6 resultados para heavy ion cancer therapy

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiotherapy (RT) has recently evolved with the emergence of heavy ion radiations or new fractionation schemes of photon therapy, which modify the dose rate of treatment delivery. The aim of the present study was then to evaluate the in vitro influence of a ultra-high dose rate comparing them with standard dose rate. In this regard, a radioresistant SK-MEL-28 cell line were irradiated with x-ray in order to have a total dose of 2 and 4 Gy, at two different dose rate. The ultra-high dose rate is a specific property of the dense plasma focus (DPF) device, which has pulsed operation and thus gives short and highly energetic pulses of multiple types of rays and particles, in this case, we focused our study on the influence of X-rays. While a low dose rate is obtained with conventional X-ray tube. In this study it results that a ultra-high dose rate enhances radiosensitivity of melanoma cells while reducing the adhesion, proliferation and migration ability of cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il quark-gluon plasma (QGP) è uno stato della materia previsto dalla cromodinamica quantistica. L’esperimento ALICE a LHC ha tra i suoi obbiettivi principali lo studio della materia fortemente interagente e le proprietà del QGP attraverso collisioni di ioni pesanti ultra-relativistici. Per un’esaustiva comprensione di tali proprietà, le stesse misure effettuate su sistemi collidenti più piccoli (collisioni protone-protone e protone-ione) sono necessarie come riferimento. Le recenti analisi dei dati raccolti ad ALICE hanno mostrato che la nostra comprensione dei meccanismi di adronizzazione di quark pesanti non è completa, perchè i dati ottenuti in collisioni pp e p-Pb non sono riproducibili utilizzando modelli basati sui risultati ottenuti con collisioni e+e− ed ep. Per questo motivo, nuovi modelli teorici e fenomenologici, in grado di riprodurre le misure sperimentali, sono stati proposti. Gli errori associati a queste nuove misure sperimentali al momento non permettono di verificare in maniera chiara la veridicità dei diversi modelli proposti. Nei prossimi anni sarà quindi fondamentale aumentare la precisione di tali misure sperimentali; d’altra parte, stimare il numero delle diverse specie di particelle prodotte in una collisione può essere estremamente complicato. In questa tesi, il numero di barioni Lc prodotti in un campione di dati è stato ottenuto utilizzando delle tecniche di machine learning, in grado di apprendere pattern e imparare a distinguere candidate di segnale da quelle di fondo. Si sono inoltre confrontate tre diverse implementazioni di un algoritmo di Boosted Decision Trees (BDT) e si è utilizzata quella più performante per ricostruire il barione Lc in collisioni pp raccolte dall’esperimento ALICE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of ultrarelativistic heavy-ion collisions is the investigation of the QGP. The ALICE experiment situated at the CERN has been specifically designed to study heavy-ion collisions for centre-of-mass energies up to 5.5 per nucleon pair. Extended particle identification capability is one of the main characteristics of the ALICE experiment. In the intermediate momentum region (up to 2.5 GeV/c for pi/K and 4 GeV/c for K/p), charged particles are identified in the ALICE experiment by the Time of Flight (TOF) detector. The ALICE-TOF system is a large-area detector based on the use of Multi-gap Resistive Plate Chamber (MRPC) built with high efficiency, fast response and intrinsic time resolution better than 40 ps. This thesis work, developed with the ALICE-TOF Bologna group, is part of the efforts carried out to adapt the read-out of the detector to the new requirements after the LHC Long Shutdown 2. Tests on the feasibility of a new read-out scheme for the TOF detector have been performed. In fact, the achievement of a continuous read-out also for the TOF detector would not be affordable if one considers the replacement of the TRM cards both for hardware and budget reasons. Actually, the read-out of the TOF is limited at 250 kHz i.e. it would be able to collect up to just a fourth of the maximum collision rate potentially achievable for pp interactions. In this Master’s degree thesis work, I discuss a different read-out system for the ALICE-TOF detector that allows to register all the hits at the interaction rate of 1 MHz foreseen for pp interactions after the 2020, by using the electronics currently available. Such solution would allow the ALICE-TOF detector to collect all the hits generated by pp collisions at 1 MHz interaction rate, which corresponds to an amount four times larger than that initially expected at such frequencies with the triggered read-out system operated at 250 kHz for LHC Run 3. The obtained results confirm that the proposed read-out scheme is a viable option for the ALICE TOF detector. The results also highlighted that it will be advantageous if the ALICE-TOF group also implement an online monitoring system of noisy channels to allow their deactivation in real time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The importance of pyrazole and isoquinoline-5,8-dione scaffolds in medical chemistry is underlined by the high number of drugs currently on trading that contains these active ingredients. Due to their cytotoxic capability, the interest of medicinal chemists in these heterocyclic rings has grown exponentially especially, for cancer therapy. In this project, the first synthesis of pyrazole-fused isoquinoline-5,8-diones has been developed. 1,3-Dipolar cycloaddition followed by oxidative aromatization, established by our research group, has been employed. Screening of reaction conditions and characterization studies about the regioselectivity have been successfully performed. A remote control of regioselectivity, to achieve the two possible regioisomers has been accomplished. Through Molecular Docking studies, Structure-Activity relationship of differently substituted scaffolds containing our central core proved that a family of PI3K inhibitors have been discovered. Finally, in order to verify the promising antitumor activity, a first test of cell viability in vitro on T98G cell line of a solid brain tumor, the Glioblastoma Multiforme, showed cytotoxic inhibition comparable to currently trade anticancer drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is focused on the radiation protection for a protontherapy facility. The aim is to simulate with the best accuracy the prompt radiation field of the proton accelerator situed in Ruvo di Puglia, owned by Linearbeam s.r.l. company. In order to simulate it, is used Geant4, a software for interaction simulations of particles with matter. Thanks to internship work, thesis speaks about cancer therapy with a new method for particle acceleration, a linear beam. For a complete overview of the therapy, this work starts with a crush course on interactions of particle with matter, goes specifically to biological matter, then is shown a brief introduction to shielding studies for a particle acceleration facility, and then a presentation of Geant4. At the end, the main aspects of the proton accelerator are simulated, from proton hitting material of beam-pipe to detectors used to measure dose.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

La radioterapia guidata da immagini (IGRT), grazie alle ripetute verifiche della posizione del paziente e della localizzazione del volume bersaglio, si è recentemente affermata come nuovo paradigma nella radioterapia, avendo migliorato radicalmente l’accuratezza nella somministrazione di dose a scopo terapeutico. Una promettente tecnica nel campo dell’IGRT è rappresentata dalla tomografia computerizzata a fascio conico (CBCT). La CBCT a kilovoltaggio, consente di fornire un’accurata mappatura tridimensionale dell’anatomia del paziente, in fase di pianificazione del trattamento e a ogni frazione del medisimo. Tuttavia, la dose da imaging attribuibile alle ripetute scansioni è diventata, negli ultimi anni, oggetto di una crescente preoccupazione nel contesto clinico. Lo scopo di questo lavoro è di valutare quantitativamente la dose addizionale somministrata da CBCT a kilovoltaggio, con riferimento a tre tipici protocolli di scansione per Varian OnBoard Imaging Systems (OBI, Palo Alto, California). A questo scopo sono state condotte simulazioni con codici Monte Carlo per il calcolo della dose, utilizzando il pacchetto gCTD, sviluppato sull’architettura della scheda grafica. L’utilizzo della GPU per sistemi server di calcolo ha permesso di raggiungere alte efficienze computazionali, accelerando le simulazioni Monte Carlo fino a raggiungere tempi di calcolo di ~1 min per un caso tipico. Inizialmente sono state condotte misure sperimentali di dose su un fantoccio d’acqua. I parametri necessari per la modellazione della sorgente di raggi X nel codice gCTD sono stati ottenuti attraverso un processo di validazione del codice al fine di accordare i valori di dose simulati in acqua con le misure nel fantoccio. Lo studio si concentra su cinquanta pazienti sottoposti a cicli di radioterapia a intensità modulata (IMRT). Venticinque pazienti con tumore al cervello sono utilizzati per studiare la dose nel protocollo standard-dose head e venticinque pazienti con tumore alla prostata sono selezionati per studiare la dose nei protocolli pelvis e pelvis spotlight. La dose media a ogni organo è calcolata. La dose media al 2% dei voxels con i valori più alti di dose è inoltre computata per ogni organo, al fine di caratterizzare l’omogeneità spaziale della distribuzione.