes of perfluorinated surfactants was tested by employing advanced oxidation processes, followed by conventional tests, among them an automated method based on the manometric respirometry test and standardized fix bed bioreactor [FBBR] on perfluorobutane sulfonate (PFBS), a fluoroethylene polymer, fluorosurfactant (Zonyl), two fluoraliphaticesters (NOVEC ™ FC4430 and NOVEC ™ FC4432) and 10-(trifluoromethoxy) decane-sulfonate. Most of these emmerging surfactants are well-established in the market and have been used in several applications as alternatives to PFOS and PFOA based surfactants. The results of this study can be used as pioneer information for further studies on the sources, behaviour and fate of PFOA and PFOS and other related compounds in both abiotic and biota compartments of Lake Victoria and other lakes. Further an overview in degradation of emerging perfluorinated compounds substitutes is presented. Contribution in method development especially for acid group based fluorosurfactants is presented. The data obtained in this study can particularly be considered when formulating policies and management measures for preservation and sustainability of Lake Victoria resources.
Resumo:
A new method to measure the sulfur isotopic composition of individual aerosol particles by NanoSIMS has been developed and tested on several standards such as barite (BaSO4), anhydrite (CaSO4), gypsum (CaSO4·2H2O), mascagnite ((NH4)2SO4), epsomite (MgSO4·7H2O), magnesium sulfate (MgSO4·xH2O), thenardite (Na2SO4), boetite (K2SO4) and cysteine (an amino acid). This ion microprobe technique employs a Cs+ primary ion beam and measures negative secondary ions permitting the analysis of sulfur isotope ratios in individual aerosol particles down to 500 nm in size (0.001-0.5 ng of sample material). The grain-to-grain reproducibility of measurements is typically 5‰ (1σ) for micron-sized grains, <5‰ for submicron-sized grains, and <2‰ for polished thin sections and ultra microtome sections which were studied for comparison. The role of chemical omposition (matrix effect) and sample preparation techniques on the instrumental mass fractionation (IMF) of the 34S/32S ratio in the NanoSIMS has been investigated. The IMF varies by ~15‰ between the standards studied here. A good correlation between IMF and ionic radius of the cations in sulfates was observed. This permits to infer IMF corrections even for sulfates for which no isotope standards are available. The new technique allows to identify different types of primary and secondary sulfates based on their chemical composition and to measure their isotopic signature separately. It was applied to marine aerosol samples collected in Mace Head and urban aerosol samples collected in Mainz. It was shown that primary sulfate particles such as sulfate in NaCl or gypsum particles precipitated from ocean water retain the original isotopic signature of their source. The isotopic composition of secondary sulfate depends on the isotopic composition of precursor SO2 and the oxidation pathway. The 34S/32S fractionation with respect to the precursor SO2 is -9‰ for homogeneous oxidation and +16.5‰ for heterogeneous oxidation. This large difference between the isotopic fractionation of both pathways allows identifying the oxidation pathway from which the SO42- in a secondary sulfate particle is derived, by means of its sulfur isotope ratio, provided that the isotopic signature of the precursor SO2 is known. The isotopic composition of the precursor SO2 of secondary sulfates was calculated based on the isotopic composition of particles with known oxidation pathway such as fine mode ammonium sulfate.
Resumo:
Der atmosphärische Kreislauf reaktiver Stickstoffverbindungen beschäftigt sowohl die Naturwissenschaftler als auch die Politik. Dies ist insbesondere darauf zurückzuführen, dass reaktive Stickoxide die Bildung von bodennahem Ozon kontrollieren. Reaktive Stickstoffverbindungen spielen darüber hinaus als gasförmige Vorläufer von Feinstaubpartikeln eine wichtige Rolle und der Transport von reaktivem Stickstoff über lange Distanzen verändert den biogeochemischen Kohlenstoffkreislauf des Planeten, indem er entlegene Ökosysteme mit Stickstoff düngt. Die Messungen von stabilen Stickstoffisotopenverhältnissen (15N/14N) bietet ein Hilfsmittel, welches es erlaubt, die Quellen von reaktiven Stickstoffverbindungen zu identifizieren und die am Stickstoffkeislauf beteiligten Reaktionen mithilfe ihrer reaktionsspezifischen Isotopenfraktionierung genauer zu untersuchen. rnIn dieser Doktorarbeit demonstriere ich, dass es möglich ist, mit Hilfe von Nano-Sekundärionenmassenspektrometrie (NanoSIMS) verschiedene stickstoffhaltige Verbindungen, die üblicherweise in atmosphärischen Feinstaubpartikeln vorkommen, mit einer räumlichen Auflösung von weniger als einem Mikrometer zu analysieren und zu identifizieren. Die Unterscheidung verschiedener stickstoffhaltiger Verbindungen erfolgt anhand der relativen Signalintensitäten der positiven und negativen Sekundärionensignale, die beobachtet werden, wenn die Feinstaubproben mit einem Cs+ oder O- Primärionenstrahl beschossen werden. Die Feinstaubproben können direkt auf dem Probenahmesubstrat in das Massenspektrometer eingeführt werden, ohne chemisch oder physikalisch aufbereited zu werden. Die Methode wurde Mithilfe von Nitrat, Nitrit, Ammoniumsulfat, Harnstoff, Aminosären, biologischen Feinstaubproben (Pilzsporen) und Imidazol getestet. Ich habe gezeigt, dass NO2 Sekundärionen nur beim Beschuss von Nitrat und Nitrit (Salzen) mit positiven Primärionen entstehen, während NH4+ Sekundärionen nur beim Beschuss von Aminosäuren, Harnstoff und Ammoniumsalzen mit positiven Primärionen freigesetzt werden, nicht aber beim Beschuss biologischer Proben wie z.B. Pilzsporen. CN- Sekundärionen werden beim Beschuss aller stickstoffhaltigen Verbindungen mit positiven Primärionen beobachtet, da fast alle Proben oberflächennah mit Kohlenstoffspuren kontaminiert sind. Die relative Signalintensität der CN- Sekundärionen ist bei kohlenstoffhaltigen organischen Stickstoffverbindungen am höchsten.rnDarüber hinaus habe ich gezeigt, dass an reinen Nitratsalzproben (NaNO3 und KNO3), welche auf Goldfolien aufgebracht wurden speziesspezifische stabile Stickstoffisotopenverhältnisse mithilfe des 15N16O2- / 14N16O2- - Sekundärionenverhältnisses genau und richtig gemessen werden können. Die Messgenauigkeit auf Feldern mit einer Rastergröße von 5×5 µm2 wurde anhand von Langzeitmessungen an einem hausinternen NaNO3 Standard als ± 0.6 ‰ bestimmt. Die Differenz der matrixspezifischen instrumentellen Massenfraktionierung zwischen NaNO3 und KNO3 betrug 7.1 ± 0.9 ‰. 23Na12C2- Sekundärionen können eine ernst zu nehmende Interferenz darstellen wenn 15N16O2- Sekundärionen zur Messung des nitratspezifischen schweren Stickstoffs eingesetzt werden sollen und Natrium und Kohlenstoff im selben Feinstaubpartikel als interne Mischung vorliegt oder die natriumhaltige Probe auf einem kohlenstoffhaltigen Substrat abgelegt wurde. Selbst wenn, wie im Fall von KNO3, keine derartige Interferenz vorliegt, führt eine interne Mischung mit Kohlenstoff im selben Feinstaubpartikel zu einer matrixspezifischen instrumentellen Massenfraktionierung die mit der folgenden Gleichung beschrieben werden kann: 15Nbias = (101 ± 4) ∙ f − (101 ± 3) ‰, mit f = 14N16O2- / (14N16O2- + 12C14N-). rnWird das 12C15N- / 12C14N- Sekundärionenverhältnis zur Messung der stabilen Stickstoffisotopenzusammensetzung verwendet, beeinflusst die Probematrix die Messungsergebnisse nicht, auch wenn Stickstoff und Kohlenstoff in den Feinstaubpartikeln in variablen N/C–Verhältnissen vorliegen. Auch Interferenzen spielen keine Rolle. Um sicherzustellen, dass die Messung weiterhin spezifisch auf Nitratspezies eingeschränkt bleibt, kann eine 14N16O2- Maske bei der Datenauswertung verwendet werden. Werden die Proben auf einem kohlenstoffhaltigen, stickstofffreien Probennahmesubstrat gesammelt, erhöht dies die Signalintensität für reine Nitrat-Feinstaubpartikel.