3 resultados para Bottle Labeling

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of organic fluorescent dyes are experiencing a renaissance related to the increasing demands posed by new microscopy techniques for high resolution and high sensitivity. While in the last decade single molecule equipment and methodology has significantly advanced and in some cases reached theoretical limits (e.g. detectors approaching unity quantum yields) unstable emission from chromophores and photobleaching become more and more the bottleneck of the advancement and spreading of single-molecule fluorescence studies. The main goal of this work was the synthesis of fluorophores that are water-soluble, highly fluorescent in an aqueous environment, have a reactive group for attachment to a biomolecule and posses exceptional photostability. An approach towards highly fluorescent, water-soluble and monofunctional perylene-3,4,9,10-tetracarboxdiimide and terrylene-3,4:11,12-tetra carboxidiimide chromophores was presented. A new synthetic strategy for the desymmetrization of perylenetetracarboximides was elaborated; water-solubility was accomplished by introducing sulfonyl substituents in the phenoxy ring. Two strategies have been followed relying on either non-specific or site specific labeling. For this purpose a series of new water-soluble monofunctional perylene and terrylene dyes, bearing amine or carboxy group were prepared. The reactivity and photophysical properties of these new chromophores were studied in aqueous medium. The most suitable chromophores were further derivatized with amine or thiol reactive groups, suitable for chemical modification of proteins. The performance of the new fluorescent probes was assessed by single molecule enzyme tracking, in this case phospholipase acting on phospholipid supported layers. Phospholipase-1 (PLA-1) was labeled with N-hydroxysuccinimide ester functionalized perylene and terrylene derivatives. The purification of the conjugates was accomplished by novel convenient procedure for the removal of unreacted dye from labeled enzymes, which involves capturing excess dye with a solid support. This novel strategy for purification of bioconjugates allows convenient and fast separation of labeled proteins without the need for performing time consuming chromatographic or electrophoretic purification steps. The outstanding photostability of the dyes and, associated therewith, the extended survival times under strong illumination conditions allow a complete characterization of enzyme action on its natural substrates and even connecting enzyme mobility to catalytic activity. For site-specific attachment of the rylene dyes to proteins the chromophores were functionalized with thioesters or nitrilotriacetic acid groups. This allowed attachment of the emitters to the N-terminus of proteins by native chemical ligation or complexation with His-tagged polypeptides at the N- or C-termini, respectively. The synthesis of a water-soluble perylenebis (dicarboximide) functionalized with a thioester group was presented. This chromophore exhibits an exceptional photostability and a functional unit for site-specific labeling of proteins. The suitability of the fluorophore as a covalent label was demonstrated via native chemical ligation with protein containing N-terminal cystein residue. We exploited also oligohisitidine sequences as recognition elements for site-selective labeling. The synthesis of a new water-soluble perylene chromophore, containing a nitrilotriacetic acid functional group was demonstrated, using solution-phase and solid-phase approaches. This chromophore combines the exceptional photophysical properties of the rylene dyes and a recognition unit for site-specific labeling of proteins. An important feature of the label is the unchanged emission of the dye upon complexation with nickel ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on the experimental realization, characterization and application of a novel microresonator design. The so-called “bottle microresonator” sustains whispering-gallery modes in which light fields are confined near the surface of the micron-sized silica structure by continuous total internal reflection. While whispering-gallery mode resonators in general exhibit outstanding properties in terms of both temporal and spatial confinement of light fields, their monolithic design makes tuning of their resonance frequency difficult. This impedes their use, e.g., in cavity quantum electrodynamics (CQED) experiments, which investigate the interaction of single quantum mechanical emitters of predetermined resonance frequency with a cavity mode. In contrast, the highly prolate shape of the bottle microresonators gives rise to a customizable mode structure, enabling full tunability. The thesis is organized as follows: In chapter I, I give a brief overview of different types of optical microresonators. Important quantities, such as the quality factor Q and the mode volume V, which characterize the temporal and spatial confinement of the light field are introduced. In chapter II, a wave equation calculation of the modes of a bottle microresonator is presented. The intensity distribution of different bottle modes is derived and their mode volume is calculated. A brief description of light propagation in ultra-thin optical fibers, which are used to couple light into and out of bottle modes, is given as well. The chapter concludes with a presentation of the fabrication techniques of both structures. Chapter III presents experimental results on highly efficient, nearly lossless coupling of light into bottle modes as well as their spatial and spectral characterization. Ultra-high intrinsic quality factors exceeding 360 million as well as full tunability are demonstrated. In chapter IV, the bottle microresonator in add-drop configuration, i.e., with two ultra-thin fibers coupled to one bottle mode, is discussed. The highly efficient, nearly lossless coupling characteristics of each fiber combined with the resonator's high intrinsic quality factor, enable resonant power transfers between both fibers with efficiencies exceeding 90%. Moreover, the favorable ratio of absorption and the nonlinear refractive index of silica yields optical Kerr bistability at record low powers on the order of 50 µW. Combined with the add-drop configuration, this allows one to route optical signals between the outputs of both ultra-thin fibers, simply by varying the input power, thereby enabling applications in all-optical signal processing. Finally, in chapter V, I discuss the potential of the bottle microresonator for CQED experiments with single atoms. Its Q/V-ratio, which determines the ratio of the atom-cavity coupling rate to the dissipative rates of the subsystems, aligns with the values obtained for state-of-the-art CQED microresonators. In combination with its full tunability and the possibility of highly efficient light transfer to and from the bottle mode, this makes the bottle microresonator a unique tool for quantum optics applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive molecular-imaging technologies are playing a key role in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various deceases in vivo. However, it is limited by the availability of vectors with high selectivity to the target and radionuclides with a physical half-life which matches the biological half-life of the observed process. The 68Ge/68Ga radionuclide generator makes the PET-nuclide anywhere available without an on-site cyclotron. Besides the perfect availability 68Ga shows well suited nuclide properties for PET, but it has to be co-ordinated by a chelator to introduce it in a radiopharmaceuticals.rnHowever, the physical half-life of 68Ga (67.7 min) might limit the spectrum of clinical applications of 68Ga-labelled radiodiagnostics. Furthermore, 68Ga-labelled analogues of endoradiotherapeuticals of longer biological half-live such as 90Y- or 177Lu-labeled peptides and proteins cannot be used to determine individual radiation dosimetry directly. rnThus, radionuclide generator systems providing positron emitting daughters of extended physical half-life are of renewed interest. In this context, generator-derived positron emitters with longer physical half-life are needed, such as 72As (T½ = 26 h) from the 72Se/72As generator, or 44Sc (T½ = 3.97 h) from the 44Ti/44Sc generator.rnIn this thesis the implementation of radioactive gallium-68 and scandium-44 for molecular imaging and nuclear medical diagnosis, beginning with chemical separation and purification of 44Ti as a radionuclide mother, investigation of pilot generators with different elution mode, building a prototype generator, development and investigation of post-processing of the generator eluate, its concentration and further purification, the labeling chemistry under different conditions, in vitro and in vivo studies of labeled compounds and, finally, in vivo imaging experiments are described.