11 resultados para ELASTIC SCATTERING

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The proton-nucleus elastic scattering at intermediate energies is a well-established method for the investigation of the nuclear matter distribution in stable nuclei and was recently applied also for the investigation of radioactive nuclei using the method of inverse kinematics. In the current experiment, the differential cross sections for proton elastic scattering on the isotopes $^{7,9,10,11,12,14}$Be and $^8$B were measured. The experiment was performed using the fragment separator at GSI, Darmstadt to produce the radioactive beams. The main part of the experimental setup was the time projection ionization chamber IKAR which was simultaneously used as hydrogen target and a detector for the recoil protons. Auxiliary detectors for projectile tracking and isotope identification were also installed. As results from the experiment, the absolute differential cross sections d$sigma$/d$t$ as a function of the four momentum transfer $t$ were obtained. In this work the differential cross sections for elastic p-$^{12}$Be, p-$^{14}$Be and p-$^{8}$B scattering at low $t$ ($t leq$~0.05~(GeV/c)$^2$) are presented. The measured cross sections were analyzed within the Glauber multiple-scattering theory using different density parameterizations, and the nuclear matter density distributions and radii of the investigated isotopes were determined. The analysis of the differential cross section for the isotope $^{14}$Be shows that a good description of the experimental data is obtained when density distributions consisting of separate core and halo components are used. The determined {it rms} matter radius is $3.11 pm 0.04 pm 0.13$~fm. In the case of the $^{12}$Be nucleus the results showed an extended matter distribution as well. For this nucleus a matter radius of $2.82 pm 0.03 pm 0.12$~fm was determined. An interesting result is that the free $^{12}$Be nucleus behaves differently from the core of $^{14}$Be and is much more extended than it. The data were also compared with theoretical densities calculated within the FMD and the few-body models. In the case of $^{14}$Be, the calculated cross sections describe the experimental data well while, in the case of $^{12}$Be there are discrepancies in the region of high momentum transfer. Preliminary experimental results for the isotope $^8$B are also presented. An extended matter distribution was obtained (though much more compact as compared to the neutron halos). A proton halo structure was observed for the first time with the proton elastic scattering method. The deduced matter radius is $2.60pm 0.02pm 0.26$~fm. The data were compared with microscopic calculations in the frame of the FMD model and reasonable agreement was observed. The results obtained in the present analysis are in most cases consistent with the previous experimental studies of the same isotopes with different experimental methods (total interaction and reaction cross section measurements, momentum distribution measurements). For future investigation of the structure of exotic nuclei a universal detector system EXL is being developed. It will be installed at the NESR at the future FAIR facility where higher intensity beams of radioactive ions are expected. The usage of storage ring techniques provides high luminosity and low background experimental conditions. Results from the feasibility studies of the EXL detector setup, performed at the present ESR storage ring, are presented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In dieser Arbeit wurde die paritätsverletzende Asymmetrie in derrnquasielastischen Elektron-Deuteron-Streuung bei Q^2=0.23 (GeV/c)^2 mitrneinem longitudinal polarisierten Elektronstrahl bei einer Energie von 315rnMeV bestimmt. Die Messung erfolgte unter Rückwärtswinkeln. Der Detektor überdeckte einen polaren Streuwinkelbereichrnzwischen 140 und 150 deg. Das Target bestand aus flüssigemrnDeuterium in einer Targetzelle mit einer Länge von 23.4 cm. Dierngemessene paritätsverletzende Asymmetrie beträgt A_{PV}^d = (-20.11 pm 0.87_{stat} pm 1.03_{syst}), wobei der erste Fehler den statistischenrnFehlereitrag und der zweite den systematischen Fehlerbeitrag beschreibt. Ausrnder Kombination dieser Messung mit Messungen der paritätsverletzendenrnAsymmetrie in der elastischen Elektron-Proton-Streuung bei gleichem Q^2rnsowohl bei Vorwärts- als auch bei Rückwärtsmessungen können diernVektor-Strange-Formfaktoren sowie der effektive isovektorielle und isoskalarernVektorstrom des Protons, der die elektroschwachen radiativen Anapolkorrekturenrnenthält, bestimmt werden. Diese Arbeit umfasst ausserdem die Bestimmungrnder Asymmetrien bei einem transversal polarisierten Elektronstrahl sowohl beirneinem Proton- als auch einem Deuterontarget unter Rückwärtswinkeln beirnImpulsüberträgen von Q^2=0.10 (GeV/c)^2, Q^2=0.23 (GeV/c)^2rnund Q^2=0.35 (GeV/c)^2. Die im Experiment beobachteten Asymmetrien werdenrnmit theoretischen Berechnungen verglichen, welche den Imaginärteil der Zweiphoton-Austauschamplitude beinhalten.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Drei-Spektrometer-Anlage am Mainzer Institut für Kernphysik wurde um ein zusätzliches Spektrometer ergänzt, welches sich durch seine kurze Baulänge auszeichnet und deshalb Short-Orbit-Spektrometer (SOS) genannt wird. Beim nominellen Abstand des SOS vom Target (66 cm) legen die nachzuweisenden Teilchen zwischen Reaktionsort und Detektor eine mittlere Bahnlänge von 165 cm zurück. Für die schwellennahe Pionproduktion erhöht sich dadurch im Vergleich zu den großen Spektrometern die Überlebenswahrscheinlichkeit geladener Pionen mit Impuls 100 MeV/c von 15% auf 73%. Demzufolge verringert sich der systematische Fehler ("Myon-Kontamination"), etwa bei der geplanten Messung der schwachen Formfaktoren G_A(Q²) und G_P(Q²), signifikant. Den Schwerpunkt der vorliegenden Arbeit bildet die Driftkammer des SOS. Ihre niedrige Massenbelegung (0,03% X_0) zur Reduzierung der Kleinwinkelstreuung ist auf den Nachweis niederenergetischer Pionen hin optimiert. Aufgrund der neuartigen Geometrie des Detektors musste eine eigene Software zur Spurrekonstruktion, Effizienzbestimmung etc. entwickelt werden. Eine komfortable Möglichkeit zur Eichung der Driftweg-Driftzeit-Relation, die durch kubische Splines dargestellt wird, wurde implementiert. Das Auflösungsvermögen des Spurdetektors liegt in der dispersiven Ebene bei 76 µm für die Orts- und 0,23° für die Winkelkoordinate (wahrscheinlichster Fehler) sowie entsprechend in der nicht-dispersiven Ebene bei 110 µm bzw. 0,29°. Zur Rückrechnung der Detektorkoordinaten auf den Reaktionsort wurde die inverse Transfermatrix des Spektrometers bestimmt. Hierzu wurden an Protonen im ¹²C-Kern quasielastisch gestreute Elektronen verwendet, deren Startwinkel durch einen Lochkollimator definiert wurden. Daraus ergeben sich experimentelle Werte für die mittlere Winkelauflösung am Target von sigma_phi = 1,3 mrad bzw. sigma_theta = 10,6 mrad. Da die Impulseichung des SOS nur mittels quasielastischer Streuung (Zweiarmexperiment) durchgeführt werden kann, muss man den Beitrag des Protonarms zur Breite des Piks der fehlenden Masse in einer Monte-Carlo-Simulation abschätzen und herausfalten. Zunächst lässt sich nur abschätzen, dass die Impulsauflösung sicher besser als 1% ist.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die A4-Kollaboration am Mainzer Mikrotron MAMI erforscht die Struktur des Protons mit Hilfe der elastischen Streuung polarisierter Elektronen an unpolarisiertem Wasserstoff. Bei longitudinaler Polarisation wird eine paritätsverletzende Asymmetrie im Wirkungsquerschnitt gemessen, die Aufschluß über den Beitrag der Strangeness zu den Vektor-Formfaktoren des Protons gibt. Bei transversaler Polarisation treten azimutale Asymmetrien auf, die auf Beiträge des Zwei-Photon-Austauschs zum Wirkungsquerschnitt zurückzuführen sind und den Zugriff auf den Imaginärteil der Zwei-Photon-Amplitude ermöglichen. Im Rahmen der vorliegenden Arbeit wurden Messungen bei zwei Impulsüberträgen und jeweils Longitudinal- und Transversalpolarisation durchgeführt und analysiert. Im Vordergrund standen die Extraktion der Rohasymmetrien aus den Daten, die Korrekturen der Rohasymmetrien auf apparative Asymmetrien, die Abschätzung des systematischen Fehlers und die Bestimmung der Strange-Formfaktoren aus den paritätsverletzenden Asymmetrien. Bei den Messungen mit Longitudinalpolarisation wurden die Asymmetrien zu A=(-5.59 +- 0.57stat +- 0.29syst)ppm bei Q^2=0.23 (GeV/c)^2 und A=(-1.39 +- 0.29stat +- 0.12syst)ppm bei Q^2=0.11(GeV/c)^2 bestimmt. Daraus lassen sich die Linearkombinationen der Strange-Formfaktoren zu GEs+0.225GMs= 0.029 +- 0.034 bzw. GEs+0.106GMs=0.070+-0.035 ermitteln. Die beiden Resultate stehen in Übereinstimmung mit anderen Experimenten und deuten darauf hin, daß es einen nichtverschwindenden Strangeness-Beitrag zu den Formfaktoren gibt. Bei den Messungen mit Transversalpolarisation wurden die azimutalen Asymmetrien zu A=(-8.51 +- 2.31stat +-0.89syst)ppm bei E=855 MeV und Q^2=0.23(GeV/c)^2 und zu A=(-8.59 +- 0.89stat +- 0.83syst)ppm bei E=569 MeV und Q^2=0.11(GeV/c)^2 bestimmt. Die Größe der gemessenen Asymmetrien belegt, daß beim Zwei-Photon-Austausch neben dem Grundzustand des Protons vor allem auch angeregte Zwischenzustände einen wesentlichen Beitrag liefern.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die A4-Kollaboration am Mainzer Mikrotron MAMI erforscht die Struktur des Protons mit Hilfe der elastischen Streuung polarisierter Elektronen an unpolarisiertem Wasserstoff. Bei longitudinaler Polarisation wird die paritätsverletzende Asymmetrie im Wirkungsquerschnitt gemessen, die Aufschluss über den Strangeness-Beitrag zu den Vektor-Formfaktoren des Protons gibt. Insbesondere wurde eine Messung für Rückwärtsstreuwinkel bei einer Elektronenstrahlenergie von 319 MeV durchgeführt, die zusammen mit einem unter Vorwärtsstreuung bei gleichem Impulsübertrag bestimmten Wert die Separation der magnetischen und elektrischen Strangeness-Formfaktoren erlaubt. Im Rahmen der vorliegenden Arbeit wurde ein Elektroniksystem zur Energiemessung und Histogrammierung der auftretenden Einzelereignisse aufgebaut, das eine vernetzte Struktur aus 1022 Einzelkanälen besitzt und zur Verarbeitung einer Gesamtereignisrate von 100 MHz ausgelegt wurde. Für den experimentellen Betrieb wurden für alle Kanäle erforderliche Qualitäts-prüfungen und Eichmessungen vorgenommen. Die volle Funktionsfähigkeit des Systems zur Durchführung eines Zählratenexperiments für die paritätsverletzende Asymmetrie im Bereich von 10^{-6} wurde demonstriert. Um den bei rückwärtigen Streuwinkeln dominierenden inelastischen Untergrund an Photonen in den Spektren zu reduzieren, wurde das System außerdem um ein Taggersystem für Elektronen erweitert. Das Ergebnis einer vorläufigen Analyse für die paritätsverletzende Asymmetrie im Streuquerschnitt von longitudinal polarisierten Elektronen an unpolarisierten Protonen unter Rückwärtsstreuung bei einem Viererimpulsübertrag Q^2 = 0.23 GeV^2/c^2 beträgt A{PV}=(-16.37 +- 0.93 {stat} +- 0.69 {syst}) ppm. Für die Differenz der gemessenen Asymmetrie A{PV} und der theoretischen Vorhersage ohne Strangeness A{0}=(-16.27 +- 1.22) ppm ergibt sich A{S}= A{PV} - A{0} = (-0.10+-1.68) ppm. Mit dem bereits vorliegenden Wert der Vorwärtsstreuung von A{PV} = (-5.59+- 0.57 {stat} +- 0.29 {syst}) ppm kann ein Wert für den magnetischen bzw. elektrischen Formfaktor von G{M}^s = -0.01+- 0.15 bzw. G{E}^s = 0.034 +- 0.050 ermittelt werden.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main concern of the A4 parity violation experiment at the Mainzer Microtron accelerator facility is to study the electric and magnetic contributions of strange quarks to the charge and magnetism of the nucleons at the low momentum transfer region. More precisely, the A4 collaboration investigates the strange quarks' contribution to the electric and magnetic vector form factors of the nucleons. Thus, it is important that the A4 experiment uses an adequate and precise non-destructive online monitoring tool for the electron beam polarization when measuring single spin asymmetries in elastic scattering of polarized electrons from unpolarized nucleons. As a consequence, the A4 Compton backscattering polarimeter was designed and installed such that we can take the absolute measurement of the electron beam polarization without interruption to the parity violation experiment. The present study shows the development of an electron beam line that is called the chicane for the A4 Compton backscattering polarimeter. The chicane is an electron beam transport line and provides an interaction region where the electron beam and the laser beam overlap. After studying the properties of beam line components carefully, we developed an electron beam control system that makes a beam overlap between the electron beam and the laser beam. Using the system, we can easily achieve the beam overlap in a short time. The electron control system, of which the performance is outstanding, is being used in production beam times. And the study presents the development of a scintillating fiber electron detector that reduces the statistical error in the electron polarization measurement. We totally redesigned the scintillating fiber detector. The data that were taken during a 2008 beam time shows a huge background suppression, approximately 80 percent, while leaving the Compton spectra almost unchanged when a coincidence between the fiber detector and the photon detector is used. Thus, the statistical error of the polarization measurement is reduced by about 40 percent in the preliminary result. They are the significant progress in measuring a degree of polarization of the electron beam.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Im Rahmen des A4-Experiments werden die Beiträge des Strange-Quarks zu den elektromagnetischen Formfaktoren des Protons gemessen. Solche Seequarkeffekte bei Niederenergieobservablen sind für das Verständnis der Hadronenstruktur wichtig, denn sie stellen eine direkte Manifestation der QCD-Freiheitsgrade im nichtperturbativen Bereich dar.rnrnLinearkombinationen der Strangeness-Vektorformfaktoren des Protons $G_E^s$ und $G_M^s$ sind experimentell über die Messung der paritätsverletzenden Asymmetrie im Wirkungsquerschnitt der elastischen Streuung longitudinal polarisierter Elektronen an unpolarisierten Nukleonen zugänglich. Vor dieser Arbeit hatte die A4-Kollaboration zwei solche Messungen unter Vorwärtsstreuwinkeln bei den Viererimpulsübertägen $Q^2$ von jeweils 0.23 und 0.10 (GeV/c)$^2$ veröffentlicht. Um die Separation von $G_E^s$ und $G_M^s$ beim höheren $Q^2$-Wert zu erhalten, wurde eine Messung unter Rückwärtswinkeln mit der Strahlenergie von 315 MeV durchgeführt.rnrnIm A4-Experiment werden die an einem Flüssigwasserstoff-Target gestreuten Elektronen eines longitudinal polarisierten Strahls mit einem Cherenkov-Kalorimeter einzeln gezählt. Durch die kalorimetrische Energiemessung erfolgt die Trennung der elastischen von den inelastischen Ereignissen. Bei Rückwärtswinkeln wurde dieses Apparat mit einem Szintillator als Elektronentagger erweitert, um den $\gamma$-Untergrund aus dem $\pi^0$-Zerfall zu unterdrücken.rnrnUm die Auswertung dieser Messung zu ermöglichen, wurden im Rahmen dieser Arbeit die gemessenen Energiespektren anhand von ausführlichen Simulationen der Streuprozesse und des Antwortverhaltens der Detektoren untersucht, und eine Methode zur Behandlung des restlichen Untergrunds aus der $\gamma$-Konversionrnvor dem Szintillator entwickelt. Die Simulationergebnisse sind auf dem 5%-Niveau mit den Messungen verträglich, und es wurde bewiesen, dass die Methode der Untergrundbehandlung anwendbar ist.rnrnDie Asymmetriemessung bei Rückwärtswinkeln, die man nach Anwendung der hier erarbeiteten Untergrundbehandlung erhält, wurde für die Separation von $G_E^s$ und $G_M^s$ bei $Q^2$=0.22 (GeV/c)^2 mit der Vorwärtswinkelmessung beim selbenrn$Q^2$ kombiniert. Es ergeben sich die Werte:rnrn$G_M^s$= -0.14 ± 0.11_{exp} ± 0.11_{theo} undrn$G_E^s$= 0.050 ± 0.038_{exp} ± 0.019_{theo}, rnrnwobei die systematische Unsicherheit wegen der Untergrundbehandlung im experimentellen Fehler enthalten ist. Am Ende der Arbeit werden die aus diesen Resultaten folgenden Rückschlüsse auf den Einfluss der Strangeness auf die statischen elektromagnetischen Eigenschaften des Protons diskutiert.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Spinpolarisationsmessungen an freien Elektronen sind seit ihrer ersten Verwirklichung durch Mott anspruchsvoll geblieben. Die relevante Größe eines Spinpolarimeters ist seine Gütefunktion, FoM = S^2*I/I_0, mit der Asymmetriefunktion S und dem Verhältnis aus Streu- und Primärintensität I/I_0. Alle bisherigen Geräte basieren auf einer einkanaligen Streuung (Spin-Bahn- oder Austauschwechselwirkung), die durch FoM = 10^(-4) charakterisiert ist. Moderne Halbkugelanalysatoren ermöglichen hingegen eine effiziente Vielkanaldetektion der spinintegralen Intensität mit mehr als 10^4 simultan erfassten Datenpunkten. Im Vergleich zwischen spinaufgelöster und spinintegraler Elektronenspektroskopie findet man somit einen Effizienzunterschied von 8 Größenordnungen.rnDie vorliegende Arbeit beschäftigt sich mit der Entwicklung und Untersuchung eines neuartigen Verfahrens zur Effizienzsteigerung in der spinaufgelösten Elektronenspektroskopie unter Ausnutzung von Vielkanaldetektion. Der Spindetektor wurde in eine µ-metallgeschirmte UHV-Kammer integriert und hinter einem konventionellen Halbkugelanalysator angebracht. Durch elektronenoptische Simulationen wurde die Geometrie des elektrostatischen Linsensystems festgelegt. Das Grundkonzept basiert auf der k(senkrecht)-erhaltenden elastischen Streuung des (0,0)-Spekularstrahls an einem W(100)- Streukristall unter einem Einfallswinkel von 45°. Es konnte gezeigt werden, dass etwarn960 Datenpunkte (15 Energie- und 64 Winkelpunkte) in einem Energiebereich vonrnetwa 3 eV simultan auf einen Delayline-Detektor abgebildet werden können. Dies führt zu einer zweidimensionalen Gütefunktion von FoM_2D = 1,7. Verglichen mit konventionellen Spindetektoren ist der neuartige Ansatz somit durch einen Effizienzgewinn von 4 Größenordnungen gekennzeichnet.rnDurch Messungen einer Fe/MgO(100) und O p(1x1)/Fe(100)-Probe konnte die Funktionstüchtigkeit des neuen Spinpolarimeters nachgewiesen werden, indem die aus der Literatur bekannten typischen UPS-Ergebnisse mit stark verkürzter Messzeit reproduziert wurden. Durch die hohe Effizienz ist es möglich, besonders reaktive Oberflächen in kurzer Zeit zu vermessen. Dieser Vorteil wurde bereits für eine erste grundlagenorientierte Anwendung genutzt: Als Test für die Gültigkeit von Bandstrukturrechnungen für die Heusler-Verbindung Co_2MnGa, wobei eine gute Übereinstimmung zwischen Theorie und Experiment gefunden wurde.rnMit dem Vielkanal-Spinfilter wurde die Grundlage zu einem um Größenordnungen verbesserten Messverfahren der Elektronenspin-Polarisation geschaffen und damit der Zugang zu Experimenten eröffnet, die mit den bisherigen einkanaligen Detektoren nicht möglich sind.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among all possible realizations of quark and antiquark assembly, the nucleon (the proton and the neutron) is the most stable of all hadrons and consequently has been the subject of intensive studies. Mass, shape, radius and more complex representations of its internal structure are measured since several decades using different probes. The proton (spin 1/2) is described by the electric GE and magnetic GM form factors which characterise its internal structure. The simplest way to measure the proton form factors consists in measuring the angular distribution of the electron-proton elastic scattering accessing the so-called Space-Like region where q2 < 0. Using the crossed channel antiproton proton <--> e+e-, one accesses another kinematical region, the so-called Time-Like region where q2 > 0. However, due to the antiproton proton <--> e+e- threshold q2th, only the kinematical domain q2 > q2th > 0 is available. To access the unphysical region, one may use the antiproton proton --> pi0 e+ e- reaction where the pi0 takes away a part of the system energy allowing q2 to be varied between q2th and almost 0. This thesis aims to show the feasibility of such measurements with the PANDA detector which will be installed on the new high intensity antiproton ring at the FAIR facility at Darmstadt. To describe the antiproton proton --> pi0 e+ e- reaction, a Lagrangian based approach is developed. The 5-fold differential cross section is determined and related to linear combinations of hadronic tensors. Under the assumption of one nucleon exchange, the hadronic tensors are expressed in terms of the 2 complex proton electromagnetic form factors. An extraction method which provides an access to the proton electromagnetic form factor ratio R = |GE|/|GM| and for the first time in an unpolarized experiment to the cosine of the phase difference is developed. Such measurements have never been performed in the unphysical region up to now. Extended simulations were performed to show how the ratio R and the cosine can be extracted from the positron angular distribution. Furthermore, a model is developed for the antiproton proton --> pi0 pi+ pi- background reaction considered as the most dangerous one. The background to signal cross section ratio was estimated under different cut combinations of the particle identification information from the different detectors and of the kinematic fits. The background contribution can be reduced to the percent level or even less. The corresponding signal efficiency ranges from a few % to 30%. The precision on the determination of the ratio R and of the cosine is determined using the expected counting rates via Monte Carlo method. A part of this thesis is also dedicated to more technical work with the study of the prototype of the electromagnetic calorimeter and the determination of its resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation is devoted to the experimental exploration of the propagation of elastic waves in soft mesoscopic structures with submicrometer dimensions. A strong motivation of this work is the large technological relevance and the fundamental importance of the subject. Elastic waves are accompanied by time-dependent fluctuations of local stress and strain fields in the medium. As such, the propagation phase velocities are intimately related to the elastic moduli. Knowledge of the elastic wave propagation directly provides information about the mechanical properties of the probed mesoscopic structures, which are not readily accessible experimentally. On the other hand, elastic waves, when propagating in an inhomogeneous medium with spatial inhomogeneities comparable to their wavelength, exhibit rather rich behavior, including the appearance of novel physical phenomena, such as phononic bandgap formation. So far, the experimental work has been restricted to macroscopic structures, which limit wave propagation below the KHz range. It was anticipated that an experimental approach capable of probing the interplay of the wave propagation with the controlled mesoscopic structures would contribute to deeper insights into the fundamental problem of elastic wave propagation in inhomogeneous systems. The mesoscopic nature of the structures to be studied precludes the use of traditional methods, such as sound transmission, for the study of elastic wave propagation. In this work, an optical method utilizing the inelastic scattering of photons by GHz frequency thermally excited elastic waves, known as Brillouin light scattering spectroscopy (BLS), was employed. Two important classes of soft structures were investigated: thin films and colloidal crystals. For the former, the main interest was the effect of the one-dimensional (1D) confinement on the wave propagation due to the presence of the free-surface or interface of the layer and the utilization of these waves to extract relevant material parameters. For the second system, the primary interest was the interaction of the elastic wave and the strong scattering medium with local resonance units in a three-dimensional (3D) periodic arrangement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Materials that can mold the flow of elastic waves of certain energy in certain directions are called phononic materials. The present thesis deals essentially with such phononic systems, which are structured in the mesoscale (<1 µm), and with their individual components. Such systems show interesting phononic properties in the hypersonic region, i.e., at frequencies in the GHz range. It is shown that colloidal systems are excellent model systems for the realization of such phononic materials. Therefore, different structures and particle architectures are investigated by Brillouin light scattering, the inelastic scattering of light by phonons.rnThe experimental part of this work is divided into three chapters: Chapter 4 is concerned with the localized mechanical waves in the individual spherical colloidal particles, i.e., with their resonance- or eigenvibrations. The investigation of these vibrations with regard to the environment of the particles, their chemical composition, and the influence of temperature on nanoscopically structured colloids allows novel insights into the physical properties of colloids at small length scales. Furthermore, some general questions concerning light scattering on such systems, in dispute so far, are convincingly addressed.rnChapter 5 is a study of the traveling of mechanical waves in colloidal systems, consisting of ordered and disordered colloids in liquid or elastic matrix. Such systems show acoustic band gaps, which can be explained geometrically (Bragg gap) or by the interaction of the acoustic band with the eigenvibrations of the individual spheres (hybridization gap).rnWhile the latter has no analogue in photonics, the presence of strong phonon scatterers, when a large elastic mismatch between the composite components exists, can largely impact phonon propagation in analogy to strong multiple light scattering systems. The former is exemplified in silica based phononic structures that opens the door to new ways of sound propagation manipulation.rnChapter 6 describes the first measurement of the elastic moduli in newly fabricated by physical vapor deposition so-called ‘stable organic glasses’. rnIn brief, this thesis explores novel phenomena in colloid-based hypersonic phononic structures, utilizing a versatile microfabrication technique along with different colloid architectures provided by material science, and applying a non-destructive optical experimental tool to record dispersion diagrams.rn