2 resultados para hot temperature

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A way to investigate turbulence is through experiments where hot wire measurements are performed. Analysis of the in turbulence of a temperature gradient on hot wire measurements is the aim of this thesis work. Actually - to author's knowledge - this investigation is the first attempt to document, understand and ultimately correct the effect of temperature gradients on turbulence statistics. However a numerical approach is used since instantaneous temperature and streamwise velocity fields are required to evaluate this effect. A channel flow simulation at Re_tau = 180 is analyzed to make a first evaluation of the amount of error introduced by temperature gradient inside the domain. Hot wire data field is obtained processing the numerical flow field through the application of a proper version of the King's law, which connect voltage, velocity and temperature. A drift in mean streamwise velocity profile and rms is observed when temperature correction is performed by means of centerline temperature. A correct mean velocity pro�le is achieved correcting temperature through its mean value at each wall normal position, but a not negligible error is still present into rms. The key point to correct properly the sensed velocity from the hot wire is the knowledge of the instantaneous temperature field. For this purpose three correction methods are proposed. At the end a numerical simulation at Re_tau =590 is also evaluated in order to confirm the results discussed earlier.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Passive scalars measurements in turbulent pipe flows are difficult to perform and only few experimental data are available in literature. The present thesis deals with the experimental acquisition and study of the first turbulent temperature profile inside the CICLoPE wind tunnel through cold wire anemometry technique at Reτ = 6000 and Reτ = 9500. This type of measurements provides not only useful data on temperature (and passive scalars) behaviour and statistics in turbulent pipe flows, but could be used also for temperature correction of turbulent velocity profiles. In the present work, subsequent acquisitions of temperature and velocity profiles has been performed at the same Reynolds number and in the same points, through cold wire and hot wire techniques respectively. Taking as reference data from both DNS and experimental campaigns, the activity has been carried out obtaining satisfactory results. We have verified the presence of turbulent temperature profile inside the CICLoPE wind tunnel and then studied its statistical and spectral behaviours obtaining results in agreement with existing data from Hishida, Nagano, and Ferro. Cold wire temperature data were then used to correct hot wire velocity data, obtaining a slightly improvement in the near wall region.