2 resultados para sample preparation

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The full blood cell (FBC) count is the most common indicator of diseases. At present hematology analyzers are used for the blood cell characterization, but, recently, there has been interest in using techniques that take advantage of microscale devices and intrinsic properties of cells for increased automation and decreased cost. Microfluidic technologies offer solutions to handling and processing small volumes of blood (2-50 uL taken by finger prick) for point-of-care(PoC) applications. Several PoC blood analyzers are in use and may have applications in the fields of telemedicine, out patient monitoring and medical care in resource limited settings. They have the advantage to be easy to move and much cheaper than traditional analyzers, which require bulky instruments and consume large amount of reagents. The development of miniaturized point-of-care diagnostic tests may be enabled by chip-based technologies for cell separation and sorting. Many current diagnostic tests depend on fractionated blood components: plasma, red blood cells (RBCs), white blood cells (WBCs), and platelets. Specifically, white blood cell differentiation and counting provide valuable information for diagnostic purposes. For example, a low number of WBCs, called leukopenia, may be an indicator of bone marrow deficiency or failure, collagen- vascular diseases, disease of the liver or spleen. The leukocytosis, a high number of WBCs, may be due to anemia, infectious diseases, leukemia or tissue damage. In the laboratory of hybrid biodevices, at the University of Southampton,it was developed a functioning micro impedance cytometer technology for WBC differentiation and counting. It is capable to classify cells and particles on the base of their dielectric properties, in addition to their size, without the need of labeling, in a flow format similar to that of a traditional flow cytometer. It was demonstrated that the micro impedance cytometer system can detect and differentiate monocytes, neutrophils and lymphocytes, which are the three major human leukocyte populations. The simplicity and portability of the microfluidic impedance chip offer a range of potential applications in cell analysis including point-of-care diagnostic systems. The microfluidic device has been integrated into a sample preparation cartridge that semi-automatically performs erythrocyte lysis before leukocyte analysis. Generally erythrocytes are manually lysed according to a specific chemical lysis protocol, but this process has been automated in the cartridge. In this research work the chemical lysis protocol, defined in the patent US 5155044 A, was optimized in order to improve white blood cell differentiation and count performed by the integrated cartridge.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Opportunistic diseases caused by Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV) is an omnipresent global challenge. In order to manage these epidemics, we need to have low cost and easily deployable platforms at the point-of-care in high congestions regions like airports and public transit systems. In this dissertation we present our findings in using Localized Surface Plasmon Resonance (LSPR)-based detection of pathogens and other clinically relevant applications using microfluidic platforms at the point-of-care setting in resource constrained environment. The work presented here adopts the novel technique of LSPR to multiplex a lab-on-a-chip device capable of quantitatively detecting various types of intact viruses and its various subtypes, based on the principle of a change in wavelength occurring when metal nano-particle surface is modified with a specific surface chemistry allowing the binding of a desired pathogen to a specific antibody. We demonstrate the ability to detect and quantify subtype A, B, C, D, E, G and panel HIV with a specificity of down to 100 copies/mL using both whole blood sample and HIV-patient blood sample discarded from clinics. These results were compared against the gold standard Reverse Transcriptase Polymerase Chain Reaction (RT-qPCR). This microfluidic device has a total evaluation time for the assays of about 70 minutes, where 60 minutes is needed for the capture and 10 minutes for data acquisition and processing. This LOC platform eliminates the need for any sample preparation before processing. This platform is highly multiplexable as the same surface chemistry can be adapted to capture and detect several other pathogens like dengue virus, E. coli, M. Tuberculosis, etc.