2 resultados para spectra properties

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray absorption spectroscopy (XAS) is a powerful means of investigation of structural and electronic properties in condensed -matter physics. Analysis of the near edge part of the XAS spectrum, the so – called X-ray Absorption Near Edge Structure (XANES), can typically provide the following information on the photoexcited atom: - Oxidation state and coordination environment. - Speciation of transition metal compounds. - Conduction band DOS projected on the excited atomic species (PDOS). Analysis of XANES spectra is greatly aided by simulations; in the most common scheme the multiple scattering framework is used with the muffin tin approximation for the scattering potential and the spectral simulation is based on a hypothetical, reference structure. This approach has the advantage of requiring relatively little computing power but in many cases the assumed structure is quite different from the actual system measured and the muffin tin approximation is not adequate for low symmetry structures or highly directional bonds. It is therefore very interesting and justified to develop alternative methods. In one approach, the spectral simulation is based on atomic coordinates obtained from a DFT (Density Functional Theory) optimized structure. In another approach, which is the object of this thesis, the XANES spectrum is calculated directly based on an ab – initio DFT calculation of the atomic and electronic structure. This method takes full advantage of the real many-electron final wavefunction that can be computed with DFT algorithms that include a core-hole in the absorbing atom to compute the final cross section. To calculate the many-electron final wavefunction the Projector Augmented Wave method (PAW) is used. In this scheme, the absorption cross section is written in function of several contributions as the many-electrons function of the finale state; it is calculated starting from pseudo-wavefunction and performing a reconstruction of the real-wavefunction by using a transform operator which contains some parameters, called partial waves and projector waves. The aim of my thesis is to apply and test the PAW methodology to the calculation of the XANES cross section. I have focused on iron and silicon structures and on some biological molecules target (myoglobin and cytochrome c). Finally other inorganic and biological systems could be taken into account for future applications of this methodology, which could become an important improvement with respect to the multiscattering approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radial velocities measured from near-infrared (NIR) spectra are a potential tool to search for extrasolar planets around cool stars. High resolution infrared spectrographs now available reach the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph and it is a powerful tool to provide high resolution spectra for accurate radial velocity measurements of exo-planets and for chemical and dynamical studies of stellar or extragalactic objects. No other IR instruments have the GIANO's capability to cover the entire NIR wavelength range. In this work we develop an ensemble of IDL procedures to measure high precision radial velocities on a few GIANO spectra acquired during the commissioning run, using the telluric lines as wevelength reference. In Section 1.1 various exoplanet search methods are described. They exploit different properties of the planetary system. In Section 1.2 we describe the exoplanet population discovered trough the different methods. In Section 1.3 we explain motivations for NIR radial velocities and the challenges related the main issue that has limited the pursuit of high-precision NIR radial velocity, that is, the lack of a suitable calibration method. We briefly describe calibration methods in the visible and the solutions for IR calibration, for instance, the use of telluric lines. The latter has advantages and problems, described in detail. In this work we use telluric lines as wavelength reference. In Section 1.4 the Cross Correlation Function (CCF) method is described. This method is widely used to measure the radial velocities.In Section 1.5 we describe GIANO and its main science targets. In Chapter 2 observational data obtained with GIANO spectrograph are presented and the choice criteria are reported. In Chapter 3 we describe the detail of the analysis and examine in depth the flow chart reported in Section 3.1. In Chapter 4 we give the radial velocities measured with our IDL procedure for all available targets. We obtain an rms scatter in radial velocities of about 7 m/s. Finally, we conclude that GIANO can be used to measure radial velocities of late type stars with an accuracy close to or better than 10 m/s, using telluric lines as wevelength reference. In 2014 September GIANO is being operative at TNG for Science Verification and more observational data will allow to further refine this analysis.