6 resultados para shoulder joint

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nel presente lavoro sono esposti i comportamenti e le caratteristiche principali dei giunti incollati. Il metodo agli elementi finiti è stato studiato in modo da realizzare un modello accurato di un sistema fisico. L’analisi agli elementi finiti è stata utilizzata per effettuare una simulazione numerica di un single-strap joint in alluminio e in CFRP sotto un carico di trazione assiale. L’effetto di una modifica della distanza tra le lastre è stato studiato e i risultati confrontati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esposizione di comportamenti e caratteristiche principali dei giunti incollati. Il metodo agli elementi finiti è stato studiato in modo da realizzare un modello accurato di un sistema fisico. L’analisi agli elementi finiti è stata utilizzata per effettuare una simulazione numerica di un double-strap joint in alluminio e in CFRP sotto un carico di trazione assiale. L’effetto di una modifica della distanza tra le lastre è stato studiato e i risultati confrontati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present thesis was to investigate the influence of lower-limb joint models on musculoskeletal model predictions during gait. We started our analysis by using a baseline model, i.e., the state-of-the-art lower-limb model (spherical joint at the hip and hinge joints at the knee and ankle) created from MRI of a healthy subject in the Medical Technology Laboratory of the Rizzoli Orthopaedic Institute. We varied the models of knee and ankle joints, including: knee- and ankle joints with mean instantaneous axis of rotation, universal joint at the ankle, scaled-generic-derived planar knee, subject-specific planar knee model, subject-specific planar ankle model, spherical knee, spherical ankle. The joint model combinations corresponding to 10 musculoskeletal models were implemented into a typical inverse dynamics problem, including inverse kinematics, inverse dynamics, static optimization and joint reaction analysis algorithms solved using the OpenSim software to calculate joint angles, joint moments, muscle forces and activations, joint reaction forces during 5 walking trials. The predicted muscle activations were qualitatively compared to experimental EMG, to evaluate the accuracy of model predictions. Planar joint at the knee, universal joint at the ankle and spherical joints at the knee and at the ankle produced appreciable variations in model predictions during gait trials. The planar knee joint model reduced the discrepancy between the predicted activation of the Rectus Femoris and the EMG (with respect to the baseline model), and the reduced peak knee reaction force was considered more accurate. The use of the universal joint, with the introduction of the subtalar joint, worsened the muscle activation agreement with the EMG, and increased ankle and knee reaction forces were predicted. The spherical joints, in particular at the knee, worsened the muscle activation agreement with the EMG. A substantial increase of joint reaction forces at all joints was predicted despite of the good agreement in joint kinematics with those of the baseline model. The introduction of the universal joint had a negative effect on the model predictions. The cause of this discrepancy is likely to be found in the definition of the subtalar joint and thus, in the particular subject’s anthropometry, used to create the model and define the joint pose. We concluded that the implementation of complex joint models do not have marked effects on the joint reaction forces during gait. Computed results were similar in magnitude and in pattern to those reported in literature. Nonetheless, the introduction of planar joint model at the knee had positive effect upon the predictions, while the use of spherical joint at the knee and/or at the ankle is absolutely unadvisable, because it predicted unrealistic joint reaction forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il metodo agli elementi finiti è stato utilizzato per valutare la distribuzione dei carichi e delle deformazioni in numerose componenti del corpo umano. L'applicazione di questo metodo ha avuto particolare successo nelle articolazioni con geometria semplice e condizioni di carico ben definite, mentre ha avuto un impatto minore sulla conoscenza della biomeccanica delle articolazioni multi-osso come il polso. Lo scopo di questo lavoro è quello di valutare gli aspetti clinici e biomeccanici dell’articolazione distale radio-ulnare, attraverso l’utilizzo di metodi di modellazione e di analisi agli elementi finiti. Sono stati progettati due modelli 3D a partire da immagini CT, in formato DICOM. Le immagini appartenevano ad un paziente con articolazione sana e ad un paziente con articolazione patologica, in particolare si trattava di una dislocazione ulnare traumatica. Le componenti principali dei modelli presi in considerazione sono stati: radio, ulna, cartilagine, legamento interosso, palmare e distale. Per la realizzazione del radio e dell’ulna sono stati utilizzati i metodi di segmentazione “Thresholding” e “RegionGrowing” sulle immagini e grazie ad operatori morfologici, è stato possibile distinguere l’osso corticale dall’osso spongioso. Successivamente è stata creata la cartilagine presente tra le due ossa, attraverso operazioni di tipo booleano. Invece, i legamenti sono stati realizzati prendendo i punti-nodo del radio e dell’ulna e formando le superfici tra di essi. Per ciascuna di queste componenti, sono state assegnate le corrispondenti proprietà dei materiali. Per migliorare la qualità dei modelli, sono state necessarie operazioni di “Smoothing” e “Autoremesh”. In seguito, è stata eseguita un’analisi agli elementi finiti attraverso l’uso di vincoli e forze, così da simulare il comportamento delle articolazioni. In particolare, sono stati simulati lo stress e la deformazione. Infine, grazie ai risultati ottenuti dalle simulazioni, è stato possibile verificare l’eventuale rischio di frattura in differenti punti anatomici del radio e dell’ulna nell’articolazione sana e patologica.