4 resultados para premature rupture of membranes

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone is continually being removed and replaced through the actions of basic multicellular units (BMU). This constant upkeep is necessary to remove microdamage formed naturally due to fatigue and thus maintain the integrity of the bone. The repair process in bone is targeted, meaning that a BMU travels directly to the site of damage and repairs it. It is still unclear how targeted remodelling is stimulated and directed but it is highly likely that osteocytes play a role. A number of theories have been advanced to explain the microcrack osteocyte interaction but no complete mechanism has been demonstrated. Osteocytes are connected to each other by dendritic processes. The “scissors model" proposed that the rupture of these processes where they cross microcracks signals the degree of damage and the urgency of the necessary repair. In its original form it was proposed that under applied compressive loading, microcrack faces will be pressed together and undergo relative shear movement. If this movement is greater than the width of an osteocyte process, then the process will be cut in a “scissors like" motion, releasing RANKL, a cytokine known to be essential in the formation of osteoclasts from pre-osteoclasts. The main aim of this thesis was to investigate this theoretical model with a specific focus on microscopy and finite element modelling. Previous studies had proved that cyclic stress was necessary for osteocyte process rupture to occur. This was a divergence from the original “scissors model" which had proposed that the cutting of cell material occurred in one single action. The present thesis is the first study to show fatigue failure in cellular processes spanning naturally occurring cracks and it's the first study to estimate the cyclic strain range and relate it to the number of cycles to failure, for any type of cell. Rupture due to shear movement was ruled out as microcrack closing never occurred, as a result of plastic deformation of the bone. Fatigue failure was found to occur due to cyclic tensile stress in the locality of the damage. The strain range necessary for osteocyte process rupture was quantified. It was found that the lower the process strain range the greater the number of cycles to cell process failure. FEM modelling allowed to predict stress in the vicinity of an osteocyte process and to analyse its interaction with the bone surrounding it: simulations revealed evident creep effects in bone during cyclic loading. This thesis confirms and dismisses aspects of the “scissors model". The observations support the model as a viable mechanism of microcrack detection by the osteocyte network, albeit in a slightly modified form where cyclic loading is necessary and the method of rupture is fatigue failure due to cyclic tensile motion. An in depth study was performed focusing on microscopy analysis of naturally occurring cracks in bone and FEM simulation analysis of an osteocyte process spanning a microcrack in bone under cyclic load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The BLEVE, acronym for Boiling Liquid Expanding Vapour Explosion, is one of the most dangerous accidents that can occur in pressure vessels. It can be defined as an explosion resulting from the failure of a vessel containing a pressure liquefied gas stored at a temperature significantly above its boiling point at atmospheric pressure. This phenomenon frequently appears when a vessel is engulfed by a fire: the heat causes the internal pressure to raise and the mechanical proprieties of the wall to decrease, with the consequent rupture of the tank and the instantaneous release of its whole content. After the breakage, the vapour outflows and expands and the liquid phase starts boiling due to the pressure drop. The formation and propagation of a distructive schock wave may occur, together with the ejection of fragments, the generation of a fireball if the stored fluid is flammable and immediately ignited or the atmospheric dispersion of a toxic cloud if the fluid contained inside the vessel is toxic. Despite the presence of many studies on the BLEVE mechanism, the exact causes and conditions of its occurrence are still elusive. In order to better understand this phenomenon, in the present study first of all the concept and definition of BLEVE are investigated. A historical analysis of the major events that have occurred over the past 60 years is described. A research of the principal causes of this event, including the analysis of the substances most frequently involved, is presented too. Afterwards a description of the main effects of BLEVEs is reported, focusing especially on the overpressure. Though the major aim of the present thesis is to contribute, with a comparative analysis, to the validation of the main models present in the literature for the calculation and prediction of the overpressure caused by BLEVEs. In line with this purpose, after a short overview of the available approaches, their ability to reproduce the trend of the overpressure is investigated. The overpressure calculated with the different models is compared with values deriving from events happened in the past and ad-hoc experiments, focusing the attention especially on medium and large scale phenomena. The ability of the models to consider different filling levels of the reservoir and different substances is analyzed too. The results of these calculations are extensively discussed. Finally some conclusive remarks are reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questa tesi si è voluta porre l’attenzione sulla suscettibilità alle alte temperature delle resine che li compongono. Lo studio del comportamento alle alte temperature delle resine utilizzate per l’applicazione dei materiali compositi è risultato un campo di studio ancora non completamente sviluppato, nel quale c’è ancora necessità di ricerche per meglio chiarire alcuni aspetti del comportamento. L’analisi di questi materiali si sviluppa partendo dal contesto storico, e procedendo successivamente ad una accurata classificazione delle varie tipologie di materiali compositi soffermandosi sull’ utilizzo nel campo civile degli FRP (Fiber Reinforced Polymer) e mettendone in risalto le proprietà meccaniche. Considerata l’influenza che il comportamento delle resine riveste nel comportamento alle alte temperature dei materiali compositi si è, per questi elementi, eseguita una classificazione in base alle loro proprietà fisico-chimiche e ne sono state esaminate le principali proprietà meccaniche e termiche quali il modulo elastico, la tensione di rottura, la temperatura di transizione vetrosa e il fenomeno del creep. Sono state successivamente eseguite delle prove sperimentali, effettuate presso il Laboratorio Resistenza Materiali e presso il Laboratorio del Dipartimento di Chimica Applicata e Scienza dei Materiali, su dei provini confezionati con otto differenti resine epossidiche. Per valutarne il comportamento alle alte temperature, le indagini sperimentali hanno valutato dapprima le temperature di transizione vetrosa delle resine in questione e, in seguito, le loro caratteristiche meccaniche. Dalla correlazione dei dati rilevati si sono cercati possibili legami tra le caratteristiche meccaniche e le proprietà termiche delle resine. Si sono infine valutati gli aspetti dell’applicazione degli FRP che possano influire sul comportamento del materiale composito soggetto alle alte temperature valutando delle possibili precauzioni che possano essere considerate in fase progettuale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.