2 resultados para 748
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
A finite-strain study in the Gran Paradiso massif of the Italian Western Alps has been carried out to elucidate whether ductile strain shows a relationship to nappe contacts and to shed light on the nature of the subhorizontal foliation typical of the gneiss nappes in the Alps. The Rf/_ and Fry methods used on feldspar porphyroclasts from 143 augengneiss and 11 conglomerate samples of the Gran Paradiso unit (upper tectonic unit of the Gran Paradiso massif), as well as, 9 augengneiss (Erfaulet granite) and 3 quartzite conglomerate samples from the underlying Erfaulet unit (lower unit of the Gran Paradiso massif), and 1 sample from mica schist. Microstructures and thermobarometric data show that feldspar ductility at temperatures >~450°C occurred only during high-pressure metamorphism, when the rocks were underplated beneath the overriding Adriatic plate. Therefore, the finite-strain data can be related to high-pressure metamorphism in the Alpine subduction zone. The augen gneiss was heterogeneously deformed and axial ratios of the strain ellipse in XZ sections range from 2.1 to 69.8. The long axes of the finite-strain ellipsoids trend W/WNW and the short axes are subvertical associated with a subhorizontal foliation. The strain magnitudes do not increase towards the nappe contacts. Geochemical work shows that the accumulation of finite strain was not associated with any significant volume strain. Hence, the data indicate flattening strain type in the Gran Paradiso unit and constrictional strain type in the Erfaulet unit and prove deviations from simple shear. In addition, electron microprobe work was undertaken to determine if the analysed fabrics formed during high-P metamorphism. The chemistry of phengites in the studied samples suggests that deformation and final structural juxtaposition of the Gran Paradiso unit against the Erfaulet took place during high-pressure metamorphism. On the other hand, nappe stacking occurred early during subduction probably by brittle imbrication and that ductile strain was superimposed on and modified the nappe structure during high-pressure underplating in the Alpine subduction zone. The accumulation of ductile strain during underplating was not by simple shear and involved a component of vertical shortening, which caused the subhorizontal foliation in the Gran Paradiso massif. It is concluded that this foliation formed during thrusting of the nappes onto each other suggesting that nappe stacking was associated with vertical shortening. The primary evidence for this interpretation is an attenuated metamorphic section with high-pressure metamorphic rocks of the Gran Paradiso unit juxtaposed against the Erfaulet unit. Therefore, the exhumation during high-pressure metamorphism in the Alpine subduction zone involved a component of vertical shortening, which is responsible for the subhorizontal foliation within the nappes.
Resumo:
Applikationsfertige Zytostatikazubereitungen werden heute unter der Verantwortung eines Apothekers in zentralisierten Herstellungsbereichen hergestellt. Weil die Verordnung der Chemotherapie ein großes Fehlerrisiko birgt, ist konsequentes Verordnungsmonitoring ein wesentlicher Teilprozess der zentralen Zytostatikazubereitung. rnDie aktuelle Umsetzung und die Ergebnisse des Verordnungsmonitorings in den Universitätskliniken Deutschlands wurden im Rahmen dieser Arbeit in einer prospektiven Erhebung erfasst. Als häufigste Verordnungsirrtümer wurden Dosisberechnungsfehler (48%), welche als von hoher Relevanz (78%) für die Patientensicherheit angesehen wurden, genannt. Die Inzidenz der Verordnungsfehler betrug durchschnittlich 0,77% bei rund 1950 Verordnungen pro Tag. Das konsequente Verordnungsmonitoring von pharmazeutischer Seite erfolgt höchst effizient und leistet einen hohen Beitrag zur Patienten- und Arzneimitteltherapiesicherheit in der Onkologie.rnFür die Herstellung der applikationsfertiger Zytostatika-Zubereitungen sind fundierte Kenntnisse zu deren physikalisch-chemischen Stabilität erforderlich. Zu neu zugelassenen Zytostatika und insbesondere Biologicals, stehen häufig noch keine Daten zur Stabilität der applikationsfertigen Lösungen zur Verfügung. Die Bestimmung der physikalisch-chemischen Stabilität war daher Gegenstand dieser Arbeit. Die applikationsfertigen Infusionslösungen der Purin-Analoga Nelarabin und Clofarabin (RP-HPLC), sowie des monoklonalen Antiköpers Trastuzumab (SEC, UV-Spektroskopie, SDS-Page), erwiesen sich über einen Zeitraum von mindestens 28 Tagen als stabil. Die Stabilität zweier Camptothecin-Derivate (Topotecan und Irinotecan) beladen auf DC Beads™, wie auch die Ladungskapazität und Kompatibilität mit Kontrastmitteln, wurde ebenfalls bewiesen. rn