54 resultados para Spin Polarization
Resumo:
The use of Magnetic Resonance Imaging (MRI) as a diagnostic tool is increasingly employing functional contrast agents to study or contrast entire mechanisms. Contrast agents in MRI can be classified in two categories. One type of contrast agents alters the NMR signal of the protons in its surrounding, e.g. lowers the T1 relaxation time. The other type enhances the Nuclear Magnetic Resonance (NMR) signal of specific nuclei. For hyperpolarized gases the NMR signal is improved up to several orders of magnitude. However, gases have a high diffusivity which strongly influences the NMR signal strength, hence the resolution and appearance of the images. The most interesting question in spatially resolved experiments is of course the achievable resolution and contrast by controlling the diffusivity of the gas. The influence of such diffusive processes scales with the diffusion coefficient, the strength of the magnetic field gradients and the timings used in the experiment. Diffusion may not only limit the MRI resolution, but also distort the line shape of MR images for samples, which contain boundaries or diffusion barriers within the sampled space. In addition, due to the large polarization in gaseous 3He and 129Xe, spin diffusion (different from particle diffusion) could play a role in MRI experiments. It is demonstrated that for low temperatures some corrections to the NMR measured diffusion coefficient have to be done, which depend on quantum exchange effects for indistinguishable particles. Physically, if these effects can not change the spin current, they can do it indirectly by modifying the velocity distribution of the different spin states separately, so that the subsequent collisions between atoms and therefore the diffusion coefficient can eventually be affected. A detailed study of the hyperpolarized gas diffusion coefficient is presented, demonstrating the absence of spin diffusion (different from particle diffusion) influence in MRI at clinical conditions. A novel procedure is proposed to control the diffusion coefficient of gases in MRI by admixture of inert buffer gases. The experimental measured diffusion agrees with theoretical simulations. Therefore, the molecular mass and concentration enter as additional parameters into the equations that describe structural contrast. This allows for setting a structural threshold up to which structures contribute to the image. For MRI of the lung this allows for images of very small structural elements (alveoli) only, or in the other extreme, all airways can be displayed with minimal signal loss due to diffusion.
Resumo:
Virtual Compton Scattering (VCS) is an important reaction for understanding nucleon structure at low energies. By studying this process, the generalized polarizabilities of the nucleon can be measured. These observables are a generalization of the already known polarizabilities and will permit theoretical models to be challenged on a new level. More specifically, there exist six generalized polarizabilities and in order to disentangle them all, a double polarization experiment must be performed. Within this work, the VCS reaction p(e,e p)gamma was measured at MAMI using the A1 Collaboration three spectrometer setup with Q2=0.33 (GeV/c)2. Using the highly polarized MAMI beam and a recoil proton polarimeter, it was possible to measure both the VCS cross section and the double polarization observables. Already in 2000, the unpolarized VCS cross section was measured at MAMI. In this new experiment, we could confirm the old data and furthermore the double polarization observables were measured for the first time. The data were taken in five periods between 2005 and 2006. In this work, the data were analyzed to extract the cross section and the proton polarization. For the analysis, a maximum likelihood algorithm was developed together with the full simulation of all the analysis steps. The experiment is limited by the low statistics due mainly to the focal plane proton polarimeter efficiency. To overcome this problem, a new determination and parameterization of the carbon analyzing power was performed. The main result of the experiment is the extraction of a new combination of the generalized polarizabilities using the double polarization observables.
Resumo:
Covalent grafting mesogenic groups to the coordination cores of the parent mononuclear low-spin and spin-crossover compounds afforded metallomesogenic complexes of iron(II). In comparison with the parent complexes the spin-crossover properties of the alkylated derivatives are substantially modified. The type of the modification was found to be dependent on the properties of the parent system and the nature of the used anion, however, the general tendency is the destabilization of the low-spin state at the favor of spin-crossover or high-spin behavior below 400 K. The structural insight revealed the micro-segregated layered organization. The effect of the alkylation of the parent compounds consists first of all in the change of the lattice to a two-dimensional lamellar one retaining significant intermolecular contacts only within the ionic bilayers. The comprehensive analysis of the structural and thermodynamic data in the homologous series pointed at the mechanism of the interplay between the structural modification on melting and the induced anomalous change of the magnetic properties. A family of one-dimensional spin-crossover polymers was synthesized and characterized using a series of spectroscopic methods, X-ray powder diffraction, magnetic susceptibility measurements and differential scanning calorimetry. The copper analogue of was also synthesized and its crystal structure solved. In comparison with the mononuclear systems, the polymeric mesogens of iron(II) are less sensitive to the glass transition, which was attributed to the moderate concomitant variation of the structure. Nevertheless, the observed increase of the magnetic hysteresis with lengthening of the alkyl substituents was ascribed to the interplay of the structural reorganization of the coordination core due to spin-crossover with the structural delay in the spatial reorganization of the mesogenic substituents. The classification of mononuclear and polymeric metallomesogens according to the interactions between the structural- and the spin-transition and analysis of the data on the reported spin-crossover metallomesogens led to the separation of three types, namely: Type i: systems with coupling between the electronic structure of the iron(II) ions and the mesomorphic behavior of the substance; Type ii: systems where both transitions coexist in the same temperature region but are not coupled due to competition with the dehydration or due to negligible structural transformation; Type iii: systems where both transitions occur in different temperature regions and therefore are uncoupled. Fine-tuning, in particular regarding the temperature at which the spin-transition occurs with hysteresis properties responsible for the memory effect, are still a major challenge towards practical implementation of spin-crossover materials. A possible answer to the problem could be materials in which the spin-crossover transition is coupled with another transition easily controllable by external stimuli. In the present thesis we have shown the viability of the approach realized in the mesogenic systems with coupled phase- and spin-transitions.
Resumo:
The main concern of the A4 parity violation experiment at the Mainzer Microtron accelerator facility is to study the electric and magnetic contributions of strange quarks to the charge and magnetism of the nucleons at the low momentum transfer region. More precisely, the A4 collaboration investigates the strange quarks' contribution to the electric and magnetic vector form factors of the nucleons. Thus, it is important that the A4 experiment uses an adequate and precise non-destructive online monitoring tool for the electron beam polarization when measuring single spin asymmetries in elastic scattering of polarized electrons from unpolarized nucleons. As a consequence, the A4 Compton backscattering polarimeter was designed and installed such that we can take the absolute measurement of the electron beam polarization without interruption to the parity violation experiment. The present study shows the development of an electron beam line that is called the chicane for the A4 Compton backscattering polarimeter. The chicane is an electron beam transport line and provides an interaction region where the electron beam and the laser beam overlap. After studying the properties of beam line components carefully, we developed an electron beam control system that makes a beam overlap between the electron beam and the laser beam. Using the system, we can easily achieve the beam overlap in a short time. The electron control system, of which the performance is outstanding, is being used in production beam times. And the study presents the development of a scintillating fiber electron detector that reduces the statistical error in the electron polarization measurement. We totally redesigned the scintillating fiber detector. The data that were taken during a 2008 beam time shows a huge background suppression, approximately 80 percent, while leaving the Compton spectra almost unchanged when a coincidence between the fiber detector and the photon detector is used. Thus, the statistical error of the polarization measurement is reduced by about 40 percent in the preliminary result. They are the significant progress in measuring a degree of polarization of the electron beam.
Resumo:
Am COMPASS-Experiment am CERN-SPS wird die Spinsstruktur des Nukleons mit Hilfe der Streuung von polarisierten Myonen an polarisierten Nukleonen untersucht. Der in der inklusiven tiefinelastischen Streuung gemessene Beitrag der Quarks zum Nukleonspin reicht nicht aus, um den Spin des Nukleons zu erklären. Daher soll geklärt werden, wie die Gluonpolarisation und die Bahndrehimpulse von Quarks und Gluonen zum Gesamtspin des Nukleons beitragen. Da sich die Gluonpolarisation aus der $Q^{2}$-Abhängigkeit der Asymmetrien in der inklusiven Streuung nur abschätzen lässt, wird eine direkte Messung der Gluonpolarisation benötigt. Die COMPASS-Kollaboration bestimmt daher die Wirkungsquerschnittsasymmetrien für Photon-Gluon-Fusionprozesse, indem sie zum einen die offene Charmproduktion und zum anderen die Produktion von Hadronpaaren mit großen Transversalimpulsen verwendet. In dieser Arbeit wird die Messung der Gluonpolarisation mit den COMPASS-Daten der Jahre 2003 und 2004 vorgestellt. Für die Analyse werden die Ereignisse mit großem Impulsübertrag ($Q^{2}>1$ $GeV^{2}/c^{2}$) und mit Hadronpaaren mit großem Transversalimpuls ($p_{perp}>0.7$ $GeV/c$) verwendet. Die Photon-Nukleon-Asymmetrie wurde aus dem gewichteten Doppelverhältnis der selektierten Ereignisse bestimmt. Der Schnitt auf $p_{perp}>0.7$rn$GeV/c$ unterdrückt die Prozesse führender Ordnung und QCD-Compton Prozesse, so dass die Asymmetrie direkt mit der Gluonpolarisation über die Analysierstärke verknüpft ist. Der gemessene Wert ist sehr klein und verträglich mit einer verschwindenden Gluonpolarisation. Zur Vermeidung von falschen Asymmetrien aufgrund der Änderung der Detektorakzeptanz wurden Doppelverhältnisse untersucht, bei denen sich der Wirkungsquerschnitt aufhebt und nur die Detektorasymmetrien übrig bleiben. Es konnte gezeigt werden, dass das COMPASS-Spektrometer keine signifikante Zeitabhängigkeit aufweist. Für die Berechnung der Analysierstärke wurden Monte Carlo Ereignisse mit Hilfe des LEPTO-Generators und des COMGeant Software Paketes erzeugt. Dabei ist eine gute Beschreibung der Daten durch das Monte Carlo sehr wichtig. Dafür wurden zur Verbesserung der Beschreibung JETSET Parameter optimiert. Es ergab sich ein Wert von rn$frac{Delta G}{G}=0.054pm0.145_{(stat)}pm0.131_{(sys)}pm0.04_{(MC)}$ bei einem mittleren Impulsbruchteil von $langle x_{gluon}rangle=0.1$ und $langle Q^{2}rangle=1.9$ $GeV^{2}/c^{2}$. Dieses Ergebnis deutet auf eine sehr kleine Gluonpolarisation hin und steht im Einklang mit den Ergebnissen anderer Methoden, wie offene Charmproduktion und mit den Ergebnissen, die am doppelt polarisierten RHIC Collider am BNL erzielt wurden.
Resumo:
Key technology applications like magnetoresistive sensors or the Magnetic Random Access Memory (MRAM) require reproducible magnetic switching mechanisms. i.e. predefined remanent states. At the same time advanced magnetic recording schemes push the magnetic switching time into the gyromagnetic regime. According to the Landau-Lifschitz-Gilbert formalism, relevant questions herein are associated with magnetic excitations (eigenmodes) and damping processes in confined magnetic thin film structures.rnObjects of study in this thesis are antiparallel pinned synthetic spin valves as they are extensively used as read heads in today’s magnetic storage devices. In such devices a ferromagnetic layer of high coercivity is stabilized via an exchange bias field by an antiferromagnet. A second hard magnetic layer, separated by a non-magnetic spacer of defined thickness, aligns antiparallel to the first. The orientation of the magnetization vector in the third ferromagnetic NiFe layer of low coercivity - the freelayer - is then sensed by the Giant MagnetoResistance (GMR) effect. This thesis reports results of element specific Time Resolved Photo-Emission Electron Microscopy (TR-PEEM) to image the magnetization dynamics of the free layer alone via X-ray Circular Dichroism (XMCD) at the Ni-L3 X-ray absorption edge.rnThe ferromagnetic systems, i.e. micron-sized spin valve stacks of typically deltaR/R = 15% and Permalloy single layers, were deposited onto the pulse leading centre stripe of coplanar wave guides, built in thin film wafer technology. The ferromagnetic platelets have been applied with varying geometry (rectangles, ellipses and squares), lateral dimension (in the range of several micrometers) and orientation to the magnetic field pulse to study the magnetization behaviour in dependence of these magnitudes. The observation of magnetic switching processes in the gigahertz range became only possible due to the joined effort of producing ultra-short X-ray pulses at the synchrotron source BESSY II (operated in the so-called low-alpha mode) and optimizing the wave guide design of the samples for high frequency electromagnetic excitation (FWHM typically several 100 ps). Space and time resolution of the experiment could be reduced to d = 100 nm and deltat = 15 ps, respectively.rnIn conclusion, it could be shown that the magnetization dynamics of the free layer of a synthetic GMR spin valve stack deviates significantly from a simple phase coherent rotation. In fact, the dynamic response of the free layer is a superposition of an averaged critically damped precessional motion and localized higher order spin wave modes. In a square platelet a standing spin wave with a period of 600 ps (1.7 GHz) was observed. At a first glance, the damping coefficient was found to be independent of the shape of the spin-valve element, thus favouring the model of homogeneous rotation and damping. Only by building the difference in the magnetic rotation between the central region and the outer rim of the platelet, the spin wave becomes visible. As they provide an additional efficient channel for energy dissipation, spin waves contribute to a higher effective damping coefficient (alpha = 0.01). Damping and magnetic switching behaviour in spin valves thus depend on the geometry of the element. Micromagnetic simulations reproduce the observed higher-order spin wave mode.rnBesides the short-run behaviour of the magnetization of spin valves Permalloy single layers with thicknesses ranging from 3 to 40 nm have been studied. The phase velocity of a spin wave in a 3 nm thick ellipse could be determined to 8.100 m/s. In a rectangular structure exhibiting a Landau-Lifschitz like domain pattern, the speed of the field pulse induced displacement of a 90°-Néel wall has been determined to 15.000 m/s.rn
Resumo:
Enhancing the sensitivity of nuclear magnetic resonance measurements via hyperpolarization techniques like parahydrogen induced polarization (PHIP) is of high interest for spectroscopic investigations. Parahydrogen induced polarization is a chemical method, which makes use of the correlation between nuclear spins in parahydrogen to create hyperpolarized molecules. The key feature of this technique is the pairwise and simultaneous transfer of the two hydrogen atoms of parahydrogen to a double or triple bond resulting in a population of the Zeeman energy levels different from the Boltzmann equation. The obtained hyperpolarization results in antiphase peaks in the NMR spectrum with high intensities. Due to these strong NMR signals, this method finds arnlot of applications in chemistry e.g. the characterization of short-lived reaction intermediates. Also in medicine it opens up the possibility to boost the sensitivity of medical diagnostics via magnetic labeling of active contrast agents. Thus, further examination and optimization of the PHIP technique is of significant importance in order to achieve the highest possible sensitivity gain.rnrnIn this work, different aspects concerning PHIP were studied with respect to its chemical and spectroscopic background. The first part of this work mainly focused on optimizing the PHIP technique by investigating different catalyst systems and developing new setups for the parahydrogenation. Further examinations facilitated the transfer of the generated polarization from the protons to heteronuclei like 13C. The second part of this thesis examined the possibility to transfer these results to different biologically active compounds to enable their later application in medical diagnostics. Onerngroup of interesting substances is represented by metabolites or neurotransmitters in mammalian cells. Other interesting substances are clinically relevant drugs like a barbituric acid derivative or antidepressant drugs like citalopram which were investigated with regard to their applicability for the PHIP technique and the possibility to achievernpolarization transfer to 13C nuclei. The last investigated substrate is a polymerizable monomer whose polymer was used as a blood plasma expander for trauma victims after the first half of the 20th century. In this case, the utility of the monomer for the PHIP technique as a basis for later investigations of a polymerization reaction using hyperpolarized monomers was examined.rnrnHence, this thesis covers the optimization of the PHIP technology, hereby combining different fields of research like chemical and spectroscopical aspects, and transfers the results to applications of real biologally acitve compounds.
Resumo:
In this thesis, the self-assembled functional structure of a broad range of amphiphilic molecular transporters is studied. By employing paramagnetic probe molecules and ions, continuous-wave and pulse electron paramagnetic resonance spectroscopy reveal information about the local structure of these materials from the perspective of incorporated guest molecules. First, the transport function of human serum albumin for fatty acids is in the focus. As suggested by the crystal structure, the anchor points for the fatty acids are distributed asymmetrically in the protein. In contrast to the crystallographic findings, a remarkably symmetric entry point distribution of the fatty acid binding channels is found, which may facilitate the uptake and release of the guest molecules. Further, the metal binding of 1,2,3-triazole modified star-shaped cholic acid oligomers is studied. These biomimetic molecules are able to include and transport molecules in solvents of different polarity. A pre-arrangement of the triazole groups induces a strong chelate-like binding and close contact between guest molecule and metal ion. In absence of a preordering, each triazole moiety acts as a single entity and the binding affinity for metal ions is strongly decreased. Hydrogels based on N-isopropylacrylamide phase separate from water above a certain temperature. The macroscopic thermal collapse of these hydrogels is utilized as a tool for dynamic nuclear polarization. It is shown that a radical-free hyperpolarized solution can be achieved with a spin-labeled gel as separable matrix. On the nanoscale, these hydrogels form static heterogeneities in both structure and function. Collapsed regions protect the spin probes from a chemical decay while open, water-swollen regions act as catalytic centers. Similarly, thermoresponsive dendronized polymers form structural heterogeneities, which are, however, highly dynamic. At the critical temperature, they trigger the aggregation of the polymer into mesoglobules. The dehydration of these aggregates is a molecularly controlled non-equilibrium process that is facilitated by a hydrophobic dendritic core. Further, a slow heating rate results in a kinetically entrapped non-equilibrium state due to the formation of an impermeable dense polymeric layer at the periphery of the mesoglobule.
Resumo:
Das A4-Experiment bestimmt den Beitrag der Strangequarks zu den elektromagnetischen Formfaktoren des Nukleons durch Messung der Paritätsverletzung in der elastischen Elektron-Nukleon-Streuung. Diese Messungen werden mit dem spinpolarisierten Elektronenstrahl des Mainzer Mikrotrons (MAMI) bei Strahlenergien zwischen 315 und 1508 MeV ndurchgeführt. Die Bestimmung des Strahlpolarisationsgrades ist für die Analyse der Daten unerläßlich, um die physikalische Asymmetrie aus der gemessenen paritätsverletzenden Asymmetrie extrahieren zu können. Aus diesem Grund wird von der A4-Kollaboration ein neuartiges Compton-Laserrückstreupolarimeter entwickelt, das eine zerstörungsfreie Messung der Strahlpolarisation, parallel zum laufenden Paritätsexperiment erlaubt. Um den zuverlässigen Dauerbetrieb des Polarimeters zu ermöglichen, wurde das Polarimeter im Rahmen dieser Arbeit weiterentwickelt. Das Datenerfassungssystem für Photonen- und Elektronendetektor wurde neu aufgebaut und im Hinblick auf die Verarbeitung hoher Raten optimiert. Zum Nachweis der rückgestreuten Photonen wurde ein neuartiger Detektor (LYSO) in Betrieb genommen. Darüber hinaus wurden GEANT4-Simulationen der Detektoren durchgeführt und eine Analyseumgebung für die Extraktion von Comptonasymmetrien aus den Rückstreudaten entwickelt. Das Analyseverfahren nutzt die Möglichkeit, die rückgestreuten Photonen durch koinzidente Detektion der gestreuten Elektronen energiemarkiert nachzuweisen (Tagging). Durch die von der Energiemarkierung eingeführte differentielle Energieskala wird somit eine präzise Bestimmung der Analysierstärke möglich. In der vorliegenden Arbeit wurde die Analysierstärke des Polarimeters bestimmt, so daß nun das Produkt von Elektronen- und Laserstrahlpolarisation bei einem Strahlstrom von 20 muA, parallel zum laufenden Paritätsexperiment, mit einer statistischen Genauigkeit von 1% in 24 Stunden bei 855 MeV bzw. <1% in 12 Stunden bei 1508 MeV gemessen werden kann. In Kombination mit der Bestimmung der Laserpolarisation in einer parallelen Arbeit (Y. Imai) auf 1% kann die statistische Unsicherheit der Strahlpolarisation im A4-Experiment von zuvor 5% auf nun 1,5% bei 1508MeV verringert werden. Für die Daten zur Messung der paritätsverletzenden Elektronenstreuung bei einem Viererimpulsübertrag von $Q^2=0,6 (GeV/c)^2$ beträgt die Rohasymmetrie beim derzeitigen Stand der Analyse $A_{PV}^{Roh} = ( -20,0 pm 0,9_{stat} ) cdot 10^{-6}$. Für eine Strahlpolarisation von 80% erhält man einen Gesamtfehler von $1,68 cdot 10^{-6}$ für $Delta P_e/P_e = 5 %$. Als Ergebnis dieser Arbeit wird sich dieser Fehler durch Analyse der Daten des Compton-Laserrückstreupolarimeters um 29% auf $1,19 cdot 10^{-6}$ ($Delta P_e/P_e = 1,5 %$) verringern lassen.
Resumo:
Collinear laser spectroscopy has been used as a tool for nuclear physics for more than 30 years. The unique possibility to extract nuclear properties like spins, radii and nuclear moments in a model-independent manner leads to important physics results to test the predictive power of existing nuclear models. rnThis work presents the construction and the commissioning of a new collinear laser spectroscopy experiment TRIGA-LASER as a part of the TRIGA-SPEC facility at the TRIGA research reactor at the University of Mainz. The goal of the experiment is to study the nuclear structure of radioactive isotopes which will be produced by neutron-induced fission near the reactor core and transported to an ion source by a gas jet system. rnThe versatility of the collinear laser spectroscopy technique will be exploited in the second part of this thesis. The nuclear spin and the magnetic moment of the neutron-deficient isotope Mg-21 will be presented, which were measured by the detection of the beta-decay asymmetry induced by nuclear polarization after optical pumping. A combination of this detection method with the classical fluorescence detection is then used to determine the isotope shifts of the neutron-rich magnesium isotopes from Mg-24 through Mg-32 to study the transition to the ''island of inversion''.
Resumo:
Durch die Möglichkeit, gleichzeitig mehrere Polarisationsfreiheitsgradernin der quasi-elastischen Elektronstreuung an $^3mathrm{He}$ zurnmessen, bietet sich ein neuer experimenteller Zugang zu kleinen, aber rnwichtigen Partialwellenbeiträgen ($S'$, $D$-Welle) desrn$^3mathrm{He}$-Grundzustands. Dies ermöglicht nicht nur ein tieferesrnVerständnis des Drei-Körper-Systems, sondern bietet auch diernMöglichkeit, Erkenntnisse über die $^3mathrm{He}$-Struktur undrnDynamik zu erlangen. Mit Hilfe dieser Informationen lassen sich abrninitio Rechnungen testen, sowie Korrekturen berechnen, die für anderernExperimente (z.B. Messung von $G_{en}$) benötigt werden. rnrnModerne Faddeev-Rechnungen liefern nicht nur eine quantitativernBeschreibung des $^3mathrm{He}$-Grundzustands, sondern geben auchrneinen Einblick in die sogenannten spinabhängigenrnImpulsverteilungen. Eine gründliche experimentelle Untersuchung ist in rndiesem Zusammenhang nötig, um eine solide Basis für die Üperprüfungrnder theoretische Modelle zu liefern. EinrnDreifach-Polarisationsexperiment liefert hier zum einen wichtigernDaten, zum anderen kann damit untersucht werden, ob mit der Methoderndes glqq Deuteron-Tagginggrqq polarisiertes $^3mathrm{He}$ alsrneffektives polarisiertes Protonentarget verwendet werden kann. rnrnDas hier vorgestellte Experiment kombiniert erstmals Strahl- undrnTargetpolarisation sowie die Messung der Polarisation des auslaufendenrnProtons. Das Experiment wurde im Sommer 2007 an derrnDrei-Spektrometer-Anlage der A1-Kollaboration an MAMI rndurchgeführt. Dabei wurde mit einer Strahlenergie vonrn$E=855,mathrm{MeV}$ bei $q^2=-0,14,(mathrm{GeV/c})^2$rn$(omega=0,13,mathrm{GeV}$, $q=0,4,mathrm{GeV/c})$ gemessen.rnrnDie bestimmten Wirkungsquerschnitte, sowie die Strahl-Target- und diernDreifach-Asymmetrie werden mit theoretischen Modellrechnungen vonrnJ. Golak (Plane Wave Impuls Approximation PWIA, sowie ein Modell mitrnEndzustandswechselwirkung) verglichen. Zudem wurde das Modell von dernForest verwendet, welches den Wirkungsquerschnitt über eine gemessenernSpektralfunktion berechnet. Der Vergleich mit den Modellrechnungenrnzeigt, dass sowohl der Wirkungsquerschnitt, als auch die Doppel- undrnDreifach-Asymmetrie gut mit den theoretischen Rechnungenrnübereinstimmen. rnrnDie Ergebnisse dieser Arbeit bestätigen, dass polarisiertesrn$^3mathrm{He}$ nicht nur als polarisiertes Neutronentarget, sondernrndurch Nachweis des Deuterons ebenfalls als polarisiertesrnProtonentarget verwendet werden kann.
Resumo:
In dieser Arbeit wurden dünne Schichten von Heusler-Verbindungen hergestellt und auf ihre Transporteigenschaften hin untersucht.rnDer Anomale Hall-Effekt (AHE) ist dabei von besonderem Interesse. Er ist ein seit langer Zeit bekannter, jedoch noch nicht vollständig verstandener Transport-Effekt. Die meisten Veröffentlichungen theoretischer Arbeiten konzentrieren sich auf den Einfluss eines bestimmten Beitrags zum AHE. Tatsächlich gemessene experimentelle Daten können jedoch oft nicht in Einklang mit idealisierten Annahmen gebracht werden. rnDie vorliegende Arbeit diskutiert die Ergebnisse, welche aus Messungen von Materialien mit niedrigem Restwiderstand erhalten wurden. rnrnAls prototypische Materialien wurden hier hyphenation Heusler-Verbindungen untersucht. Als Material mit einer komplexen Topologie der Fermi-Fläche zeichnet sich dort der Einfluss von Defekten und der Unordnung der Kristallstruktur deutlich ab.rnrnDurch Verwendung von Filmen mit unterschiedlichem Grad der Unordnung können verschiedene Streumechanismen unterschieden werden. Für Co$_{2}$FeSi$_{0.6}$Al$_{0.4}$ and Co$_{2}$FeGa$_{0.5}$Ge$_{0.5}$ zeigt sich ein positiver AHE bei einer Unordnung vom Typ B2 und bei einer induzierten temperaturabh"angigen Streuung, wo hingegen eine Typ DO$_{3}$-Unordnung zusammen mit anderen möglichen intrinsischen Beiträgen einen negativen Effekt hervorruft.rnrnDarüber hinaus wurden die magneto-optische Kerr-Effekte (MOKE) dieser Verbindungen untersucht. Hierfür wurden Beiträge erster Ordnung als Funktion der intrinsischen und extrinsischen Parameter qualitativ analysiert. Auf den Einfluss der kristallinen Ordnung auf Beiträge zweiter Ordnung des MOKE-Signals wird ebenfalls eingegangen.rnrnDes Weiteren wurden dünne Schichten der Heusler-Verbindung Co$_{2}$MnAl auf MgO- und Si-Subs-traten (beide (100)) mit Hochfrequenz-Mag-netron-Sputtern erzeugt. Die zusammensetzung sowie die magnetischen und Transport-Eigenschaften wurden hinsichtlich unterschiedlicher Abscheidebedingungen systematisch untersucht.rnrnInsbesondere zeigt der AHE-Widerstand ein außerordentliches temperaturunabhängiges Verhalten in einem Bereich moderater Magnetfeldstärken von 0 bis 0.6,T. Hierf"ur wurde der nicht-diagonale Transport bei Temperaturen bis zu 300,$^{circ}$C analysiert. Die Daten zeigen die Eignung des Materials für Hall-Sensoren auch oberhalb der Raumtemperatur.rnrnJüngst wurde der Spin Seebeck-Effekt (SSE) entdeckt. Der Effekt aus dem Bereich der Spin-Kaloritronik erzeugt eine Spin-Spannung'' aufgrund eines Temperaturgradienten in magnetischen Materialien. Hier werden vorläufige Messungen des SSE in Ni$_{80}$Fe$_{20}$ und in Heusler-Verbindungen präsentiert.rn
Resumo:
Die vorliegende Doktorarbeit befasst sich mit klassischen Vektor-Spingläsern eine Art von ungeordneten Magneten - auf verschiedenen Gittertypen. Da siernbedeutsam für eine experimentelle Realisierung sind, ist ein theoretisches Verständnis von Spinglas-Modellen mit wenigen Spinkomponenten und niedriger Gitterdimension von großer Bedeutung. Da sich dies jedoch als sehr schwierigrnerweist, sind neue, aussichtsreiche Ansätze nötig. Diese Arbeit betrachtet daher den Limesrnunendlich vieler Spindimensionen. Darin entstehen mehrere Vereinfachungen im Vergleichrnzu Modellen niedriger Spindimension, so dass für dieses bedeutsame Problem Eigenschaften sowohl bei Temperatur Null als auch bei endlichen Temperaturenrnüberwiegend mit numerischen Methoden ermittelt werden. Sowohl hyperkubische Gitter als auch ein vielseitiges 1d-Modell werden betrachtet. Letzteres erlaubt es, unterschiedliche Universalitätsklassen durch bloßes Abstimmen eines einzigen Parameters zu untersuchen. "Finite-size scaling''-Formen, kritische Exponenten, Quotienten kritischer Exponenten und andere kritische Größen werden nahegelegt und mit numerischen Ergebnissen verglichen. Eine detaillierte Beschreibung der Herleitungen aller numerisch ausgewerteter Gleichungen wird ebenso angegeben. Bei Temperatur Null wird eine gründliche Untersuchung der Grundzustände und Defektenergien gemacht. Eine Reihe interessanter Größen wird analysiert und insbesondere die untere kritische Dimension bestimmt. Bei endlicher Temperatur sind der Ordnungsparameter und die Spinglas-Suszeptibilität über die numerisch berechnete Korrelationsmatrix zugänglich. Das Spinglas-Modell im Limes unendlich vieler Spinkomponenten kann man als Ausgangspunkt zur Untersuchung der natürlicheren Modelle mit niedriger Spindimension betrachten. Wünschenswert wäre natürlich ein Modell, das die Vorteile des ersten mit den Eigenschaften des zweiten verbände. Daher wird in Modell mit Anisotropie vorgeschlagen und getestet, mit welchem versucht wird, dieses Ziel zu erreichen. Es wird auf reizvolle Wege hingewiesen, das Modell zu nutzen und eine tiefergehende Beschäftigung anzuregen. Zuletzt werden sogenannte "real-space" Renormierungsgruppenrechnungen sowohl analytisch als auch numerisch für endlich-dimensionale Vektor-Spingläser mit endlicher Anzahl von Spinkomponenten durchgeführt. Dies wird mit einer zuvor bestimmten neuen Migdal-Kadanoff Rekursionsrelation geschehen. Neben anderen Größen wird die untere kritische Dimension bestimmt.
Resumo:
Die Messung eines möglichen elektrischen Dipolmoments des freien Neutrons erfordert genaustmögliche Kenntnis und Überwachung des magnetischen Feldes im Inneren der n2EDM-Spektrometerkammer. Die freie Spinpräzession von hyperpolarisiertem ³He kann verbunden mit einer Signalauslese mittels optisch gepumpter Cs-Magnetometer dazu genutzt werden, Messempfindlichkeit auf Magnetfeldschwankungen im Bereich weniger Femto-Tesla zu erhalten. Am Institut für Physik der Universität Mainz wurde eine ³He/Cs-Testanlage aufgebaut, um die Möglichkeiten der Signalauslese der ³He-Spinpräzession mittels eines lampengepumpten Cs-Magnetometers zu untersuchen. Darüber hinaus wurde eine ultrakompakte und transportable Polarisationseinheit entwickelt und installiert, welche ermöglicht, eine ³He-Hyperpolarisation von bis zu 55 Prozent zu erreichen. Im Anschluss wird das polarisierte 3He-Gas automatisiert komprimiert und in zwei Magnetometerzellen in Sandwichanordnung innerhalb der n2EDM-Spektrometerkammer gefüllt. In dieser Arbeit werden die Ergebnisse der ersten im Januar 2012 erfolgreich durchgeführten Messungen vorgestellt. Bei diesen Messungen wurde ³He-Gas in der ultrakompakten Polarisationseinheit hyperpolarisiert und über Führungsfelder eines Transfersystems in eine vierlagige Mumetall-Abschirmung transferiert. Im Anschluss konnte im Inneren der magnetischen Abschirmung die freie ³He-Spinpräzession mittels eines lampengepumpten Cs-Magnetometer eindeutig nachgewiesen werden.
Resumo:
A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for 1H, the most widely used nucleus in NMR andrnMRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones.Here, I describe a method giving rise to high 1H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences.rnrnHyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization.These two achievements open up alternative opportunities to use the standard MRI nucleus 1H for e.g. metabolic imaging in the future.