7 resultados para novel view

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim of the present work of thesis is to synthesize new non-noble metal based complexes to be employ in redox reactions by a metal-ligand cooperative mechanism. The need of replacing toxic and expensive precious metal complexes with more available and benign metals, has led to the development of new compounds based on cobalt and iron, which are the metals investigated in this study. A carbonyl-tetrahydroborato-bis[(2-diisopropylphosphino)ethyl]amine-cobalt complex bearing a PNP-type ligand is synthesized by a three-step route. Optimization attempt of reaction route were assessed in order to lowering reaction times and solvent waste. New cobalt complex has been tested in esters hydrogenation as well as in acceptorless dehydrogenative coupling of ethanol. Other varieties of substrates were also tested in order to evaluate any possible applications. Concerning iron complex, dicarbonyl-(η4-3,4-bis(4-methoxyphenyl)-2,5-diphenylcyclopenta-2,4-dienone)(1,3-dimethyl-ilidene)iron is synthesized by a three steps route, involving transmetallation of a silver complex, derived from an imidazolium salt, to iron complex. In order to avoid solvent waste, optimization is assessed. Studies were performed to assess activity of triscarbonyl iron precursor toward imidazolium salt and silver complexes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study investigates the feasibility of a new application able to check the heart failure status in a patient through the estimation of the venous distension. In this way it would be possible to follow up patients, avoiding invasive or expensive exams such as cardiac catheterization and echocardiography. Moreover, the devices would also be able to diagnose the decline of the disease, in order to allow a new adaptation to therapy, and vice versa to check the improvement in the patient’s conditions after the CRT device implant. This thesis is essentially divided into three parts: an analytical model was used to obtain an estimation of the error committed for the calculation of the CSA and to understand how the accuracy and sensitivity depend on the different configurations of the electrodes and the catheter position inside the vein; secondly, an in-vitro experiment was carried out in order to verify the practical feasibility for these kinds of measurements, in a very simplified model; in the end, several animal experiments were done to test the in-vivo practicability of the proposed method. The obtained results showed the feasibility of this approach. In fact, the error committed in the estimation of CSA, during the animal experiments, can be considered acceptable (CSAerror_max ≈ -14%). Moreover, it has been demonstrated that the conductance catheter allows assessing, not only the vein CSA, but also the breathing of the animal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La scoperta dei semiconduttori amorfi ha segnato l’era della microelettronica su larga scala rendendo possibile il loro impiego nelle celle solari o nei display a matrice attiva. Infatti, mentre i semiconduttori a cristalli singoli non sono consoni a questo tipo di applicazioni e i s. policristallini presentano il problema dei bordi di grano, i film amorfi possono essere creati su larga scala (>1 m^2) a basse temperature (ad es. <400 °C) ottenendo performance soddisfacenti sia su substrati rigidi che flessibili. Di recente la ricerca sta compiendo un grande sforzo per estendere l’utilizzo di questa nuova elettronica flessibile e su larga scala ad ambienti soggetti a radiazioni ionizzanti, come lo sono i detector di radiazioni o l’elettronica usata in applicazioni spaziali (satelliti). A questa ricerca volge anche la mia tesi, che si confronta con la fabbricazione e la caratterizzazione di transistor a film sottili basati su ossidi semiconduttori ad alta mobilità e lo studio della loro resistenza ai raggi X. La micro-fabbricazione, ottimizzazione e caratterizzazione dei dispositivi è stata realizzata nei laboratori CENIMAT e CEMOP dell’Università Nova di Lisbona durante quattro mesi di permanenza. Tutti i dispositivi sono stati creati con un canale n di ossido di Indio-Gallio-Zinco (IGZO). Durante questo periodo è stato realizzato un dispositivo dalle ottime performance e con interessanti caratteristiche, una delle quali è la non variazione del comportamento capacitivo in funzione della frequenza e la formidabile resistenza alle radiazioni. Questo dispositivo presenta 114 nm di dielettrico, realizzato con sette strati alternati di SiO2/ Ta2O5. L’attività di ricerca svolta al Dipartimento di Fisica e Astronomia di Bologna riguarda prevalentemente lo studio degli effetti delle radiazioni ionizzanti su TFTs. Gli esperimenti hanno rivelato che i dispositivi godono di una buona stabilità anche se soggetti alle radiazioni. Infatti hanno mostrato performance pressoché inalterate anche dopo un’esposizione a 1 kGy di dose cumulativa di raggi X mantenendo circa costanti parametri fondamentali come la mobilità, il threshold voltage e la sub-threshold slope. Inoltre gli effetti dei raggi X sui dispositivi, così come parametri fondamentali quali la mobilità, si sono rivelati essere notevolmente influenzati dallo spessore del dielettrico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional inorganic materials for x-ray radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, me- chanical sti ffness, lack of tissue-equivalence and toxicity. Semiconducting organic polymers represent an alternative and have been employed as di- rect photoconversion material in organic diodes. In contrast to inorganic detector materials, polymers allow low-cost and large area fabrication by sol- vent based methods. In addition their processing is compliant with fexible low-temperature substrates. Flexible and large-area detectors are needed for dosimetry in medical radiotherapy and security applications. The objective of my thesis is to achieve optimized organic polymer diodes for fexible, di- rect x-ray detectors. To this end polymer diodes based on two different semi- conducting polymers, polyvinylcarbazole (PVK) and poly(9,9-dioctyluorene) (PFO) have been fabricated. The diodes show state-of-the-art rectifying be- haviour and hole transport mobilities comparable to reference materials. In order to improve the X-ray stopping power, high-Z nanoparticle Bi2O3 or WO3 where added to realize a polymer-nanoparticle composite with opti- mized properities. X-ray detector characterization resulted in sensitivties of up to 14 uC/Gy/cm2 for PVK when diodes were operated in reverse. Addition of nanoparticles could further improve the performance and a maximum sensitivy of 19 uC/Gy/cm2 was obtained for the PFO diodes. Compared to the pure PFO diode this corresponds to a five-fold increase and thus highlights the potentiality of nanoparticles for polymer detector design. In- terestingly the pure polymer diodes showed an order of magnitude increase in sensitivity when operated in forward regime. The increase was attributed to a different detection mechanism based on the modulation of the diodes conductivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Con riferimento alla realizzazione di tunnel per servizi interrati, l’incertezza che contraddistingue il quadro geologico, oltre che incidere sui costi, riveste un ruolo chiave nella progettazione preliminare. Sebbene un’approfondita caratterizzazione geotecnica e geologica del volume di terreno inerente l’opera di scavo sia generalmente parte integrante del progetto, non è comunque possibile eliminare del tutto tali incertezze per via dell’estensione del volume interessato oltre che per la disomogeneità che sempre contraddistingue il terreno. Generalmente, investigazioni in corso d’opera e interventi di stabilizzazione devono essere previsti per contenere i costi di perforazione ed ottimizzare la progettazione. Ad esempio, tra i metodi di esplorazione geotecnica figurano i tunnel pilota, i quali sono in grado di garantire un’ottimale caratterizzazione del quadro geotecnico del sottosuolo. Con riferimento agli interventi di stabilizzazione del terreno, adottabili laddove una perforazione tradizionale non consentirebbe il tunnelling, vi è un vasta gamma di scelta. Pertanto, da una prima analisi delle problematiche connesse al tunnelling emerge che la stabilizzazione delle facce di scavo riveste un’importanza e un risconto applicativo di prim’ordine. Questa tesi si inserisce all’interno di un progetto che promuove un’innovativa ed economica tecnica di stabilizzazione dei tunnel per suzione tenendo quindi conto dell’influenza della suzione sulla coesione non drenata.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is based on the study of new synthetic paths to obtain thioimidate N-oxides (TINOs) from D-ribose and to study their reactivity with the purpose to obtain ketonitrones. TINOs, aren’t well known molecules, but these enantiomerically pure backbones could be valuable intermediates in the synthesis of novel ketonitrones which are key intermediates in the synthesis of iminosugars. TINOs were discovered from the study of glucoraphanin, a particular glucosinolate, that unexpectedly cyclized into a TINO after desulfatation, by a spontaneous intramolecular Michael addition. The first part of this work was to synthetize the TINO 3 from D-ribose 1. The key step was the desilylative cyclisation of a suitably functionalized thiohydroximate 2. Based on precedent work developed in the laboratory, we could obtain the thiohydroximate from D-ribose. We then focused our studies on the cyclisation step trying to find the suitable substituents that could give the TINO in good yield by desilylative cyclisation. The second part of the project is to obtain ketonitrones 4 by palladiumcatalyzed coupling reaction.