2 resultados para replacement of RGPs

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The main purpose of ultrarelativistic heavy-ion collisions is the investigation of the QGP. The ALICE experiment situated at the CERN has been specifically designed to study heavy-ion collisions for centre-of-mass energies up to 5.5 per nucleon pair. Extended particle identification capability is one of the main characteristics of the ALICE experiment. In the intermediate momentum region (up to 2.5 GeV/c for pi/K and 4 GeV/c for K/p), charged particles are identified in the ALICE experiment by the Time of Flight (TOF) detector. The ALICE-TOF system is a large-area detector based on the use of Multi-gap Resistive Plate Chamber (MRPC) built with high efficiency, fast response and intrinsic time resolution better than 40 ps. This thesis work, developed with the ALICE-TOF Bologna group, is part of the efforts carried out to adapt the read-out of the detector to the new requirements after the LHC Long Shutdown 2. Tests on the feasibility of a new read-out scheme for the TOF detector have been performed. In fact, the achievement of a continuous read-out also for the TOF detector would not be affordable if one considers the replacement of the TRM cards both for hardware and budget reasons. Actually, the read-out of the TOF is limited at 250 kHz i.e. it would be able to collect up to just a fourth of the maximum collision rate potentially achievable for pp interactions. In this Master’s degree thesis work, I discuss a different read-out system for the ALICE-TOF detector that allows to register all the hits at the interaction rate of 1 MHz foreseen for pp interactions after the 2020, by using the electronics currently available. Such solution would allow the ALICE-TOF detector to collect all the hits generated by pp collisions at 1 MHz interaction rate, which corresponds to an amount four times larger than that initially expected at such frequencies with the triggered read-out system operated at 250 kHz for LHC Run 3. The obtained results confirm that the proposed read-out scheme is a viable option for the ALICE TOF detector. The results also highlighted that it will be advantageous if the ALICE-TOF group also implement an online monitoring system of noisy channels to allow their deactivation in real time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.