5 resultados para Microfluidic Analytical Techniques

em AMS Tesi di Laurea - Alm@DL - Universit


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent times, the choices of consumers have been more conscious and oriented to foods with health benefits. The present paper deals with the study of oil from crushing of olive and huzelnut with the aim of obtaining a “functional food”. Different samples of oil derived from the crushing of olive (O), olive with 5% of hazelnut (O5N) and olive with 10% of hazelnut (O10N), exposed to different temperatures (28 and 35°C) and times (15 and 30 minutes) of malaxation. The samples of oil were initially subjected to a qualitative assessment by the analysis of peroxide and free acidity. Following further analyses were carried out namely the determination of fatty acids and triglycerides by FAST GC-FID, the determination of tocopherols by HPLC-FLC, the analysis of sterols by GC/MS and the spectroscopic analysis with FT-MIR combined with statistical analysis with PCA and PLS. The results showed that increasing the time and temperature of malaxation there aren’t relevant significant differences (p<0,05) in the composition of fatty acids, triglycerides and tocopherols in the different oils, but there are higher extraction yields. The increase of content of hazelnut in phase of crushing causes the decrease of triglycerides C50 and C52, the increase of the class C54, total tocopherols and of total sterols as well. The samples analysed with FT-MIR spectroscopy have showed, on the contrary to conventional analytical techniques, a good discrimination between different oils despite of the similar chemical composition of olive and hazelnuts. After the PLS models were built from spectra FT-MIR in order to estimate the content of triglycerides C50, C52 and C54 and total tocopherols, with good R2 in full cross validation (R2>0,821).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Airborne Particulate Matter (PM), can get removed from the atmosphere through wet and dry mechanisms, and physically/chemically interact with materials and induce premature decay. The effect of dry depositions is a complex issue, especially for outdoor materials, because of the difficulties to collect atmospheric deposits repeatable in terms of mass and homogeneously distributed on the entire investigated substrate. In this work, to overcome these problems by eliminating the variability induced by outdoor removal mechanisms (e.g. winds and rainfalls), a new sampling system called ‘Deposition Box’, was used for PM sampling. Four surrogate materials (Cellulose Acetate, Regenerated Cellulose, Cellulose Nitrate and Aluminum) with different surfaces features were exposed in the urban-marine site of Rimini (Italy), in vertical and horizontal orientations. Homogeneous and reproducible PM deposits were obtained and different analytical techniques (IC, AAS, TOC, VP-SEM-EDX, Vis-Spectrophotometry) were employed to characterize their mass, dimension and composition. Results allowed to discriminate the mechanisms responsible of the dry deposition of atmospheric particles on surfaces with different nature and orientation and to determine which chemical species, and in which amount, tend to preferentially deposit on them. This work demonstrated that “Deposition Box” can represent an affordable tool to study dry deposition fluxes on materials and results obtained will be fundamental in order to extend this kind of exposure to actual building and heritage materials, to investigate the PM contribution in their decay.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A relevant problem of polyolefins processing is the presence of volatile and semi-volatile compounds (VOCs and SVOCs) such as linear chains alkanes found out in final products. These VOCs can be detected by customers from the unpleasant smelt and can be an environmental issue, at the same time they can cause negative side effects during process. Since no previously standardized analytical techniques for polymeric matrix are available in bibliography, we have implemented different VOCs extraction methods and gaschromatographic analysis for quali-quantitative studies of such compounds. In literature different procedures can be found including microwave extraction (MAE) and thermo desorption (TDS) used with different purposes. TDS coupled with GC-MS are necessary for the identification of different compounds in the polymer matrix. Although the quantitative determination is complex, the results obtained from TDS/GC-MS show that by-products are mainly linear chains oligomers with even number of carbon in a C8-C22 range (for HDPE). In order to quantify these linear alkanes by-products, a more accurate GC-FID determination with internal standard has been run on MAE extracts. Regardless the type of extruder used, it is difficult to distinguish the effect of the various processes, which in any case entails having a lower-boiling substance content, lower than the corresponding virgin polymer. The two HDPEs studied can be distinguished on the basis of the quantity of analytes found, therefore the production process is mainly responsible for the amount of VOCs and SVOCs observed. The extruder technology used by Sacmi SC allows to obtain a significant reduction in VOCs compared to the conventional screw system. Thus, the result is significantly important as a lower quantity of volatile substances certainly leads to a lower migration of such materials, especially when used for food packaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Graphite is a mineral commodity used as anode for lithium-ion batteries (LIBs), and its global demand is doomed to increase significantly in the future due to the forecasted global market demand of electric vehicles. Currently, the graphite used to produce LIBs is a mix of synthetic and natural graphite. The first one is produced by the crystallization of petroleum by-products and the second comes from mining, which causes threats related to pollution, social acceptance, and health. This MSc work has the objective of determining compositional and textural characteristics of natural, synthetic, and recycled graphite by using SEM-EDS, XRF, XRD, and TEM analytical techniques and couple these data with dynamic Material Flow Analysis (MFA) models, which have the objective of predicting the future global use of graphite in order to test the hypothesis that natural graphite will no longer be used in the LIB market globally. The mineral analyses reveal that the synthetic graphite samples contain less impurities than the natural graphite, which has a rolled internal structure similar to the recycled one. However, recycled graphite shows fractures and discontinuities of the graphene layers caused by the recycling process, but its rolled internal structure can help the Li-ions’ migration through the fractures. Three dynamic MFA studies have been conducted to test distinct scenarios that include graphite recycling in the period 2022-2050 and it emerges that - irrespective of any considered scenario - there will be an increase of synthetic graphite demand, caused by the limited stocks of battery scrap available. Hence, I conclude that both natural and recycled graphite is doomed to be used in the LIB market in the future, at least until the year 2050 when the stock of recycled graphite production will be enough to supersede natural graphite. In addition, some new improvement in the dismantling and recycling processes are necessary to improve the quality of recycled graphite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research project object of this thesis is focused on the development of an advanced analytical system based on the combination of an improved thin layer chromatography (TLC) plate coupled with infrared (FTIR) and Raman microscopies for the detection of synthetic dyes. Indeed, the characterization of organic colorants, which are commonly present in mixtures with other components and in a very limited amount, still represents a challenging task in scientific analyses of cultural heritage materials. The approach provides selective spectral fingerprints for each compound, foreseeing the complementary information obtained by micro ATR-RAIRS-FTIR and SERS-Raman analyses, which can be performed on the same separated spot. In particular, silver iodide (AgI) applied on a gold coated slide is proposed as an efficient stationary phase for the discrimination of complex analyte mixtures, such as dyes present in samples of art-historical interest. The gold-AgI-TLC plate shows high performances related both to the chromatographic separation of analytes and to the spectroscopic detection of components. The use of a mid-IR transparent inorganic salt as the stationary phase avoids interferences of the background absorption in FTIR investigations. Moreover, by ATR microscopy measurements performed on the gold-AgI surface, a considerable enhancement in the intensity of spectra is observed. Complementary information can be obtained by Raman analyses, foreseeing a SERS activity of the AgI substrate. The method has been tested for the characterization of a mixture of three synthetic organic colorants widely used in dyeing processes: Brilliant Green (BG1), Rhodamine B (BV10) and Methylene Blue (BB9).