Antarctic cloud spectral emission from ground-based measurements, a focus on far infrared signatures
Resumo:
The present work belongs to the PRANA project, the first extensive field campaign of observation of atmospheric emission spectra covering the Far InfraRed spectral region, for more than two years. The principal deployed instrument is REFIR-PAD, a Fourier transform spectrometer used by us to study Antarctic cloud properties. A dataset covering the whole 2013 has been analyzed and, firstly, a selection of good quality spectra is performed, using, as thresholds, radiance values in few chosen spectral regions. These spectra are described in a synthetic way averaging radiances in selected intervals, converting them into BTs and finally considering the differences between each pair of them. A supervised feature selection algorithm is implemented with the purpose to select the features really informative about the presence, the phase and the type of cloud. Hence, training and test sets are collected, by means of Lidar quick-looks. The supervised classification step of the overall monthly datasets is performed using a SVM. On the base of this classification and with the help of Lidar observations, 29 non-precipitating ice cloud case studies are selected. A single spectrum, or at most an average over two or three spectra, is processed by means of the retrieval algorithm RT-RET, exploiting some main IR window channels, in order to extract cloud properties. Retrieved effective radii and optical depths are analyzed, to compare them with literature studies and to evaluate possible seasonal trends. Finally, retrieval output atmospheric profiles are used as inputs for simulations, assuming two different crystal habits, with the aim to examine our ability to reproduce radiances in the FIR. Substantial mis-estimations are found for FIR micro-windows: a high variability is observed in the spectral pattern of simulation deviations from measured spectra and an effort to link these deviations to cloud parameters has been performed.
Resumo:
Negli anni recenti, lo sviluppo dell’elettronica organica ha condotto all’impiego di materiali organici alla base di numerosi dispositivi elettronici, quali i diodi ad emissione di luce, i transistor ad effetto di campo, le celle solari e i rivelatori di radiazione. Riguardo quest’ultimi, gli studi riportati in letteratura si riferiscono per la maggiore a dispositivi basati su materiali organici a film sottile, che tuttavia presentano problemi relativi ad instabilità e degradazione. Come verrà illustrato, l’impiego di singoli cristalli organici come materiali alla base di questi dispositivi permette il superamento delle principali limitazioni che caratterizzano i rivelatori basati su film sottili. In questa attività sperimentale, dispositivi basati su cristalli organici semiconduttori verranno caratterizzati in base alle principali figure di merito dei rivelatori. Tra i campioni testati, alcuni dispositivi basati su singoli cristalli di 6,13-bis (triisopropylsilylethynyl)-pentacene (TIPS-Pentacene) e 5,6,11,12-tetraphenyltetracene (Rubrene) hanno mostrato interessanti proprietà e sono stati quindi maggiormente studiati.
Resumo:
Conventional inorganic materials for x-ray radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, me- chanical sti ffness, lack of tissue-equivalence and toxicity. Semiconducting organic polymers represent an alternative and have been employed as di- rect photoconversion material in organic diodes. In contrast to inorganic detector materials, polymers allow low-cost and large area fabrication by sol- vent based methods. In addition their processing is compliant with fexible low-temperature substrates. Flexible and large-area detectors are needed for dosimetry in medical radiotherapy and security applications. The objective of my thesis is to achieve optimized organic polymer diodes for fexible, di- rect x-ray detectors. To this end polymer diodes based on two different semi- conducting polymers, polyvinylcarbazole (PVK) and poly(9,9-dioctyluorene) (PFO) have been fabricated. The diodes show state-of-the-art rectifying be- haviour and hole transport mobilities comparable to reference materials. In order to improve the X-ray stopping power, high-Z nanoparticle Bi2O3 or WO3 where added to realize a polymer-nanoparticle composite with opti- mized properities. X-ray detector characterization resulted in sensitivties of up to 14 uC/Gy/cm2 for PVK when diodes were operated in reverse. Addition of nanoparticles could further improve the performance and a maximum sensitivy of 19 uC/Gy/cm2 was obtained for the PFO diodes. Compared to the pure PFO diode this corresponds to a five-fold increase and thus highlights the potentiality of nanoparticles for polymer detector design. In- terestingly the pure polymer diodes showed an order of magnitude increase in sensitivity when operated in forward regime. The increase was attributed to a different detection mechanism based on the modulation of the diodes conductivity.
Resumo:
The aim of this Thesis work is to study the multi-frequency properties of the Ultra Luminous Infrared Galaxy (ULIRG) IRAS 00183-7111 (I00183) at z = 0.327, connecting ALMA sub-mm/mm observations with those at high energies in order to place constraints on the properties of its central power source and verify whether the gas traced by the CO may be responsible for the obscuration observed in X-rays. I00183 was selected from the so-called Spoon diagnostic diagram (Spoon et al. 2007) for mid-infrared spectra of infrared galaxies based on the equivalent width of the 6.2 μm Polycyclic Aromatic Hydrocarbon (PAH) emission feature versus the 9.7 μm silicate strength. Such features are a powerful tool to investigate the contribution of star formation and AGN activity in this class of objects. I00183 was selected from the top-left region of the plot where the most obscured sources, characterized by a strong Si absorption feature, are located. To link the sub-mm/mm to the X-ray properties of I00183, ALMA archival Cycle 0 data in Band 3 (87 GHz) and Band 6 (270 GHz) have been calibrated and analyzed, using CASA software. ALMA Cycle 0 was the Early Science program for which data reprocessing is strongly suggested. The main work of this Thesis consisted in reprocessing raw data to provide an improvement with respect to the available archival products and results, which were obtained using standard procedures. The high-energy data consists of Chandra, XMM-Newton and NuSTAR observations which provide a broad coverage of the spectrum in the energy range 0.5 − 30 keV. Chandra and XMM archival data were used, with an exposure time of 22 and 22.2 ks, respectively; their reduction was carried out using CIAO and SAS software. The 100 ks NuSTAR are still private and the spectra were obtained by courtesy of the PI (K. Iwasawa). A detailed spectral analysis was done using XSPEC software; the spectral shape was reproduced starting from simple phenomenological models, and then more physical models were introduced to account for the complex mechanisms that involve this source. In Chapter 1, an overview of the scientific background is discussed, with a focus on the target, I00183, and the Spoon diagnostic diagram, from which it was originally selected. In Chapter 2, the basic principles of interferometry are briefly introduced, with a description of the calibration theory applied to interferometric observations. In Chapter 3, ALMA and its capabilities, both current and future, are shown, explaining also the complex structure of the ALMA archive. In Chapter 4, the calibration of ALMA data is presented and discussed, showing also the obtained imaging products. In Chapter 5, the analysis and discussion of the main results obtained from ALMA data is presented. In Chapter 6, the X-ray observations, data reduction and spectral analysis are reported, with a brief introduction to the basic principle of X-ray astronomy and the instruments from which the observations were carried out. Finally, the overall work is summarized, with particular emphasis on the main obtained results and the possible future perspectives.
Resumo:
Cosmic X-ray background synthesis models (Gilli 2007) require a significant fraction of obscured AGN, some of which are expected to be heavily obscured (Compton-thick), but the number density of observationally found obscured sources is still an open issue (Vignali 2010, 2014). This thesis work takes advantage of recent NuSTAR data and is based on a multiwavelength research approach. Gruppioni et al. 2016 compared the AGN bolometric luminosity, for a sample of local 12 micron Seyfert galaxies, derived from the SED decomposition to the same quantity obtained by the 2-10 keV luminosity (IPAC-NED). A difference up to two orders of magnitude resulted between these quantities for some sources. Thus, the intrinsic X-ray luminosity obtained correcting for the obscuration may be underestimated. In this thesis we have tested this hypothesis by re-analysing the X-ray spectra of three of the sources (UGC05101, NGC1194 and NGC3079), for which observations from NuSTAR and Chandra and/or XMM-Newton were available. This is meant to extend our analysis to energies above 10 keV and thus estimate the AGN column density as reliable as possible. For spectral fitting we made use of both the commonly used XSPEC package and the two very recent MYtorus and BNtorus physical models. The available wide bandpass allowed us to achieve new and more solid insights into the X-ray spectral properties of these sources. The measured absorption column densities are highly suggestive of heavy obscuration. Once corrected the X-ray AGN luminosity for the obscuration estimated through our spectral analysis, we compared the L(X) values in the 2-10 keV band with those derived from the MIR band, by means of the relation by Gandhi, 2009. As expected, the values derived from this relation are in good agreement with those we measured, indicating that the column densities were underestimated in the previous literature works.
Resumo:
Cyanoacetylene HC3N is a molecule of great astronomical importance and it has been observed in many interstellar environments. Its deuterated form DC3N has been detected in number of sources from external galaxies to Galactic interstellar clouds, star-forming regions and planetary atmospheres. All these detections relied on previous laboratory investigations, which however still lack some essential information concerning its infrared spectrum. In this project, high-resolution ro-vibrational spectra of DC3N have been recorded in two energy regions: 150 – 450 cm-1 and 1800 – 2800 cm-1. In the first window the ν7← GS, 2ν7 ← ν7, ν5 ← ν7, ν5+ν7 ← 2ν7, ν6+ν7 → 2v7, 4ν7 ← 2ν7 bands have been assigned, while in the second region the three stretching fundamental bands ν1, ν2, ν3 have been observed and analysed. The 150 – 450 cm-1 region spectra have been recorded at the AILES beamline at the SOLEIL synchrotron (France), the 1800 – 2800 cm-1 spectra at the Department of Industrial Chemistry “Toso Montanari” in Bologna. In total, 2299 transitions have been assigned. Such experimental transition, together with data previously recorded for DC3N, were included in a least-squares fitting procedure from which several spectroscopic parameters have been determined with high precision and accuracy. They include rotational, vibrational and resonance constants. The spectroscopic data of DC3N have been included in a line catalog for this molecule in order to assist future astronomical observations and data interpretation. A paper which includes this research work has been published (M. Melosso, L. Bizzocchi, A. Adamczyk, E. Cane, P. Caselli, L. Colzid, L. Dorea, B. M. Giulianob, J.-C. Guillemine, M-A. Martin-Drumel, O. Piralif, A. Pietropolli Charmet , D. Prudenzano, V. M. Rivillad, F. Tamassia, Extensive ro-vibrational analysis of deuterated-cyanoacetylene (DC3N) from millimeter wavelengths to the infrared domain, Jour. of Quant. Spectr. and Rad. Tran. 254, 107221, 2020).
Resumo:
From 2010, the Proton Radius has become one of the most interest value to determine. The first proof of not complete understanding of its internal structure was the measurement of the Lamb Shift using the muonic hydrogen, leading to a value 7σ lower. A new road so was open and the Proton Radius Puzzle epoch begun. FAMU Experiment is a project that tries to give an answer to this Puzzle implementing high precision experimental apparatus. The work of this thesis is based on the study, construction and first characterization of a new detection system. Thanks to the previous experiments and simulations, this apparatus is composed by 17 detectors positioned on a semicircular crown with the related electronic circuit. The detectors' characterization is based on the use of a LabView program controlling a digital potentiometer and on other two analog potentiometers, all three used to set the amplitude of each detector to a predefined value, around 1.2 V, set on the oscilloscope by which is possible to observe the signal. This is the requirement in order to have, in the final measurement, a single high peak given by the sum of all the signals coming from the detectors. Each signal has been acquired for almost half of an hour, but the entire circuit has been maintained active for more time to observe its capacity to work for longer periods. The principal results of this thesis are given by the spectra of 12 detectors and the corresponding values of Voltages, FWHM and Resolution. The outcomes of the acquisitions show also another expected behavior: the strong dependence of the detectors from the temperature, demonstrating that an its change causes fluctuations in the signal. In turn, these fluctuations will affect the spectrum, resulting in a shifting of the curve and a lower Resolution. On the other hand, a measurement performed in stable conditions will lead to accordance between the nominal and experimental measurements, as for the detectors 10, 11 and 12 of our system.
Resumo:
The corpuscular model describes black holes as leaky bound states of gravitons. To account for the role of matter, a coherent state is built and a semiclassical description is given to the gravitational field by connecting the classical source with the quantum state for gravitons. The properties of this state can be analysed with the help of an Unruh-DeWitt detector, coupled to the quantum state of the system. The presence of a detector in general regularises the usual diverging behaviour of the field in the deep ultraviolet region, and will allow us to probe the coherent state structure and the graviton emission. In particular, a Newtonian analogue of the Unruh effect will be discussed and the coherent state will be modified to properly account for the spherical symmetry of the potential at the level of the quantum state. This correction will ensure that vacuum contributions responsible for the Unruh thermal spectrum are present in a coherent state emission process.
Resumo:
The incompatibility between the proton radius values measured in recent years has given rise to what is now called the proton radius puzzle. This discrepancy is nowadays without explanation. In order to find a solution to the proton radius puzzle a new experiment has been proposed. The aim of this experiment, called FAMU, is to obtain a new and more precise measure of the Zemach radius of the proton, ie the quantity that has the highest uncertainty in high precision spectroscopy. If this measurement confirmed the results obtained before 2010, the starting date of the puzzle, then the discrepancy would be caused by procedural errors or ignored corrections. Otherwise, the new value would indicate the presence of new physics still unkown.