2 resultados para 200404 Laboratory Phonetics and Speech Science

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characteristics of aphasics’ speech in various languages have been the core of numerous studies, but Arabic in general, and Palestinian Arabic in particular, is still a virgin field in this respect. However, it is of vital importance to have a clear picture of the specific aspects of Palestinian Arabic that might be affected in the speech of aphasics in order to establish screening, diagnosis and therapy programs based on a clinical linguistic database. Hence the central questions of this study are what are the main neurolinguistic features of the Palestinian aphasics’ speech at the phonetic-acoustic level and to what extent are the results similar or not to those obtained from other languages. In general, this study is a survey of the most prominent features of Palestinian Broca’s aphasics’ speech. The main acoustic parameters of vowels and consonants are analysed such as vowel duration, formant frequency, Voice Onset Time (VOT), intensity and frication duration. The deviant patterns among the Broca’s aphasics are displayed and compared with those of normal speakers. The nature of deficit, whether phonetic or phonological, is also discussed. Moreover, the coarticulatory characteristics and some prosodic patterns of Broca’s aphasics are addressed. Samples were collected from six Broca’s aphasics from the same local region. The acoustic analysis conducted on a range of consonant and vowel parameters displayed differences between the speech patterns of Broca’s aphasics and normal speakers. For example, impairments in voicing contrast between the voiced and voiceless stops were found in Broca’s aphasics. This feature does not exist for the fricatives produced by the Palestinian Broca’s aphasics and hence deviates from data obtained for aphasics’ speech from other languages. The Palestinian Broca’s aphasics displayed particular problems with the emphatic sounds. They exhibited deviant coarticulation patterns, another feature that is inconsistent with data obtained from studies from other languages. However, several other findings are in accordance with those reported from various other languages such as impairments in the VOT. The results are in accordance with the suggestions that speech production deficits in Broca’s aphasics are not related to phoneme selection but rather to articulatory implementation and some speech output impairments are related to timing and planning deficits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.