8 resultados para Gear efficiency and gear selectivity

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diese Arbeit widmet sich der Untersuchung der photophysikalischen Prozesse, die in Mischungen von Elektronendonoren mit Elektronenakzeptoren zur Anwendung in organischen Solarzellen auftreten. Als Elektronendonoren werden das Copolymer PBDTTT-C, das aus Benzodithiophen- und Thienothiophene-Einheiten besteht, und das kleine Molekül p-DTS(FBTTh2)2, welches Silizium-überbrücktes Dithiophen, sowie fluoriertes Benzothiadiazol und Dithiophen beinhaltet, verwendet. Als Elektronenakzeptor finden ein planares 3,4:9,10-Perylentetracarbonsäurediimid-(PDI)-Derivat und verschiedene Fullerenderivate Anwendung. PDI-Derivate gelten als vielversprechende Alternativen zu Fullerenen aufgrund der durch chemische Synthese abstimmbaren strukturellen, optischen und elektronischen Eigenschaften. Das gewichtigste Argument für PDI-Derivate ist deren Absorption im sichtbaren Bereich des Sonnenspektrums was den Photostrom verbessern kann. Fulleren-basierte Mischungen übertreffen jedoch für gewöhnlich die Effizienz von Donor-PDI-Mischungen.rnUm den Nachteil der PDI-basierten Mischungen im Vergleich zu den entsprechenden Fulleren-basierten Mischungen zu identifizieren, werden die verschiedenen Donor-Akzeptor-Kombinationen auf ihre optischen, elektronischen und strukturellen Eigenschaften untersucht. Zeitaufgelöste Spektroskopie, vor allem transiente Absorptionsspektroskopie (TA), wird zur Analyse der Ladungsgeneration angewendet und der Vergleich der Donor-PDI Mischfilme mit den Donor-Fulleren Mischfilmen zeigt, dass die Bildung von Ladungstransferzuständen einen der Hauptverlustkanäle darstellt.rnWeiterhin werden Mischungen aus PBDTTT-C und [6,6]-Phenyl-C61-buttersäuremethylesther (PC61BM) mittels TA-Spektroskopie auf einer Zeitskala von ps bis µs untersucht und es kann gezeigt werden, dass der Triplettzustand des Polymers über die nicht-geminale Rekombination freier Ladungen auf einer sub-ns Zeitskala bevölkert wird. Hochentwickelte Methoden zur Datenanalyse, wie multivariate curve resolution (MCR), werden angewendet um überlagernde Datensignale zu trennen. Zusätzlich kann die Regeneration von Ladungsträgern durch Triplett-Triplett-Annihilation auf einer ns-µs Zeitskala gezeigt werden. Darüber hinaus wird der Einfluss des Lösungsmitteladditivs 1,8-Diiodooctan (DIO) auf die Leistungsfähigkeit von p-DTS(FBTTh2)2:PDI Solarzellen untersucht. Die Erkenntnisse von morphologischen und photophysikalischen Experimenten werden kombiniert, um die strukturellen Eigenschaften und die Photophysik mit den relevanten Kenngrößen des Bauteils in Verbindung zu setzen. Zeitaufgelöste Photolumineszenzmessungen (time-resolved photoluminescence, TRPL) zeigen, dass der Einsatz von DIO zu einer geringeren Reduzierung der Photolumineszenz führt, was auf eine größere Phasentrennung zurückgeführt werden kann. Außerdem kann mittels TA Spektroskopie gezeigt werden, dass die Verwendung von DIO zu einer verbesserten Kristallinität der aktiven Schicht führt und die Generation freier Ladungen fördert. Zur genauen Analyse des Signalzerfalls wird ein Modell angewendet, das den gleichzeitigen Zerfall gebundener CT-Zustände und freier Ladungen berücksichtigt und optimierte Donor-Akzeptor-Mischungen zeigen einen größeren Anteil an nicht-geminaler Rekombination freier Ladungsträger.rnIn einer weiteren Fallstudie wird der Einfluss des Fullerenderivats, namentlich IC60BA und PC71BM, auf die Leistungsfähigkeit und Photophysik der Solarzellen untersucht. Eine Kombination aus einer Untersuchung der Struktur des Dünnfilms sowie zeitaufgelöster Spektroskopie ergibt, dass Mischungen, die ICBA als Elektronenakzeptor verwenden, eine schlechtere Trennung von Ladungstransferzuständen zeigen und unter einer stärkeren geminalen Rekombination im Vergleich zu PCBM-basierten Mischungen leiden. Dies kann auf die kleinere Triebkraft zur Ladungstrennung sowie auf die höhere Unordnung der ICBA-basierten Mischungen, die die Ladungstrennung hemmen, zurückgeführt werden. Außerdem wird der Einfluss reiner Fullerendomänen auf die Funktionsfähigkeit organischer Solarzellen, die aus Mischungen des Thienothienophen-basierenden Polymers pBTTT-C14 und PC61BM bestehen, untersucht. Aus diesem Grund wird die Photophysik von Filmen mit einem Donor-Akzeptor-Mischungsverhältnis von 1:1 sowie 1:4 verglichen. Während 1:1-Mischungen lediglich eine co-kristalline Phase, in der Fullerene zwischen den Seitenketten von pBTTT interkalieren, zeigen, resultiert der Überschuss an Fulleren in den 1:4-Proben in der Ausbildung reiner Fullerendomänen zusätzlich zu der co kristallinen Phase. Transiente Absorptionsspektroskopie verdeutlicht, dass Ladungstransferzustände in 1:1-Mischungen hauptsächlich über geminale Rekombination zerfallen, während in 1:4 Mischungen ein beträchtlicher Anteil an Ladungen ihre wechselseitige Coulombanziehung überwinden und freie Ladungsträger bilden kann, die schließlich nicht-geminal rekombinieren.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resonante Laserionisations-Massenspektrometrie an Gadolinium zur Isotopenhäufigkeitsanalyse mit geringsten Mengen Die selektive Spuren- und Ultraspurenanalyse des Erdalkalielements Gadolinium eröffnet eine Vielzahl von Anwendungen in der Biomedizin und Kosmochemie. Zum Erreichen der hohen Anforderungen bezüglich Isotopen- und Isobarenselektivität von S>10^7 sowie Gesamteffizienz von e>10^-6 wurde der Einsatz der resonanten Laserionisations-Massenspektrometrie untersucht. Dazu erfolgte die Weiterentwicklung und Anpassung des existierenden Diodenlaser-Quadrupolmassenspektrometersystems. Durch Ionenflugbahn-Simulationsrechnungen wurde für das Quadrupol-Massenspektrometer die erreichbare Nachbarmassenunterdrückung und Transmission in Abhängigkeit von der Auflösung theoretisch vorhergesagt. Die Werte wurden experimentell bestätigt. Aus der beobachteten Peakstruktur erfolgte die Ableitung einer Methode zur Bestimmung der Energieunschärfe des eingesetzten Ionisationsprozesses. Zum Auffinden eines effizienten dreifach resonanten Anregungsschemas wurden die Isotopieverschiebungen und Hyperfeinstrukturen aller stabilen Gadoliniumisotope in zahlreichen Übergängen für die einfach, zweifach und dreifach resonante Ionisation präzise vermessen. Das aufgenommene Spektrum autoionisierender Resonanzen zeigte etwa 150 bislang unbekannter Zustände mit Resonanzüberhöhungen von bis zu fünf Größenordnungen im Ionisationswirkungsquerschnitt. Die entwickelte Methode der Hyperfeinzustandsselektion ermöglichte die Bestimmung der Drehimpulsquantenzahl J der autoionisierenden Resonanzen. Die analytische Charakterisierung der dreistufig resonanten Ionisation von Gadolinium ergab eine Isotopen- und Isobarenselektivität von S(Isotop)>10^12 und S(Isobar)>10^7. Die mit dem Diodenlasersystem erreichte Nachweiseffizienz von e=1-3x10^-6 mit einer untergrundlimitierten Nachweisgrenze von wenigen 10^9 Atomen Gd-158 erlaubte erste Demonstrationsmessungen an medizinischen Gewebeproben.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, pterosaur skull constructions were analysed using a combined approach of finite element analysis (FEA), static investigations as well as applying classical beam theory and lever mechanics. The study concentrates on the operating regime „bite“, where loads are distributed via the dentition or a keratinous rhamphotheca into the skull during jaw occlusion. As a first step, pterosaur tooth constructions were analysed. The different morphologies of the tooth construction determine specific operational ranges, in which the teeth perform best (= greatest resistance against failure). The incomplete enamel-covering of the pterosaur tooth constructions thereby leads to a reduction of strain and stress and to a greater lateral elasticity than for a complete enamel cover. This permits the development of high and lateral compressed tooth constructions. Further stress-absorption occurs in the periodontal membrane, although its mechanical properties can not be clarified unambiguously. A three-dimensionally preserved skull of Anhanguera was chosen as a case-study for the investigation of the skull constructions. CT-scans were made to get information about the internal architecture, supplemented by thin-sections of a rostrum of a second Anhanguera specimen. These showed that the rostrum can be approximated as a double-walled triangular tube with a large central vacuity and an average wall-thickness of the bony layers of about 1 mm. On base of the CT-scans, a stereolithography of the skull of Anhanguera was made on which the jaw adductor and abductor muscles were modelled, permitting to determine muscular forces. The values were used for the lever mechanics, cantilever and space frame analysis. These studies and the FEA show, that the jaw reaction forces are critical for the stability of the skull construction. The large jugal area ventral to the orbita and the inclined occipital region act as buttresses against these loads. In contrast to the orbitotemporal region which is subject to varying loading conditions, the pattern in the rostrum is less complex. Here, mainly bending in dorsal direction and torsion occur. The hollow rostrum leads to a reduction of weight of the skull and to a high bending and torsional resistance. Similar to the Anhanguera skull construction, the skulls of those pterosaur taxa were analysed, from which enough skull material is know to permit a reliable reconstruction. Furthermore, FEA were made from five selected taxa. The comparison of the biomechanical behaviour of the different skull constructions results in major transformational processes: elongation of rostra, inclination of the occipital region, variation of tooth morphology, reduction of the dentition and replacement of teeth by a keratinous hook or rhamphotheca, fusion of naris and antorbital fenestra, and the development of bony and soft-tissue crests. These processes are discussed for their biomechanical effects during bite. Certain optional operational ranges for feeding are assigned to the different skull constructions and previous hypotheses (e.g. skimming) are verified. Using the principle of economisation, these processes help to establish irreversible transformations and to define possible evolutionary pathways. The resulting constructional levels and the structural variations within these levels are interpreted in light of a greater feeding efficiency and reduction of bony mass combined with an increased stability against the various loads. The biomechanical conclusive pathways are used for comparison and verification of recent hypothesis of the phylogenetic systematics of pterosaurs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit werden zwei Arten von nicht-kovalent verknüpften Netzwerkstrukturen vorgestellt, die aus phosphonsäurehaltigen Molekülen aufgebaut sind. Einerseits sollen diese phosphonsäurehaltigen Moleküle als Protonenleiter in Brennstoffzellen eingesetzt werden. Dies ist durch die Möglichkeit des kooperativen Protonentransports in wasserstoffbrückenhaltigen Netzwerken begründet. Auf der anderen Seite sollen die phosphonsäurehaltigen Moleküle unter Einsatz von Metallkationen zur Darstellung ionischer Netzwerke verwendet werden. In diesem Fall fungieren die phosphonierten Moleküle als Linker in porösen organisch-anorganischen Hybridmaterialien, die sich beispielsweise zur Gasspeicherung eignen.rnEine Brennstoffzelle stellt Energie mit hoher Effizienz und geringer Umweltbelastung bereit. Das Herzstück der Brennstoffzelle ist die Elektrolytmembran, die auch als Separator oder Protonenaustauschmembran (PEM) bezeichnet wird. Es wird davon ausgegangen, daß der Schlüssel zur Weiterentwicklung der PEM-Brennstoffzellen in der Entwicklung von Elektrolyten liegt, die ausschließlich und effizient Protonen transportieren und darüber hinaus chemisch (oxidationsbeständig) und mechanisch stabil sind. Die mechanische Stabilität betrifft insbesondere den Betrieb der Brennstoffzelle bei hohen Temperaturen und niedriger relativer Feuchtigkeit. In dieser Arbeit wird ein neuartiger Ansatz zum Erreichen eines hohen Protonentransports im Festkörper vorgestellt, der auf dem Einsatz kleiner Moleküle beruht, die durch Selbstorganisation eine kontinuierliche protonenleitende Phase erzeugen. Bis jetzt stellt Hexakis(p-phosphonatophenyl)benzol das erste Beispiel eines kristallinen Protonenleiters dar, der im festen Zustand eine hohe und konstante Leistung zeigt. Die Modifizierung von Hexakis(p-phosphonatophenyl)benzol, entweder durch Änderung von para- zu meta-Substitution oder die Einführung von Alkylketten, führt zu Verbindungen geringerer Kristallinität und niedriger Protonenleitfähigkeit.rnIm zweiten Teil der Arbeit wurde 1,3,5-Tris(p-phosphonatophenyl)benzol als Linker in der Synthese von offenen Phosphonat-Netzwerken eingesetzt. Es bilden sich aufgrund der ionischen Wechselwirkung zwischen den positiv geladenen Metallkationen und den negativ geladenen Phosphonsäuregruppen hochstabile Feststoffe. Eines der wichtigsten Ergebnisse dieser Arbeit besteht darin, daß 1,3,5-Tris(p-phosphonatophenyl)benzol als Linker zum Aufbau poröser Hybridmaterialien eingesetzt werden kann. Zum ersten Mal wurde ein dreifach phosphoniertes organisches Molekül zum Aufbau mikroporöser offener Phosphonat-Netzwerke verwendet. Zudem konnte gezeigt werden, daß die Porosität mit dem Wachstumsmechanismus dieser Materialien zusammenhängt. Es ist nur dann möglich ein gleichfalls mikroporöses und kristallines ionisches Netzwerk auf der Grundlage phosphonierter Moleküle zu erhalten, wenn Linker und Konnektor die gleiche Geometrie und Funktionalität besitzen.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study the Aerodyne Aerosol Mass Spectrometer (AMS) was used during three laboratory measurement campaigns, FROST1, FROST2 and ACI-03. The FROST campaigns took place at the Leipzig Aerosol Cloud Interaction Simulator (LACIS) at the IfT in Leipzig and the ACI-03 campaign was conducted at the AIDA facility at the Karlsruhe Institute of Technology (KIT). In all three campaigns, the effect of coatings on mineral dust ice nuclei (IN) was investigated. During the FROST campaigns, Arizona Test Dust (ATD) particles of 200, 300 and 400 nm diameter were coated with thin coatings (< 7 nm) of sulphuric acid. At these very thin coatings, the AMS was operated close to its detection limits. Up to now it was not possible to accurately determine AMS detection limits during regular measurements. Therefore, the mathematical tools to analyse the detection limits of the AMS have been improved in this work. It is now possible to calculate detection limits of the AMS under operating conditions, without losing precious time by sampling through a particle filter. The instrument was characterised in more detail to enable correct quantification of the sulphate loadings on the ATD particle surfaces. Correction factors for the instrument inlet transmission, the collection efficiency, and the relative ionisation efficiency have been determined. With these corrections it was possible to quantify the sulphate mass per particle on the ATD after the condensation of sulphuric acid on its surface. The AMS results have been combined with the ice nucleus counter results. This revealed that the IN-efficiency of ATD is reduced when it is coated with sulphuric acid. The reason for this reduction is a chemical reaction of sulphuric acid with the particle's surface. These reactions are increasingly taking place when the aerosol is humidified or heated after the coating with sulphuric acid. A detailed analysis of the solubility and the evaporation temperature of the surface reaction products revealed that most likely aluminium sulphate is produced in these reactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Leishmaniose gehört zu den „vernachlässigten tropischen Erkrankungen“. Sie wird durch parasitäre Protozoen der Gattung Leishmania ausgelöst. Weltweit sind ca. 12 Mio. Menschen infiziert, ca. 70 Tausend erliegen ihr jährlich. Die aktuelle Therapie wird überschattet von Toxizitäts- und Teratogenitätsproblemen und von aufkommenden Resistenzen. Die von den Leishmanien exprimierten Cysteinproteasen spielen vielfältige Rollen bei Wachstum und Vermehrung der Erreger. Aufgrund der evolutionären Verwandtschaft der Enzyme sind die parasitären Cysteinproteasen strukturell den humanen sehr ähnlich. Die Herausforderung bei der Entwicklung antiparasitärer Wirkstoffe, basierend auf der Hemmung dieser Proteasen, besteht deshalb darin, sehr selektive Inhibitoren zu entwickeln, die die Wirtsproteasen nicht, oder nur in einem vertretbaren Rahmen, inhibieren. Das Ziel dieser Arbeit war die Weiterentwicklung der Aziridin-2,3-dicarbonsäure-basierten Cysteinproteaseinhibitoren RV122C bzw. CS09 hinsichtlich Selektivität und Aktivität gegenüber der parasitären Cathepsin-L-ähnlichen Cystein-Protease LmCPB2.8 durch Design, incl. Docking, Synthese und Testung. Neben der gezielten Variation nicht essenzieller Gruppen wurde molekulares Docking mittels AutoDock Vina an Cruzain als verwandtes Modellenzym durchgeführt, um durch Variationen K.O.-Kandidaten für die Differenzierung zwischen zwei postulierten Bindungsmodi zu finden. Die Ergebnisse der Enzymassays zeigen eine Verbesserung der Hemmeigenschaften bei gleichzeitig verbesserter Selektivität sowie erhöhter ligand efficiency und ligand lipophilic efficiency für Derivate mit sterisch anspruchsvolleren Ester-Resten und für Derivate mit einer freien Carbonsäurefunktion am Aziridin-Ring (Halbester).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Funktionsweise der Laserionenquellenfalle LIST, sowie deren Implementierung bei der Forschungseinrichtung ISOLDE am CERN als neue Standard-Ionenquelle und die ermittelten Spezifikationen Effizienz und Selektivität werden vorgestellt.rnrnDurch die Implementierung der LIST bei ISOLDE konnte on-line mit Hilfe von Radionukliden ein Minimalwert zur Unterdrückung von Kontaminationen durch die LIST bestimmt werden. Die erfolgreiche Unterdrückung von Francium-Kontamination ermöglichte es, neue Messdaten für den mittleren Ladungsradius und die Hyperfeinstruktur für Po-217 zu erzeugen.rnrnUm die Funktionalität der LIST bei ISOLDE hinsichtlich der Ionisationseffizienz gegenüber anderen Ionenquellen einzuordnen, wurden in Mainz am RISIKO-Massenseparator mit der bereits existierenden Standard-Ionenquelle RILIS und der LIST die Effizienzen bestimmt und miteinander verglichen. Es konnte gezeigt werden, dass die LIST im Modus hoher Ionisationseffizienz eine vergleichbare Effizienz aufweist wie die RILIS. Im Modus zur Produktion eines hochreinen Ionenstrahls ist die Ionisationseffizienz gegenüber der RILIS reduziert.rnrnDa die Bestimmung der Selektivität im On-line-Betrieb aufwendig und zeitintensiv ist, wurde die Reinheit des Ionenstrahls am RISIKO-Massenseparator mittels Laufzeitmessungen der Ionen off-line bestimmt und analysiert. Die Zeitstrukturen der RILIS ermöglichen einerseits Rückschlüsse auf die Reinheit des Ionenstrahls zu ziehen, andererseits konnte auch die Ionisation außerhalb des Atomisators, in dem überwiegend die resonante Ionisation stattfindet, nachgewiesen werden. Durch diesen Nachweis kann der Effizienzverlust während der Produktion eines hochreinen Ionenstrahls erklärt werden. Zudem bietet er einen Ansatz für weitere Entwicklungsarbeiten der LIST zur Steigerung der Effizienz.rnrnEine Übertragung der Messergebnisse zur Zeitstruktur der RILIS auf die LIST eröffnet neue Möglichkeiten zur Steigerung deren Selektivität im massenselektiven Mode. Dieser wurde anhand von Simulationen überprüft und mit Messungen an Kalium experimentell quantifiziert.