2 resultados para Bridgton and Saco River Railroad Company.

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous and found in the atmosphere, aquatic environment, sediments and soils. For environmental risk assessments and the allocation of the polluter it is important to know the PAH sources. PAH contamination sites are usually the result of anthropogenic processes. Three major sources are known: i) petroleum, including crude oil and its refined products and coals (petrogenic PAHs), ii) burning of organic matter (pyrogenic PAHs) and iii) transformation products of natural organic precursors present in the environment (diagenetic processes). In one case elevated PAH concentrations were found in river bank soils when building a retention area along the Mosel River. The source of the PAHs in this area was unclear and required the investigation of possible sources. To evaluate the PAH distribution along the Mosel River, a section of ~ 160 km along the river and a short section along the Saar River were investigated within this study. Concentrations of the Σ16 EPA PAHs were as high as 81 mg kg-1 dry weight (dw). Additionally, coal particles were identified in some soils, which originated from mining activities in the Saarland region. PAH distribution patterns of the 16 EPA PAHs suggest a mainly pyrogenic origin and in some cases a mixture of pyrogenic and petrogenic origin. For a comprehensive investigation five sampling sites were selected. Two sites were located before the confluence of the Mosel and Saar River, one site at the confluence and two sites after the confluence. The examination included typical forensic methods such as PAH distribution patterns of 45 PAHs (including alkylated PAHs), calculation of PAH ratios, determination of PAH alkyl homologues, n-alkanes, principal component analysis (PCA) and coal petrography. The results revealed a mainly pyrogenic source at sampling sites before the confluence of the two rivers. At and after the confluence, a mixture of pyrogenic and petrogenic inputs were present. With the help of coal petrography, coal derived particles could be identified in these soils. Therefore, coal was suggested to be the petrogenic source. It could be shown that sites with diffuse sources of contaminants, like the bank soils of the Mosel River, are difficult to characterize. As previously mentioned for detailed source identifications, the use of various forensic methods is essential. Determination of PAH alkyl homologue series, biomarkers and isotopes are often recommended. Source identification was evaluated using three different methods (i.e. PAH distribution patterns of an extended PAH spectrum, PAH ratios and analyses of n-alkanes). It was assessed if these methods were sufficient for the initial steps in identifying sources of PAHs in selected samples, and if they could be used for decision-making purposes. Point- and non-point sources were identified by applying the three methods and it could be shown that these relatively simple methods are sufficient in determining the primary source. In a last step of this study two soils (one before the confluence of the Mosel and Saar rivers and one after the confluence), and one sediment of the Mosel River were evaluated by investigating the mutagenic potential of the soils and the sediment with a fluctuation version of the Ames-test. The study showed that coal bearing soils at the Mosel River do not exhibit a greater mutagenic potential than other soils or sediments without coal particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atmospheric aerosol particles serving as cloud condensation nuclei (CCN) are key elements of the hydrological cycle and climate. Knowledge of the spatial and temporal distribution of CCN in the atmosphere is essential to understand and describe the effects of aerosols in meteorological models. In this study, CCN properties were measured in polluted and pristine air of different continental regions, and the results were parameterized for efficient prediction of CCN concentrations.The continuous-flow CCN counter used for size-resolved measurements of CCN efficiency spectra (activation curves) was calibrated with ammonium sulfate and sodium chloride aerosols for a wide range of water vapor supersaturations (S=0.068% to 1.27%). A comprehensive uncertainty analysis showed that the instrument calibration depends strongly on the applied particle generation techniques, Köhler model calculations, and water activity parameterizations (relative deviations in S up to 25%). Laboratory experiments and a comparison with other CCN instruments confirmed the high accuracy and precision of the calibration and measurement procedures developed and applied in this study.The mean CCN number concentrations (NCCN,S) observed in polluted mega-city air and biomass burning smoke (Beijing and Pearl River Delta, China) ranged from 1000 cm−3 at S=0.068% to 16 000 cm−3 at S=1.27%, which is about two orders of magnitude higher than in pristine air at remote continental sites (Swiss Alps, Amazonian rainforest). Effective average hygroscopicity parameters, κ, describing the influence of chemical composition on the CCN activity of aerosol particles were derived from the measurement data. They varied in the range of 0.3±0.2, were size-dependent, and could be parameterized as a function of organic and inorganic aerosol mass fraction. At low S (≤0.27%), substantial portions of externally mixed CCN-inactive particles with much lower hygroscopicity were observed in polluted air (fresh soot particles with κ≈0.01). Thus, the aerosol particle mixing state needs to be known for highly accurate predictions of NCCN,S. Nevertheless, the observed CCN number concentrations could be efficiently approximated using measured aerosol particle number size distributions and a simple κ-Köhler model with a single proxy for the effective average particle hygroscopicity. The relative deviations between observations and model predictions were on average less than 20% when a constant average value of κ=0.3 was used in conjunction with variable size distribution data. With a constant average size distribution, however, the deviations increased up to 100% and more. The measurement and model results demonstrate that the aerosol particle number and size are the major predictors for the variability of the CCN concentration in continental boundary layer air, followed by particle composition and hygroscopicity as relatively minor modulators. Depending on the required and applicable level of detail, the measurement results and parameterizations presented in this study can be directly implemented in detailed process models as well as in large-scale atmospheric and climate models for efficient description of the CCN activity of atmospheric aerosols.