4 resultados para overland-flow field

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A way to investigate turbulence is through experiments where hot wire measurements are performed. Analysis of the in turbulence of a temperature gradient on hot wire measurements is the aim of this thesis work. Actually - to author's knowledge - this investigation is the first attempt to document, understand and ultimately correct the effect of temperature gradients on turbulence statistics. However a numerical approach is used since instantaneous temperature and streamwise velocity fields are required to evaluate this effect. A channel flow simulation at Re_tau = 180 is analyzed to make a first evaluation of the amount of error introduced by temperature gradient inside the domain. Hot wire data field is obtained processing the numerical flow field through the application of a proper version of the King's law, which connect voltage, velocity and temperature. A drift in mean streamwise velocity profile and rms is observed when temperature correction is performed by means of centerline temperature. A correct mean velocity pro�le is achieved correcting temperature through its mean value at each wall normal position, but a not negligible error is still present into rms. The key point to correct properly the sensed velocity from the hot wire is the knowledge of the instantaneous temperature field. For this purpose three correction methods are proposed. At the end a numerical simulation at Re_tau =590 is also evaluated in order to confirm the results discussed earlier.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Questo lavoro si concentra sullo studio fluidodinamico del flusso multifase cavitante di un iniettore per applicazioni a motori ad iniezione diretta (GDI). L’analisi è stata svolta tramite l’uso del software CFD (Computational Fluid Dynamics) Star-CCM+^® sviluppato da CD-ADAPCO. L’obiettivo di questo studio è investigare i motivi che portano ad un diverso comportamento tra i rilievi della prova sperimentale di caratterizzazione dell’iniettore e quanto atteso dai valori nominali dettati dalla specifica dell’iniettore, con particolare riferimento alla distribuzione di portata fra i diversi ugelli. Il presente lavoro fa parte di una coppia di elaborati collegati tra loro e, pertanto, ha inoltre lo scopo di fornire dati utili allo sviluppo dell’altro tema di analisi mirato alla individuazione di parametri di qualità della miscela aria-combustibile non reagente utili alla previsione della formazione del particolato prodotto dalla combustione di un motore GDI. L’elaborato, costituito di 5 capitoli, è strutturato secondo lo schema sottostante. Nel capitolo 1 vengono presentate le motivazioni che lo hanno avviato e viene esposto lo stato dell’arte della tecnologia GDI. Il capitolo 2 è a sfondo teorico: in esso vengono riportati i fondamenti del processo di cavitazione nella prima parte e i modelli numerici utilizzati nell’analisi nella seconda. Il capitolo 3 descrive la modellazione e successiva validazione dei modelli tramite confronto con il test case ‘Comprensive hydraulic and flow field documentation in model throttle experiments under cavitation conditions’ (E. Winklhofer, 2001). Nella scelta dei modelli e dei parametri relativi, l’analisi si è basata su precedenti lavori trovati in letteratura. Successivamente è stato svolto uno studio di sensibilità per valutare la stabilità della soluzione a piccole variazioni nei valori dei parametri. La scelta dei parametri modellistici nel caso di interesse, l’iniettore multihole, si è basata inizialmente sui valori ‘ottimali’ ottenuti nel test case ed è l’argomento del capitolo 4. All’interno del capitolo si parla inoltre dell’analisi di sensibilità successiva, svolta con lo scopo di comprendere i motivi che portano allo sbilanciamento tra fori corrispondenti e al maggiore sviluppo del getto centrale rispetto agli altri. Nel capitolo 5 dopo un breve riepilogo dei punti fondamentali trattati nello svolgimento dell’elaborato, si tirano le conclusioni sull’analisi e si espongono gli sviluppi futuri.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Numerous types of acute respiratory failure are routinely treated using non-invasive ventilatory support (NIV). Its efficacy is well documented: NIV lowers intubation and death rates in various respiratory disorders. It can be delivered by means of face masks or head helmets. Currently the scientific community’s interest about NIV helmets is mostly focused on optimising the mixing between CO2 and clean air and on improving patient comfort. To this end, fluid dynamic analysis plays a particularly important role and a two- pronged approach is frequently employed. While on one hand numerical simulations provide information about the entire flow field and different geometries, they exhibit require huge temporal and computational resources. Experiments on the other hand help to validate simulations and provide results with a much smaller time investment and thus remain at the core of research in fluid dynamics. The aim of this thesis work was to develop a flow bench and to utilise it for the analysis of NIV helmets. A flow test bench and an instrumented mannequin were successfully designed, produced and put into use. Experiments were performed to characterise the helmet interface in terms of pressure drop and flow rate drop over different inlet flow rates and outlet pressure set points. Velocity measurements by means of Particle Image Velocimetry were performed. Pressure drop and flow rate characteristics from experiments were contrasted with CFD data and sufficient agreement was observed between both numerical and experimental results. PIV studies permitted qualitative and quantitative comparisons with numerical simulation data and offered a clear picture of the internal flow behaviour, aiding the identification of coherent flow features.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mixing is a fundamental unit operation in the pharmaceutical industry to ensure consistent product quality across different batches. It is usually carried out in mechanically stirred tanks, with a large variety of designs according to the process requirements. A key aspect of pharmaceutical manufacturing is the extensive and meticulous cleaning of the vessels between runs to prevent the risk of contamination. Single-use reactors represent an increasing trend in the industry since they do not require cleaning and sterilization, reducing the need for utilities such as steam to sterilize equipment and the time between production batches. In contrast to traditional stainless steel vessels, single-use reactors consist of a plastic bag used as a vessel and disposed of after use. This thesis aims to characterize the fluid dynamics features and the mixing performance of a commercially available single-use reactor. The characterization employs a combination of various experimental techniques. The analysis starts with the visual observation of the liquid behavior inside the vessel, focusing on the vortex shape evolution at different impeller speeds. The power consumption is then measured using a torque meter to quantify the power number. Particle Image Velocimetry (PIV) is employed to investigate local fluid dynamics properties such as mean flow field and mean and rms velocity profiles. The same experimental setup of PIV is exploited for another optical measurement technique, the Planar Laser-Induced Fluorescence (PLIF). The PLIF measurements complete the characterization of the reactor with the qualitative visualization of the turbulent flow and the quantitative assessment of the system performance through the mixing time. The results confirm good mixing performances for the single-use reactor over the investigated impeller speeds and reveal that the filling volume plays a significant role in the fluid dynamics of the system.