4 resultados para Fourier transform (FT)

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of this thesis was to further extend the applicability of the Fourier-transform (FT) rheology technique especially for non-linear mechanical characterisation of polymeric materials on the one hand and to investigated the influence of the degree of branching on the linear and non-linear relaxation behaviour of polymeric materials on the other hand. The latter was achieved by employing in particular FT-rheology and other rheological techniques to variously branched polymer melts and solutions. For these purposes, narrowly distributed linear and star-shaped polystyrene and polybutadiene homo-polymers with varying molecular weights were anionically synthesised using both high-vacuum and inert atmosphere techniques. Furthermore, differently entangled solutions of linear and star-shaped polystyrenes in di-sec-octyl phthalate (DOP) were prepared. The several linear polystyrene solutions were measured under large amplitude oscillatory shear (LAOS) conditions and the non-linear torque response was analysed in the Fourier space. Experimental results were compared with numerical predictions performed by Dr. B. Debbaut using a multi-mode differential viscoelastic fluid model obeying the Giesekus constitutive equation. Apart from the analysis of the relative intensities of the harmonics, a detailed examination of the phase information content was developed. Further on, FT-rheology allowed to distinguish polystyrene melts and solutions due to their different topologies where other rheological measurements failed. Significant differences occurred under LAOS conditions as particularly reflected in the phase difference of the third harmonic, Ħ3, which could be related to shear thinning and shear thickening behaviour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of shear fields on water-based systems was investigated within this thesis. The non-linear rheological behaviour of spherical and rod-like particles was examined with Fourier-Transform rheology under LAOS conditions. As a model system for spherical particles two different kinds of polystyrene dispersions, with a solid content higher than 0.3 each, were synthesised within this work. Due to the differences in polydispersity and Debye-length, differences were also found in the rheology. In the FT-rheology both kinds of dispersions showed a similar rise in the intensities of the magnitudes of the odd higher harmonics, which were predicted by a model. The in some cases additionally appearing second harmonics were not predicted. A novel method to analyse the time domain signal was developed, that splits the time domain signal up in four characteristic functions. Those characteristic functions correspond to rheological phenomena. In some cases the intensities of the Fourier components can interfere negatively. FD-virus particles were used as a rod-like model system, which already shows a highly non-linear behaviour at concentrations below 1. % wt. Predictions for the dependence of the higher harmonics from the strain amplitude described the non-linear behaviour well at large, but no so good at small strain amplitudes. Additionally the trends of the rheological behaviour could be described by a theory for rod-like particles. An existing rheo-optical set-up was enhanced by reducing the background birefringence by a factor of 20 and by increasing the time resolution by a factor of 24. Additionally a combination of FT-rheology and rheo-optics was achieved. The influence of a constant shear field on the crystallisation process of zinc oxide in the presence of a polymer was examined. The crystallites showed a reduction in length by a factor of 2. The directed addition of polymers in combination with a defined shear field can be an easy way for a defined change of the form of crystallites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of ß-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A = 90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-fligh ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ< 1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Untersuchungen zu ionenchemischen Reaktionen und Mobilitätsmessungen an schweren Elementen in einer Puffergaszelle Die vorgelegte Arbeit beschreibt vorbereitende Untersuchungen zu ionenchemischen Reaktionen und Mobilitätsmessungen schwerer Elemente (Z>100) in einer mit Argon gefüllten Puffergaszelle. Dazu wurden am Element Erbium (Z=68), dem chemischen Homolog von Fermium (Z=100), zunächst in einem Fourier-Transformations-Massenspektrometer (FT/MS) Reaktionen mit Sauerstoff (O2), Methan (CH4) und Butylen (C4H8) untersucht und deren Reaktionskonstanten zu k(Er+O2)=(3,6±0,3)•10-10cm3/s, k(Er+C4H8)=(1,3±0,1)•10-10cm3/s gemessen. Für die Reaktion Er++CH4 wurde eine Obergrenze der Reaktionskonstante von k(Er+CH4)?,3•10-15cm3/s bestimmt. Dieselben Reaktionen wurden anschließend in einer mit 60 mbar Argon gefüllten Puffergaszelle am Tandembeschleuniger des Max-Planck-Instituts für Kernphysik in Heidelberg studiert.Das in die Zelle eingeschossene Erbium wurde nach der Thermalisierung in einem zweistufigen Laserprozess resonant ionisiert. Diese Messungen führten zu gleichen Ergebnissen wie die FT/MS-Messungen (k(Er+O2)=3,3±0,4)•10-10cm3/s, k(Er+CH4)?2•10-17cm3/s). Die Reaktion von Erbium mit Butylen wurde ebenfalls beobachtet, eine Reaktionskonstante konnte jedoch nicht bestimmt werden. Die Reaktion von Erbium mit Sauerstoff wurde auch mit den direkt in die Puffergaszelle eingeschossenen Ionen ohne Laserionisation untersucht. Eine reproduzierbare Reaktionskonstante konnte nicht bestimmt werden, mögliche Ursachen werden diskutiert.Aus der Driftzeit der Ionen im Puffergas können Ionenmobilitäten bestimmt werden. Dies erlaubt Rückschlüsse auf die Ionenradien und damit auch auf Bindungslängen in Molekülen. Zwischen Plutonium und Americium wurde bei einer Driftzeit von (1,88±0,01) ms ein Driftzeitunterschied von (0,07±0,02) ms gemessen und daraus eine relative Verringerung des Ionenradius von Americium gegenüber dem von Plutonium um (3,1±1,3)% bestimmt. Relativistische Rechnungen sagen für den atomaren Radius von Americium gegenüber Plutonium eine Kontraktion in gleicher Größenordnung voraus; für Ionenradien existieren zur Zeit noch keine Rechnungen. Aus den gemessenen Driftzeiten des Plutoniums von (1,85±0,01) ms und Plutoniumoxids von (2,38±0,01) ms wurde eine Zunahme des Ionenradius des Plutoniumoxids gegenüber dem Plutonium um (28±2)% bestimmt.Außerdem wurden Reaktionen von Ruthenium (Z=44) und Osmium (Z=76), beides chemische Homologe von Hassium (Z=108), mit Sauerstoff in der FT/MS-Apparatur untersucht, mit dem Ziel widersprüchliche Messungen der Reaktionskonstanten aufzuklären.