7 resultados para incompleteness and inconsistency detection
em AMS Tesi di Laurea - Alm@DL - Università di Bologna
Resumo:
During the last semester of the Master’s Degree in Artificial Intelligence, I carried out my internship working for TXT e-Solution on the ADMITTED project. This paper describes the work done in those months. The thesis will be divided into two parts representing the two different tasks I was assigned during the course of my experience. The First part will be about the introduction of the project and the work done on the admittedly library, maintaining the code base and writing the test suits. The work carried out is more connected to the Software engineer role, developing features, fixing bugs and testing. The second part will describe the experiments done on the Anomaly detection task using a Deep Learning technique called Autoencoder, this task is on the other hand more connected to the data science role. The two tasks were not done simultaneously but were dealt with one after the other, which is why I preferred to divide them into two separate parts of this paper.
Measurement of CP asymmetries in $\lambda^0_b \to pk^-$ and $\lambda^0_b \to p \pi^-$ decays at LHCb
Resumo:
The LHCb experiment has been designed to perform precision measurements in the flavour physics sector at the Large Hadron Collider (LHC) located at CERN. After the recent observation of CP violation in the decay of the Bs0 meson to a charged pion-kaon pair at LHCb, it is interesting to see whether the same quark-level transition in Λ0b baryon decays gives rise to large CP-violating effects. Such decay processes involve both tree and penguin Feynman diagrams and could be sensitive probes for physics beyond the Standard Model. The measurement of the CP-violating observable defined as ∆ACP = ACP(Λ0b → pK−)−ACP(Λ0b →pπ−),where ACP(Λ0b →pK−) and ACP(Λ0b →pπ−) are the direct CP asymmetries in Λ0b → pK− and Λ0b → pπ− decays, is presented for the first time using LHCb data. The procedure followed to optimize the event selection, to calibrate particle identification, to parametrise the various components of the invariant mass spectra, and to compute corrections due to the production asymmetry of the initial state and the detection asymmetries of the final states, is discussed in detail. Using the full 2011 and 2012 data sets of pp collisions collected with the LHCb detector, corresponding to an integrated luminosity of about 3 fb−1, the value ∆ACP = (0.8 ± 2.1 ± 0.2)% is obtained. The first uncertainty is statistical and the second corresponds to one of the dominant systematic effects. As the result is compatible with zero, no evidence of CP violation is found. This is the most precise measurement of CP violation in the decays of baryons containing the b quark to date. Once the analysis will be completed with an exhaustive study of systematic uncertainties, the results will be published by the LHCb Collaboration.
Resumo:
In cardiovascular disease the definition and the detection of the ECG parameters related to repolarization dynamics in post MI patients is still a crucial unmet need. In addition, the use of a 3D sensor in the implantable medical devices would be a crucial mean in the assessment or prediction of Heart Failure status, but the inclusion of such feature is limited by hardware and firmware constraints. The aim of this thesis is the definition of a reliable surrogate of the 500 Hz ECG signal to reach the aforementioned objective. To evaluate the worsening of reliability due to sampling frequency reduction on delineation performance, the signals have been consecutively down sampled by a factor 2, 4, 8 thus obtaining the ECG signals sampled at 250, 125 and 62.5 Hz, respectively. The final goal is the feasibility assessment of the detection of the fiducial points in order to translate those parameters into meaningful clinical parameter for Heart Failure prediction, such as T waves intervals heterogeneity and variability of areas under T waves. An experimental setting for data collection on healthy volunteers has been set up at the Bakken Research Center in Maastricht. A 16 – channel ambulatory system, provided by TMSI, has recorded the standard 12 – Leads ECG, two 3D accelerometers and a respiration sensor. The collection platform has been set up by the TMSI property software Polybench, the data analysis of such signals has been performed with Matlab. The main results of this study show that the 125 Hz sampling rate has demonstrated to be a good candidate for a reliable detection of fiducial points. T wave intervals proved to be consistently stable, even at 62.5 Hz. Further studies would be needed to provide a better comparison between sampling at 250 Hz and 125 Hz for areas under the T waves.
Resumo:
In this work, a colorimetric indicator for food oxidation based on the detection of hexanal in gas-phase, has been developed. In fact, in recent years, the food packaging industry has evolved towards new generation of packaging, like active and intelligent. According to literature (Pangloli P. et al. 2002), hexanal is the main product of a fatty acid oxidation: the linoleic acid. So, it was chosen to analyse two kinds of potato chips, fried in two different oils with high concentration of linoleic acid: olive oil and sunflower oil. Five different formulas were prepared and their colour change when exposed to hexanal in gas phase was evaluated. The formulas evaluations were first conducted on filter paper labels. The next step was to select the thickener to add to the formula, in order to coat a polypropylene film, more appropriate than the filter paper for a production at industrial scale. Three kinds of thickeners were tested: a cellulose derivative, an ethylene vinyl-alcohol and a polyvinyl alcohol. To obtain the final labels with the autoadhesive layer, the polypropylene film with the selected formula and thickener was coat with a water based adhesive. For both filter paper and polypropylene labels, with and without autoadhesive layer, the detection limit and the detection time were measured. For the selected formula on filter paper labels, the stability was evaluated, when conserved on the dark or on the light, in order to determine the storage time. Both potato chips samples, stocked at the same conditions, were analysed using an optimised Headspace-Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry (HS-SPME-GC-MS) method, in order to determine the concentration of volatilized hexanal. With the aim to establish if the hexanal can be considered as an indicator of the end of potato chips shelf life, sensory evaluation was conducted each day of HS-SPME-GC-MS analysis.
Resumo:
Vision systems are powerful tools playing an increasingly important role in modern industry, to detect errors and maintain product standards. With the enlarged availability of affordable industrial cameras, computer vision algorithms have been increasingly applied in industrial manufacturing processes monitoring. Until a few years ago, industrial computer vision applications relied only on ad-hoc algorithms designed for the specific object and acquisition setup being monitored, with a strong focus on co-designing the acquisition and processing pipeline. Deep learning has overcome these limits providing greater flexibility and faster re-configuration. In this work, the process to be inspected consists in vials’ pack formation entering a freeze-dryer, which is a common scenario in pharmaceutical active ingredient packaging lines. To ensure that the machine produces proper packs, a vision system is installed at the entrance of the freeze-dryer to detect eventual anomalies with execution times compatible with the production specifications. Other constraints come from sterility and safety standards required in pharmaceutical manufacturing. This work presents an overview about the production line, with particular focus on the vision system designed, and about all trials conducted to obtain the final performance. Transfer learning, alleviating the requirement for a large number of training data, combined with data augmentation methods, consisting in the generation of synthetic images, were used to effectively increase the performances while reducing the cost of data acquisition and annotation. The proposed vision algorithm is composed by two main subtasks, designed respectively to vials counting and discrepancy detection. The first one was trained on more than 23k vials (about 300 images) and tested on 5k more (about 75 images), whereas 60 training images and 52 testing images were used for the second one.
Resumo:
The High Energy Rapid Modular Ensemble of Satellites (HERMES) is a new mission concept involving the development of a constellation of six CubeSats in low Earth orbit with new miniaturized instruments that host a hybrid Silicon Drift Detector/GAGG:Ce based system for X-ray and γ-ray detection, aiming to monitor high-energy cosmic transients, such as Gamma Ray Bursts and the electromagnetic counterparts of gravitational wave events. The HERMES constellation will also operate together with the Australian-Italian SpIRIT mission, which will house a HERMES-like detector. The HERMES pathfinder mini-constellation, consisting of six satellites plus SpIRIT, is likely to be launched in 2023. The HERMES detectors are based on the heritage of the Italian ReDSoX collaboration, with joint design and production by INFN-Trieste and Fondazione Bruno Kessler, and the involvement of several Italian research institutes and universities. An application-specific, low-noise, low-power integrated circuit (ASIC) called LYRA was conceived and designed for the HERMES readout electronics. My thesis project focuses on the ground calibrations of the first HERMES and SpIRIT flight detectors, with a performance assessment and characterization of the detectors. The first part of this work addresses measurements and experimental tests on laboratory prototypes of the HERMES detectors and their front-end electronics, while the second part is based on the design of the experimental setup for flight detector calibrations and related functional tests for data acquisition, as well as the development of the calibration software. In more detail, the calibration parameters (such as the gain of each detector channel) are determined using measurements with radioactive sources, performed at different operating temperatures between -20°C and +20°C by placing the detector in a suitable climate chamber. The final part of the thesis involves the analysis of the calibration data and a discussion of the results.
Resumo:
The aminothiols are critical cellular components that play numerous and important roles in metabolism as key extracellular reducing agents, critical substrates for proteins synthesis and detoxificants of free radicals and peroxides. Because altered thiols levels in body fluids are linked to specific pathological conditions, their measurement is thus considered very important. One method to determine these compounds is the capillary electrophoresis, a technique that involves the separation of charged molecules on the basis of their movement under the influence of an applied electric field. The instrument used in this work is equipped with an amperometric detector recording the current of the thiols oxidized at the end of the capillary at a BDD electrode. The aim of this work is to find a valid method for the separations of the aminothiols analyzed, in terms of capillary coating and experimental conditions. In order to find an alternative and less expensive electrode than BDD and to increase sensitivity for the detection of the thiols, a modified electrode consisting in a carbon paste electrode containing Cobalt-phthalocyanine has been studied. In this electrode Cobalt-phthalocyanine works as electrocatalyst to enhance the oxidation reaction, meanwhile the graphite acts as conductive mean. This kind of electrode shows great sensibility and low detection limits for the thiols that have a free thiolic group, but it is not sensible to disulfides. The analysis of human plasma point out that the best method found for the capillary electrophoresis is not useful for the detection of aminothiols in a healthy person, because the very low concentrations in which they are present.